Generac Power Systems CW15 Скачать руководство пользователя страница 19

Water Pump

15

5.1 — O

PERATION

If you have any problems operating your water pump, 
please call Generac customer service at 
1-888-436-3722.

5.2 — 

WATER

 

PUMP

 L

OCATION

 5.2.1 — Clearances and Air Movement

Running engine gives off carbon monoxide, 
an odorless, colorless, poisonous gas. 
Breathing carbon monoxide can cause head-
ache, fatigue, dizziness, vomiting, confusion, 
seizures, nausea, fainting or death. For more 
information, reference the CO warnings in the 
“Safety”
 section.

Place water pump outdoors in an area that will not accu-
mulate deadly exhaust gas. NEVER place water pump 
where exhaust gas could accumulate and enter inside or 
be drawn into a potentially occupied building. Ensure 
exhaust gas is kept away from any windows, doors, ven-
tilation intakes, or other openings that can allow exhaust 
gas to collect in a confined area. Prevailing winds and air 
currents should be taken into consideration when posi-
tioning water pump (Figure 5-1).

• Operate water pump ONLY outdoors.

• Keep exhaust gas from entering a confined area 

through windows, doors, ventilation intakes, or other 
openings.

• NEVER start or run engine indoors, in a vehicle or in 

an enclosed area, EVEN if windows and doors are 
open.

Exhaust heat/gases can ignite combus-
tibles, structures or damage fuel tank 
causing a fire.

• Keep at least 5 ft. (152 cm) clearance on all sides of 

water pump including overhead.

Figure 5-1. Building Clearances

Place the pump on a level surface free from any obstruc-
tions or potential hazards. The pump should be placed 
close to the water level to ensure maximum performance. 

Pump output will be affected by the type, length, and size 
of the suction and discharge hoses. The pumping height, 
total head, is the distance from the water level to the 
point of discharge (Figure 5-2). As this distance 
increases, the pump output decreases. The discharge 
capacity is greater than the suction capacity, therefore it 
is important to keep the suction head less than the dis-
charge head. The time required to draw water from the 
source to the pump (self-priming time) can be decreased 
by minimizing the suction head.

Figure 5-2. Pump Output

5 Foot Minimum

Section 5 

Operation

Содержание CW15

Страница 1: ...www generac com or 1 888 436 3722 Owner s Manual Water Pump Model ST20 Model Number Serial Number Model CW15...

Страница 2: ...stituents are known to the state of California to cause cancer birth defects and other reproductive harm WARNING California Proposition 65 This product contains or emits chemicals known to the state o...

Страница 3: ...on 15 5 2 Water Pump Location 15 5 3 Checklist Before Starting Engine 16 5 4 How to Start Your Water Pump 16 5 5 How to Stop Your Water Pump 17 Section 6 Maintenance 6 1 Maintenance Recommendations 19...

Страница 4: ...iv...

Страница 5: ...fore use Refer to the Assembly section of the manual for instructions on final assembly procedures Follow the instructions completely The manufacturer cannot anticipate every possible cir cumstance th...

Страница 6: ...2 Water Pump This page intentionally left blank Introduction...

Страница 7: ...n which if not avoided could result in minor or moderate injury NOTE Notes contain additional information import ant to a procedure and will be found within the regu lar text body of this manual These...

Страница 8: ...s burns Exhaust heat gases can ignite combustibles structures or damage fuel tank causing a fire DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at leas...

Страница 9: ...is filled with water before start ing the engine NEVER run pump without priming Use a non collapsible hose on the suction side of the pump Use the pump only for its intended uses 2 1 5 Hearing Protect...

Страница 10: ...missing parts or without protective housing or covers DO NOT by pass any safety device on this machine DO NOT operate water pump above rated head DO NOT modify water pump in any way Before starting w...

Страница 11: ...Choke Prepares a cold engine for starting J Air Filter Protects engine by filtering dust and debris out of the intake air K Recoil Starter Used for starting the engine L Engine ON OFF Switch Turn swi...

Страница 12: ...General Information 8 Water Pump Figure 3 2 CW15 Features and Controls Figure 3 3 Features and Controls H I J M K L B C D A G E F Q V U T S R W X Y...

Страница 13: ...ng backfiring Black exhaust smoke or high fuel consumption 3 4 HIGH ALTITUDE OPERATION The fuel system on this engine may be influenced by operation at higher altitudes 3 5 UNPACKING 1 Remove the loos...

Страница 14: ...10 Water Pump This page intentionally left blank General Information...

Страница 15: ...n Mounts feet Figure 4 1 A Attach the vibration mount to the frame using 2 Flange Bolts M8x40 and 2 Nuts M8 B Slide the bolts through the vibration mount and through the frame C Secure with nuts Tight...

Страница 16: ...ne to run on alternate fuels To protect the fuel system from gelling mix in a fuel stabi lizer when adding fuel See Storage All fuel is not the same If you experience starting or performance prob lems...

Страница 17: ...ing with a hose clamp 3 Attach the green suction hose to the green colored flange by sliding the hose over the barb and securing with a hose clamp Figure 4 7 Figure 4 7 Attach Hoses 4 Attach the filte...

Страница 18: ...14 Water Pump This page intentionally left blank Set up...

Страница 19: ...Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings NEVER start or run engine indoors in a vehicle or in an enclosed area EVEN if windows and do...

Страница 20: ...this instruction will void warranty 5 4 1 Starting the CW15 Water Pump 1 Flip engine switch A to the ON position Figure 5 3 2 Move choke lever B to CHOKE position A For a warm engine be sure the choke...

Страница 21: ...on all sides of water pump including overhead It is a violation of California Public Resource Code Section 4442 to use or operate the engine on any for est covered brush covered or grass covered land...

Страница 22: ...18 Water Pump This page intentionally left blank Operation...

Страница 23: ...ar A new spark plug and clean air fil ter assure proper fuel air mixture and help your engine run better and last longer 6 2 MAINTENANCE SCHEDULE Follow the hourly or calendar intervals whichever occu...

Страница 24: ...KING REPAIRS TO YOUR WATER PUMP Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO...

Страница 25: ...re water pump is on a flat level surface 2 Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug A Figure 6 3 and...

Страница 26: ...ag to wipe off the hose 3 Empty pump of all liquids Remove drain cap let drain completely replace drain cap 4 Store unit in a clean dry area 5 If storing for more than 30 days see the Long Term Storag...

Страница 27: ...nkcase Refill with recommended grade See Chang ing Engine Oil Hot oil may cause burns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thor oughly wash...

Страница 28: ...24 Water Pump This page intentionally left blank Maintenance...

Страница 29: ...well as it should 1 Flow is restricted due to debris build up 2 Insufficient submergence of the end of suction hose 3 Excessively worn impeller 2 4 Seal is damaged 3 Liquid will be leaking through th...

Страница 30: ...32 Water Pump This page intentionally left blank Troubleshooting...

Страница 31: ......

Страница 32: ...ts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290 Hw...

Отзывы: