Daily Walk-Around Inspection

Perform  a  walk-around  inspection  of  the  unit  every  day
before  starting  the  unit.  Look  for  conditions  that  could
hinder performance or safety, such as (but not limited to)
damaged  or  missing  parts  and  hardware,  and  loose  or
broken electrical connections.

General Maintenance

Poorly  maintained  equipment  can  become  a  safety
hazard. In order for the equipment to operate safely and
properly over a long period of time, periodic maintenance
and occasional repairs are necessary. 

DO NOT

 perform

routine service unless all electrical components are OFF. 
Regular  maintenance  will  improve  performance  and
extend  engine/equipment  life.  Generac  Mobile  Products
LLC recommends all maintenance work be performed by
a Generac Mobile Products Authorized Dealer (ASD).

Inspecting the Unit

If the unit is stored outside, check for water inside
the  cabinet  and  control  panel  cover  before  each
use. If wet, dry the unit thoroughly before starting.

Inspect condition of electrical cords. 

DO NOT

 use

the unit if insulation is cut or worn through.

Verify  the  wheels  and  locking  caster  are  present
and in serviceable condition.

Preparing for Service

Before  servicing  the  unit,  always  follow  the  instructions
listed below.

1.

Verify unit power switch is OFF.

2.

Disconnect shore power from the unit.

3.

Disconnect water supply from the unit.

4.

Attach  a  DO  NOT  USE  sign  to  the  control  panel.
This  will  notify  everyone  that  the  unit  is  being
serviced  and  will  reduce  the  chance  of  someone
inadvertently trying to start the unit.

Cleaning the Unit

See 

Figure 4-1

After  each  use, clean  nozzles  (A)  with a

water solution and antilimestone product. 

Figure 4-1. Cleaning the Unit 

Always  clean  the  unit  after  each  use  to  remove  dust,
grease, mud, or spilled fuel or oil. Use soft, clean rags to
wipe the cabinet exterior and control panel. Low-pressure
compressed air (less than 40 PSI [276 kPa]) can also be
used to remove dust and debris from the cabinet interior.
This  unit  contains  sensitive  electronic  components  that
can  be  damaged  by  high  pressure,  heat  and  moisture.
Do not wash the unit with a high pressure hose or power
washer.  Water  may  enter  the  cabinet  and  collect  in  the
control panel or other electrical parts, causing damage. 

M

Maintenance   

Activity

After First 
Operation

Before 

Each Use

Semi-

Annually

Check all electrical 
connections

Clean Inlet Filter

Clean Nozzles

WARNING

(000586)

Before servicing unit, shut unit down, turn water supply 
OFF, and disconnect unit from power source. Failure 
to do so could result in death, serious injury, or 
equipment damage.

 

CAUTION

(000306)

Equipment Damage. Failure to perform a daily
inspection could result in damage to the unit.

A

Содержание DF 2.2

Страница 1: ...ERENCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For DF 2 2 Dust Suppression System For technical assistance contact www generacmobileproducts com Te...

Страница 2: ...nance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to verify that all maint...

Страница 3: ...3 Section 2 General Information Specifications 5 Component Locations 5 Setup 6 Water System Connection 6 Electrical Connection 6 Section 3 Operation Operation and Use Questions 7 Before Starting 7 St...

Страница 4: ...2 Owner s Manual for MDG25IF4...

Страница 5: ...dealer go to https www gener acmobileproducts com parts service find service When contacting an ASD about parts and service always supply the complete model and serial number of the unit as given on t...

Страница 6: ...82a WARNING Equipment damage Only qualified service personnel may install operate and maintain this equipment Failure to follow proper installation requirements could result in death serious injury an...

Страница 7: ...a Failure to do so could result in death or serious injury DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or serious injury 000263a CA...

Страница 8: ...4 Owner s Manual for DF 2 2 Dust Suppression System Introduction and Safety This page intentionally left blank...

Страница 9: ...l min 14 5 1 44 1 0 5 4 21 8 1 74 1 5 6 6 29 1 98 2 0 7 5 36 3 2 25 2 5 8 5 Air Flow ft3 min mm3 min 295 90 Water Inlet Filter m 300 Nozzles Holder Stainless steel w 12 connection Tilting Angle 10 to...

Страница 10: ...Personal injury Only use water from controlled reliable sources Uncontrolled water could contain bacteria Inhaling mist containing bacteria could result in death or serious injury A B 008852 Table 1...

Страница 11: ...onductive implements to free victim from live conductor Apply first aid and get medical help Failure to do so will result in death or serious injury 000152 DANGER Electrocution Verify electrical syste...

Страница 12: ...nd the work site when moving or lifting the unit When lifting the unit attach any slings chains or hooks directly to the central lift point A Use forklift pockets B with care Avoid approaching the uni...

Страница 13: ...cing the unit always follow the instructions listed below 1 Verify unit power switch is OFF 2 Disconnect shore power from the unit 3 Disconnect water supply from the unit 4 Attach a DO NOT USE sign to...

Страница 14: ...antilimestone solution over night 3 Rinse nozzles 4 Reinstall nozzles Figure 4 3 Cleaning Nozzles General Troubleshooting This information is intended to be a check or verification for simple causes...

Страница 15: ......

Страница 16: ...hts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Mobile Products LLC 215 Power...

Отзывы: