INTRODUCTION

Thank you for purchasing this model by Generac Power Systems, 

Inc.  This model is a compact, high performance, air-cooled, 

engine driven generator designed to supply electrical power to 

operate electrical loads where no utility power is available or in 

place of utility due to a power outage.

READ THIS MANUAL THOROUGHLY

If any portion of this manual is not understood, contact the 

nearest Authorized Dealer for starting, operating and servicing 

procedures.
The operator is responsible for proper and safe use of the 

equipment. We strongly recommend that the operator read this 

manual and thoroughly understand all instructions before using the 

equipment. We also strongly recommend instructing other users to 

properly start and operate the unit. This prepares them if they need 

to operate the equipment in an emergency.
The generator can operate safely, efficiently and reliably only if it 

is properly located, operated and maintained. Before operating or 

servicing the generator:

Become familiar with and strictly adhere to all local, state and 

• 

national codes and regulations.

Study all safety warnings in this manual and on the product 

• 

carefully.

Become familiar with this manual and the unit before use.

• 
The manufacturer cannot anticipate every possible circumstance 

that might involve a hazard. The warnings in this manual, and on 

tags and decals affixed to the unit are, therefore, not all inclusive. 

If using a procedure, work method or operating technique that the 

manufacturer does not specifically recommend, ensure that it is 

safe for others. Also make sure the procedure, work method or 

operating technique utilized does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON 

MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. 

GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT 

ANY TIME. 

SAFETY RULES

Throughout this publication, and on tags and decals affixed to the 

generator, DANGER, WARNING, CAUTION and NOTE blocks are 

used to alert personnel to special instructions about a particular 

operation that may be hazardous if performed incorrectly or 

carelessly. Observe them carefully. Their definitions are as 

follows:

INDICATES A HAZARDOUS SITUATION OR ACTION WHICH, IF 

NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.

Indicates a hazardous situation or action which, if not 

avoided, could result in death or serious injury.

Indicates a hazardous situation or action which, if not 

avoided, could result in minor or moderate injury.

NOTE:

Notes contain additional information important to a procedure 

and will be found within the regular text body of this manual.

These safety warnings cannot eliminate the hazards that they 

indicate. Common sense and strict compliance with the special 

instructions while performing the action or service are essential to 

preventing accidents.
Four commonly used safety symbols accompany the 

DANGER

WARNING

 and 

CAUTION

 blocks. The type of information each 

indicates is as follows:

 This symbol points out important safety information 

that, if not followed, could endanger personal safety 

and/or property of others.
This symbol points out potential explosion hazard.

This symbol points out potential fire hazard.

This symbol points out potential electrical shock hazard.

GENERAL HAZARDS

Never operate in an enclosed area or indoors. 

• 

For safety reasons, the manufacturer recommends that the 

• 

maintenance of this equipment is carried out by an Authorized 

Dealer. Inspect the generator regularly, and contact the nearest 

Authorized Dealer for parts needing repair or replacement.

Operate generator only on level surfaces and where it will not be 

• 

exposed to excessive moisture, dirt, dust or corrosive vapors.

Keep hands, feet, clothing, etc., away from drive belts, fans, 

• 

and other moving parts. Never remove any fan guard or shield 

while the unit is operating.

Certain parts of the generator get extremely hot during 

• 

operation. Keep clear of the generator until it has cooled to 

avoid severe burns.

Do NOT operate generator in the rain.

• 

Do not alter the construction of the generator or change controls 

• 

which might create an unsafe operating condition.

Never start or stop the unit with electrical loads connected 

• 

to receptacles AND with connected devices turned ON. Start 

the engine and let it stabilize before connecting electrical 

loads. Disconnect all electrical loads before shutting down the 

generator.

Do not insert objects through unit’s cooling slots.

• 

When working on this equipment, remain alert at all times. 

• 

Never work on the equipment when physically or mentally 

fatigued.

Never use the generator or any of its parts as a step. Stepping 

• 

on the unit can stress and break parts, and may result in 

dangerous operating conditions from leaking exhaust gases, 

fuel leakage, oil leakage, etc.

On electric start models, disconnect the POSITIVE (+) Battery 

• 

cable from the engine starter OR the NEGATIVE (-) Battery 

cable from the battery terminal, whichever is easier, before 

transporting the generator. 

1

Содержание iX 2000

Страница 1: ...MODEL 005793 0 iX 2000 Digital Inverter Generator Operator s Manual ...

Страница 2: ...ling the Generator 7 To Fill the Fuel Tank 8 Adding Engine Oil 8 To Add Engine Oil to the Crankcase 8 Section 3 Maintenance 8 Generator Maintenance 8 Generator Maintenance Schedule 9 Cleaning the Generator 9 Engine Maintenance 9 Changing the Engine Oil 9 Changing the Fuel Filter 10 Changing the Spark Plug 10 Transportation and Storage 10 Section 4 Troubleshooting 11 Troubleshooting Guide 11 Sectio...

Страница 3: ...es a hazardous situation or action which if not avoided could result in minor or moderate injury NOTE Notes contain additional information important to a procedure and will be found within the regular text body of this manual These safety warnings cannot eliminate the hazards that they indicate Common sense and strict compliance with the special instructions while performing the action or service ...

Страница 4: ...oot or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for grounding requirements in the area Use a ground fault ci...

Страница 5: ... the latest revision available for the standards listed 1 NFPA No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE 2 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDB...

Страница 6: ...les 7 Air Intake Slats Allows for cooling air to enter the housing 8 Muffler Lowers engine exhaust noise 9 Choke Cold engine starting aid 10 Left Side Service Cover Allows access to air filter fuel filter and oil fill dipstick 11 Vent Hoses Hoses allow venting of the crankcase and carburetor 12 Fuel Shutoff Controls fuel supply to the carburetor 13 Starter Rope Pull rope for starting engine Figure...

Страница 7: ...e service cover 5 Make sure there are no loads connected to the generator 6 The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Proper grounding of the generator will prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices Proper ...

Страница 8: ...to the generator 3 Consult the following table to estimate what can be powered by the generator Device Running Watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charger 20 Amp 500 Belt Sander 3 1000 Chain Saw 1200 Circular Saw 6 1 2 800 to 1000 Clothes Dryer Electric 5750 Clothes Dryer Gas 700 Clothes Washer 1150 Coffee Maker 1750 Compres...

Страница 9: ... generator Unplug any cords to the 120 VAC duplex outlets 2 Turn the fuel valve to the OFF O position Figure 7 A switch behind the fuel valve grounds the ignition system stopping the engine and the fuel supply is shut off 3 Allow the generator to cool before moving or storing Always allow the generator to cool off before storing High temperatures will be present at the rear of the unit for some ti...

Страница 10: ...stick located on the bottom of the engine crankcase 4 Add the recommended engine oil slowly stopping frequently to check the level The full level is the base of the threads in the filler neck 5 Replace the oil fill cap dipstick and tighten 6 Always check the oil level before starting the generator engine DO NOT overfill the engine crankcase with oil High oil pressure may result causing premature e...

Страница 11: ... on a generator that has cooled completely Inspect the oil level and air filter condition each time you are going to use the generator To check the air filter and oil level the left side service cover must be removed use a screwdriver to loosen the screw securing the cover and remove The air filter is located behind a cover for the air box Figure 10 Push the tab on the bottom of the air box up war...

Страница 12: ...d 5 Replace the spark plug cover Figure 12 Replace Spark Plug SPARK PLUG LOCATION TRANSPORTATION AND STORAGE Transport or store the generator only if it has cooled completely Make sure the fuel valve and the vent on the fuel cap are both in the OFF O position It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor fuel hose or tank during long ter...

Страница 13: ...level add as needed 4 Replace fuel filter 5 Replace engine start switch 6 Replace ignition coil Engine starts then runs rough 1 Choke is stuck or left on 2 Dirty or clogged air filter 3 Defective spark plug 4 Dirty fuel filter 5 Defective FlexPower switch 1 Turn choke off 2 Clean or replace the air filter element 3 Replace spark plug 4 Replace fuel filter 5 Replace FlexPower switch No AC output 1 ...

Страница 14: ...c You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Dealer To locate the Generac Authorized Warranty Service Dealer nearest you call our toll...

Страница 15: ...uled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part 4 Repair or replacement of any war...

Страница 16: ... any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Systems Failures due but not limited to normal wear and tear accident misuse abuse negligence or improper use As with all mechanical devices the Generac engines need periodic part s service and replacemen...