Generac Power Systems Guardian 04389-2 Скачать руководство пользователя страница 2

Generac

®

Power Systems, Inc.

INTRODUCTION

Thank you for purchasing this model of the Guardian
product line by Generac Power Systems Inc. This
model is a compact, high performance, air-cooled,
engine-driven generator designed to automatically
supply electrical power to operate critical loads dur-
ing a utility power failure.

This unit is factory installed in an all-weather, metal enclo-
sure that is intended exclusively for outdoor installation.
This generator will operate using either vapor withdrawn
liquid propane (LP) or natural gas (NG).

READ THIS MANUAL THOROUGHLY

If any portion of this manual is not understood, contact
Generac or the nearest Generac/Guardian Authorized
Dealer for starting, operating and servicing procedures.

Throughout this publication, and on tags and 
decals affixed to the generator, DANGER, WARNING,
CAUTION and NOTE blocks are used to alert per-
sonnel to special instructions about a particular
operation that may be hazardous if performed incor-
rectly or carelessly. Observe them carefully. Their def-
initions are as follows:

After this heading, read instructions that, if not
strictly complied with, will result in serious person-
al injury, including death, in addition to property
damage.

After this heading, read instructions that, if not
strictly complied with, may result in serious person-
al injury or property damage.

After this heading, read instructions that, if not
strictly complied with, could result in damage to
equipment and/or property.

NOTE:

After this heading, read explanatory statements
that require special emphasis.

These safety warnings cannot eliminate the hazards
that they indicate. Common sense and strict compli-
ance with the special instructions while performing the
service are essential to preventing accidents.

Four commonly used safety symbols accompany the
DANGER, WARNING and CAUTION blocks. The type
of information each indicates follows:

This symbol points out important safety informa-
tion that, if not followed, could endanger personal
safety and/or property of others.

This symbol points out potential explosion hazard.

This symbol points out potential fire hazard.

This symbol points out potential electrical shock
hazard.

The operator is responsible for proper and safe use 
of the equipment. Generac strongly recommends that
the operator read this 

Owner's Manual

and thor-

oughly understand all instructions before using this
equipment. Generac also strongly recommends
instructing other users to properly start and operate
the unit. This prepares them if they need to operate
the equipment in an emergency.

CONTENTS

This manual contains pertinent owner’s information,
including warranty, electrical diagrams, exploded
views and lists of repair parts, for three different
Guardian models:
• 04389-2 – 6 kW NG, 7 kW LP, single-cylinder GH-

410 Engine

• 04456-2 – 12 kW NG, 12 kW LP, V-twin GT-990

Engine

• 04390-2 – 13 kW NG, 15 kW LP, V-twin GT-990

Engine

OPERATION AND MAINTENANCE

It is the operator's responsibility to perform all safe-
ty checks, to make sure that all maintenance for safe
operation is performed promptly, and to have the
equipment checked periodically by a Generac/
Guardian Authorized Dealer. Normal maintenance
service and replacement of parts are the responsibil-
ity of the owner/operator and, as such, are not con-
sidered defects in materials or workmanship within
the terms of the warranty. Individual operating habits
and usage contribute to the need for maintenance
service.

Proper maintenance and care of the generator
ensures a minimum number of problems and keep
operating expenses at a minimum. See a Generac/
Guardian Authorized Dealer for service aids and
accessories.

HOW TO OBTAIN SERVICE

When the generator requires servicing or repairs,
simply contact a Generac/Guardian Authorized
Dealer for assistance. Service technicians are factory-
trained and are capable of handling all service needs.

When contacting a Generac/Guardian Authorized
Dealer or the factory about parts and service, always
supply the complete model number and serial number
of the unit as given on its data decal, which is located
on the generator. See Figure 1.1 or Figure 1.2 in
Section 1.6 for decal location.

Model No. ____________ Serial No. ______________

‹

‹

‹

!

DANGER

‹

AUTHORIZED

DEALER LOCATION

To locate the nearest GENERAC/GUARDIAN

AUTHORIZED DEALER, please call this number:

1-800-333-1322

DEALER LOCATION INFORMATION 

CAN BE OBTAINED AT THIS NUMBER.

Содержание Guardian 04389-2

Страница 1: ...ed Prepackaged Automatic Standby Generators Models 04389 2 6 kW NG 7 kW LP 04456 2 12 kW NG 12 kW LP 04390 2 13 kW NG 15 kW LP DEADLY EXHAUST FUMES OUTDOOR INSTALLATION ONLY DANGER Not intended for us...

Страница 2: ...potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment Generac strongly recommends that the operator read...

Страница 3: ...or Tests Under Load 11 2 5 Checking Automatic Operation 11 2 6 Adjusting the Regulator Natural Gas Only 12 2 7 Engine Governor Adjustment 13 2 8 Voltage Regulator Adjustment 13 Section 3 Operation 14...

Страница 4: ...y in strict compli ance with applicable codes and standards Following installation do nothing that might ren der the system unsafe or in noncompliance with such codes and standards Keep hands feet clo...

Страница 5: ...talled in accordance with the manufacturer s instructions and recommendations Following proper installa tion do nothing that might alter a safe installation and render the unit in noncompliance with t...

Страница 6: ...anel to noti fy personnel that one of these faults has occurred There is also a System Set LED that is lit when all of the conditions describe in Section 1 3 are true 1 3 NEC REQUIREMENT FOR ARC FAULT...

Страница 7: ...Panel Battery Compartment Fuel Inlet Air Filter Exhaust Enclosure Oil Filter Data Decal Fuel Regulator Oil Check Fill Control Panel Air Filter Exhaust Enclosure Battery Compartment Fuel Inlet Oil Filt...

Страница 8: ...tude engine power and condition etc Maximum power decreases about 3 5 percent for each 1 000 feet above sea level and also will decrease about 1 percent for each 6 C 10 F above 16 C 60 F ambient tempe...

Страница 9: ...sure proper gas pressure 11 14 to the gen erator Low gas pressure can cause hard starting and could affect engine durability 1 8 FUEL CONSUMPTION Natural gas is in cubic feet per hour LP is in gallons...

Страница 10: ...P fuel turn the adjuster screw that can be accessed from inside the front of the unit TURN CLOCKWISE This should now set the system for maximum power and best performance 14 It may be necessary to mak...

Страница 11: ...battery installed and utility power source voltage available to the transfer switch the battery receives a trickle charge while the engine is not running to prevent self discharge The trickle charger...

Страница 12: ...rn OFF the utility power supply to the transfer switch using the means provided such as the utility main line circuit breaker 4 Turn OFF all loads connected to the transfer switch terminals T1 and T2...

Страница 13: ...e means provided such as a util ity main line circuit breaker Do not attempt manual transfer switch opera tion until all power voltage supplies to the transfer switch have been positively turned off F...

Страница 14: ...enerator confirm that the No Load Frequency with the roof open and door off is set to 63 63 5 Hz Transfer load to emergency circuits 3 Turn on appliances lights pumps etc that are on the emergency cir...

Страница 15: ...Engine Governor Adjustment 2 7 2 12 KW AND 15 KW UNITS 1 Loosen governor clamp bolt See Figure 2 3 2 Completely remove the idle spring 3 With governor arm at wide open throttle position rotate govern...

Страница 16: ...ce the oil with synthetic oil as recommended in Section 4 3 Changing the Engine Oil 13 Reconnect the battery cables as outlined in General Hazards page 2 and insert the 5A and 15A fuses into the gener...

Страница 17: ...tage has reached 50 percent of the nominal rated voltage transfer to standby can occur D Utility Voltage Pickup Sensor This sensor monitors utility power supply volt age When that voltage is restored...

Страница 18: ...AUTO OFF MANUAL switch is set to AUTO 2 Hold down the Set Exercise Time switch until the generator starts approximately 10 seconds and then release 3 The generator will start and run for approximate...

Страница 19: ...ap down and rotate counterclockwise Figure 4 1 Generator Control Panel 4 2 CHECKING THE ENGINE OIL LEVEL For oil capacities see Specifications Section 1 5 For engine oil recommendations see Section 4...

Страница 20: ...e the engine oil filter as follows 1 With the oil drained remove the old oil filter by turning it counterclockwise 2 Apply a light coating of clean engine oil to the gas ket of the new filter See Sect...

Страница 21: ...battery in a fire The battery is capable of exploding A battery presents a risk of electrical shock and high short circuit current The following precautions are to be observed when working on batteri...

Страница 22: ...creen at the front of the engine to gain access to the flywheel nut Use a large socket and socket wrench to rotate the nut and hence the engine While watching the piston through the spark plug hole Th...

Страница 23: ...ag to the engine indicating the viscosity and classification of the oil in the crankcase 8 Remove the spark plug s and spray fogging agent into the spark plug s threaded openings Reinstall and tighten...

Страница 24: ...aler Y Yearly if Repair is Needed FUEL Fuel lines and connections X M LUBRICATION Oil level X M Oil X AFTER BREAK IN AND Y Oil filter X AFTER BREAK IN AND Y COOLING Enclosure louvers X X W BATTERY Rem...

Страница 25: ...r plugged 1 Check replace air cleaner and runs rough or damaged 2 Defective spark plug s 2 Clean re gap or replace plug s 3 Fuel Regulator not set 3 Set Fuel Regulator 4 Fuel Pressure incorrect 4 Conf...

Страница 26: ...O OFF MANUAL SWITCH LOP LOW OIL PRESSURE SWITCH IM2 IGNITION MODULE CYLINDER 2 IM1 IGNITION MODULE CYLINDER 1 SCR STARTER CONTACTOR RELAY FS FUEL SOLENOID SP1 SP2 SPARK PLUGS SC STARTER CONTACTOR IC I...

Страница 27: ...7 VOLTAGE REGULATOR 15A 23 13 351 13 13 13A 13 13 0 0 N2 N1 351 0 66A 4 162 0 4 6 0 4 162 6 239 AUTO SW1 1 1b 1a SW2 CONNECTION CUSTOMER SWITCH CONTACTOR 240V GENERATOR 0 CB1 23 N1 N2 194 351 66A 55 7...

Страница 28: ...CHARGE RELAY DIAGRAM KEY SC STARTER CONTACTER 2 1 5 3 4 J2 2 1 3 2 1 14 16 17 12 10 9 J1 7 5 3 2 1 F2 FUSE 5 AMP BA BRUSH ASSEMBLY CB2 CIRCUIT BREAKER ALT EXCITATION D DIODE SCR STARTER CONTACTOR RELA...

Страница 29: ...IM1 0 194 17 15 23 15 239 SW1 194 15A 22 11 23 11 22 11 SP1 44 WINDING 120V 120V 33 NEUTRAL N2 N1 23 CUSTOMER CONNECTIONS 194 0 0 SC FS 16 14 BATTERY CUSTOMER SUPPLIED SM 12V SC N2 N1 13 TX 56VA 1VA C...

Страница 30: ...TEMPERATURE SWITCH GRD CONTROL PANEL GROUND FS FUEL SOLENOID SW1 AUTO OFF MANUAL SWITCH LOP LOW OIL PRESSURE SWITCH IM IGNITION MODULE F2 FUSE 5 AMP F1 FUSE 15 AMP SP SPARK PLUG TB INSULATED TERMINAL...

Страница 31: ...0 13 F1 13 351 14 N2 0 224 225 0 351 13 224 4 0 225 14 N2 N1 13A N1 VOLTAGE REGULATOR 0 66A 0 162 22 0 4 6 11 4 4 11 22 4 MANUAL AUTO 17 15 SW1 239 SW2 CONNECTION CUSTOMER 0 351 CB1 11 66 N1 194 0 23...

Страница 32: ...STARTER CONTACTER SW2 SET EXERCISE SWITCH SM STARTER MOTOR LOP LOW OIL PRESSURE SWITCH D DIODE DIAGRAM KEY 2 1 10 17 16 15 12 11 13 J1 5 3 J2 4 6 8 3 5 4 1 3 1 2 2 1 DPE WINDING 0 VOLTAGE REGULATOR E...

Страница 33: ...ITY COIL RELAY TRANSFER NEUTRAL 120V 240VAC CUSTOMER SUPPLIED 23 SW1 239 C1 6 0 15 17 0 18 C1 5 0 18 0 17 56 18 14 15A 17 0 15 0 C1 1 56 239 13 15 SC 14 15A 194 23 15 IM 0 D BLACK SP POWER WINDING STA...

Страница 34: ...27 35 1 49 49 49 11 50 16 17 1 5 47 19 12 6 31 44 30 29 28 87 86 41 40 55 57 56 58 52 49 20 52 72 60 44 62 64 66 59 71 69 68 71 68 69 38 73 75 46 74 76 82 77 80 82 79 80 81 48 44 85 84 72 91 63 92 49...

Страница 35: ...NO QTY DESCRIPTION 42 0D3037A 1 LATCH QUARTER TURN NON LOCKING 43 0A2115 4 WASHER NYLON 250 44 022097 9 WASHER LOCK M6 1 4 45 022473 4 WASHER FLAT ZINC 46 036261 14 RIVET POP 125 X 129 133 30 47 04741...

Страница 36: ...10 13 15 35 17 49 14 15 5 16 23 38 45 48 2 29 21 17 16 4 6 7 49 23 27 42 12 45 44 20 40 11 1 43 15 35 14 3 41 24 45 47 47 45 31 33 14 13 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7...

Страница 37: ...40 1 SWITCH SPST ON ON N O 23 051714 4 NUT HEX M3 0 5 8 5KW 12KW 13KW ITEM PART NO QTY DESCRIPTION 051714 2 NUT HEX M3 0 5 7KW 24 0D8502 1 NEUTRAL CONNECTOR 26 0D8441 1 HARNESS CONTROL PANEL NOT SHOWN...

Страница 38: ...9 22 22 21 16 23 24 10 31 7 9 17 18 6 11 5 3 2 33 20 36 19 25 15 4 32 34 34 35 12 26 14 8 13 3B 3A Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW Generators 7 kW GTS...

Страница 39: ...8GP 16 022152 6 WASHER LOCK 10 17 087680 1 NUT WING M6 1 0 18 077441 1 HANDLE TRANSFER SWITCH HOME STANDBY 19 063378 4 HOLDER CABLE TIE 20 0A2110 4 SCREW SWAGE 1 4 20 X 1 2 ZINC 21 074138 2 LUG QUICK...

Страница 40: ...1 16 23 24 10 31 7 9 17 18 6 11 5 3 2 39 26 36 19 25 15 38 33 32 34 34 20 37 12 14 8 13 3B 3A 38 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW Generators 12 kW and...

Страница 41: ...RANSFER SWITCH HOME STANDBY 19 063378 4 HOLDER CABLE TIE 20 0D3094 1 HARNESS GTS TO MAIN PANEL 21 074138 2 LUG QUICK DISCONNECT NI S 10X45 DEG BRASS TIN 22 036933 6 SCREW PPHM 10 32 X 3 8 23 077033 6...

Страница 42: ...51 50 49 48 47 46 45 44 43 57 1 42 41 38 37 36 35 34 33 39 3 40 2 3 26 10 4 34 25 11 30 20 66 2 5 19 20 39 40 47 64 93 140 3 32 33 34 35 36 40 72 73 140 16A 16B 16A 54 53 56 Section 7 Exploded Views a...

Страница 43: ...TUBE 33 0D1667 1 ARM GOVERNOR 34 0C2991 2 E RING GOVERNOR ARM 35 0C2988 1 THRUST WASHER GOVERNOR ITEM PART NO QTY DESCRIPTION 36 0C2992 1 BUSHING GOVERNOR LOWER 37 0C3971C 1 ASSEMBLY DIPSTICK WITH HA...

Страница 44: ...83 84 82 81 130 99 118 126 94 79 78 76 77 75 74 122 125 123 125 119 120 137 136 134 133 132 127 29 135 113 101 110 121 112 128 124 24 80 87 98 97 138 139 11 116 141 Section 7 Exploded Views and Parts...

Страница 45: ...8 107 0C3033 1 WASHER 25mm I D 108 0C3034 1 NUT HEX M24 ITEM PART NO QTY DESCRIPTION 109 0C8549 1 SNORKEL AIR INTAKE 110 0C3022A 1 HOUSING BLOWER NG COOLER 111 0D1131 1 GUARD FAN 112 045756 27 SCREW...

Страница 46: ...31 31 12 5 22 14 20 38 15 30 24 26 32 10 19 16 28 27 17 10 1 28 31 32 17 32 31 33 28 13 39 18 40 28 34 35 34 44 48 30 45 46 34 36 47 52 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7...

Страница 47: ...8 X 1 2 23 049451 1 WASHER FLAT 406ID X 1 62OD 24 022237 4 WASHER LOCK 3 8 25 022511 4 BOLT HHC 3 8 16 X 1 1 4 G5 26 022131 4 WASHER FLAT 3 8 ZINC 27 039287 4 SCREW HHC M8 1 25 X 45 G8 8 28 022145 14...

Страница 48: ...38 17 32 31 28 31 20 19 10 17 15 32 16 22 39 8 6 37 14 3 2 40 32 24 25 10 30 19 26 28 27 28 32 31 41 10 18 36 35 29 41 42 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 1...

Страница 49: ...BER MOUNT 18 0388050AD0 1 CABLE 6 48 BLACK BATTERY 19 0C2417A 1 EARTH STRAP 3 8X 3 8 20 082121C 1 CLIP J VYNL COAT 0 625 ID 21 066386 1 ASSEMBLY BRUSH HOLDER 22 029451 2 6 FT TAPE ELEC UL FOAM 1 8 X 1...

Страница 50: ...3 39 18 19 20 23 32 44 48 24 46 11 22 29 28 31 30 17 52 1 14 13 26 38 25 25 40 41 12 16 6 1 2 4 42 10 5 7 3 8 9 49 51 50 54 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and...

Страница 51: ...12 THK 26 0C7393 1 BALANCER 27 021714 1 ASSEMBLY CYLINDER HEAD SEATS GUIDES 28 086516 1 VALVE EXHAUST 29 086517 1 VALVE INTAKE 30 0D9853B 2 PUSH ROD 174 9 31 083897 2 TAPPET 32 077158 1 ASSEMBLY SCREE...

Страница 52: ...0 28 3 39 40 41 43 44 2 4 6 5 12 7 8 9 10 13 14 1 16 18 11 6 37 36 35 27 17 18 34 33 34 18 29 30 31 38 6 45 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW Generators...

Страница 53: ...25 X 30 G12 9 22 099236 1 SWITCH OIL 8 0 PSI 23 070185 1 FILTER OIL DIA 69 X 64 LG 24 082774 1 KEY WOODRFF 4 X 19D 25 091222E 1 FLYWHEEL WITH RING GEAR 32DEG 26 067198N 1 WASHER BELV 20 X 2 2 27 06789...

Страница 54: ...22 0C6731 2 RIVET POP 118 X 125 23 0C6067 2 SUPPORT DIAPHRAGM 24 0C4706 2 DIAPHRAGM TWIN REGULATOR 25 0C6068 2 CAP DIAPHRAGM SUPPORT 26 0C4643A 2 INLET TWIN REGULATOR 11 11 DIA 27 026073 1 PLUG STANDA...

Страница 55: ...AIR NTAKE IF SUPPLIED DO NOT LIFT BY THE ROOF LIFTING HOLES 4 CORNERS 30 2mm 1 19 ROUNDING LUG 3 4 NPT FUEL INLET GAS PRESSURE OF 11 14 WATER COLUMN REQUIRED ALL DIMENSIONS IN MILLIMETERS INCHES 76 2m...

Страница 56: ...54 Generac Power Systems Inc Section 9 Notes Guardian Air cooled 7 kW 12 kW and 15 kW Generators...

Страница 57: ...Generac Power Systems Inc 55 Section 9 Notes Guardian Air cooled 7 kW 12 kW and 15 kW Generators...

Страница 58: ...eglect improper maintenance or unap proved modifications or the use of counterfeit and or grey market parts not made supplied or approved by Generac You are responsible for contacting a Generac Author...

Страница 59: ...ction 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point...

Страница 60: ...use abuse negligence or improper installation As with all mechanical devices the Generac engines need periodic part s service and replacement to perform well This warranty will not cover repair when n...

Отзывы: