Section 6
TROUBLESHOOTING FLOWCHARTS
Page 31
CLEAN AND REGAP OR
REPLACE SPARK PLUG
REPLACE
BAD
SWITCH
REPAIR OR
REPLACE
REPLACE MAGNETOS
ADJUST VALVES
REPLENISH FUEL SUPPLY
O.K.
Problem 7 – Engine Cranks But Will Not Start (LP Units)
(Overcrank Warning Code on SW1 LED – 3 Flashes)
BAD
BAD
BAD
REPAIR OR REPLACE
AS NECESSARY
BAD
BAD
BAD
GOOD
GOOD
GOOD
GOOD
GOOD
GOOD
TEST 26 – CHECK
WIRE 14 POWER
SUPPLY
TEST 20 – CHECK
START-STOP
SWITCH
TEST 25 –
CHECK FUEL
SUPPLY
TEST 41 – CHECK
LPG FUEL
SOLENOID
TEST 29 –
CHECK
IGNITION
SPARK
TEST 31 – CHECK
AND ADJUST
IGNITION
MAGNETOS
TEST 30 –
CHECK SPARK
PLUG
TEST 32 – CHECK
VALVE
ADJUSTMENT
TEST 35 – CHECK
ENGINE / CYLINDER
LEAK DOWN TEST /
COMPRESSION TEST
CHECK
FLYWHEEL KEY
– SEE TEST 31
ON PAGE 57
LOW LP PRESSURE
WEAK SPARK / NO SPARK /
INTERMITTENT SPARK
NO START
REPLACE
PRINTED CIRCUIT
BOARD
Содержание Guardian 5410
Страница 66: ...Section 9 Exploded Views Page 64 Base Pulley Drawing No 0G7720 B...
Страница 68: ...Page 66 Enclosure Drawing No 0G3881 C Section 9 Exploded Views...
Страница 72: ...Page 70 Engine Accessories Drawing No 0G7718 B Section 9 Exploded Views...
Страница 80: ...Section 11 ELECTRICAL DATA Page 78 Electrical Schematic and Wiring Diagram Drawing No 0G4221 B...
Страница 81: ...Section 11 ELECTRICAL DATA Page 79 Electrical Schematic and Wiring Diagram Drawing No 0G4221 B...
Страница 82: ...PO Box 297 Whitewater WI 53190 www guardiangenerators com P N OG7515 REV A PRINTED IN THE USA 03 08...