Generac Portable Products 7500 EXL Generator
13
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . . . . .9,375 watts
Continuous Wattage Capacity . . . . . . . . . . . . .7,500 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous Load Current
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .62.5 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .31.2 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity. . . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
GENERAL MAINTENANCE
RECOMMENDATIONS
The owner/operator is responsible for making sure that all
periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine Maintenance
See engine owner’s manual for instructions.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. Water
and dirt buildup on the generator internal windings will
eventually decrease the insulation resistance of these
windings.
To Clean the Generator
• Use a damp cloth to wipe exterior surfaces clean.
• Soft, bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
STORAGE
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot be
done and you must store the unit for more than 30 days, use
the following guidelines to prepare it for storage.
Generator Storage
• Clean the generator as outlined in “To Clean the
Generator.”
• Check that cooling air slots and openings on generator are
open and unobstructed.
• Disconnect negative battery cable from battery. Protect
battery from freezing temperatures.
DANGER!
Storage covers can be flammable. Do
Not place a storage cover over a hot generator. Let
the unit cool for a sufficient time before placing a cover
on the unit.
Engine Storage
See engine owner’s manual for instructions.
Other Storage Tips
• Do Not store gasoline from one season to another.
• Replace your gasoline can if it starts to rust. Rust and/or
dirt in a gasoline can cause problems if you use
contaminated fuel.
• Store unit in a clean and dry area.
Содержание 7500EXL Rated watt Extended Life Generator
Страница 15: ...Generac Portable Products 7 500 EXL Generator 15 NOTES ...
Страница 16: ...Generac Portable Products 7 500 EXL Generator 16 ELECTRICAL SCHEMATIC ...
Страница 17: ...Generac Portable Products 7 500 EXL Generator 17 WIRING DIAGRAM ...
Страница 18: ...Generac Portable Products 7 500 EXL Generator 18 EXPLODED VIEW MAIN UNIT ...
Страница 22: ...Generac Portable Products 7 500 EXL Generator 22 NOTES ...
Страница 23: ...Generac Portable Products 7 500 EXL Generator 23 NOTES ...