General Information
6
Owner’s Manual for 7.5 kW PowerPact™
Specifications
Generator
Engine
The specification sheet for your generator was included in the documentation provided with the unit at the time of
purchase. For additional copies, consult your local Independent Authorized Service Dealer for your specific generator
model.
Model
7.5 kW
Rated Voltage
240
Rated Maximum Load Current
(Amps) at 220 Volts (LP)*
31.25
Main Circuit Breaker
35 Amp
Phase
1
Rated AC Frequency
60 Hz
Battery Requirement
Group U1, 12 Volts and 300 CCA Minimum (see
)
Enclosure
Galvanneal Steel
Unit Weight
280 lb (127.3 kg)
Normal Operating Range
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 ºF (-29
ºC) to 122 ºF (50 ºC). For areas where temperatures fall below 32 ºF (0 ºC) a cold weather kit is
recommended. When operated above 77 ºF (25 ºC) there may be a decrease in engine power.
(Please reference the engine specifications section.)
These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
* Natural Gas ratings will depend on specific fuel joules/Btu content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the
transfer switch.
Model
7.5 kW
Type of Engine
GA-420
Number of Cylinders
1
Displacement
25.6 in
3
(420 cc)
Cylinder Block
Aluminum w/ cast iron sleeve
Recommended Spark Plug
see
Spark Plug Gap
0.030 in (0.76 mm)
Valve Clearance
0.002 - 0.004 in
(0.05 - 0.1 mm)
Starter
12 VDC
Oil Capacity
Approx. 1.2 qt (1.1 L)
Recommended Air Filter
see
Engine power is subject to and limited by such factors as fuel Btu/joules, ambient temperature and altitude. Engine power decreases about 3.5 percent
for each 1000 feet (304.8 meters) above sea level, and also will decrease about 1 percent for each 10 °F (6 ºC) above 60 ºF (15 ºC) ambient temperature.
Содержание G0069980
Страница 4: ...Table of Contents iv Owner s Manual for 7 5 kW PowerPact This page intentionally left blank...
Страница 18: ...Operation 14 Owner s Manual for 7 5 kW PowerPact This page intentionally left blank...
Страница 28: ...Troubleshooting 24 Owner s Manual for 7 5 kW PowerPact This page intentionally left blank...
Страница 31: ......
Страница 63: ......
Страница 95: ......