Generac Power Systems 7 kW PowerPact Скачать руководство пользователя страница 6

2

Automatic Standby Generator Owner’s Manual

1.1 — General Safety

Study these safety rules carefully before operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The 
generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing 
to follow simple and fundamental rules or precautions.
The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and 
decals affixed to the unit are, therefore, not all-inclusive. If using a procedure, work method or operating technique the manufacturer does not 
specifically recommend, ensure that it is safe for personnel. Also make sure the procedure, work method or operating technique utilized does not 
render the generator unsafe.

Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or 
being careless can cause possible injury or death. Permit only responsible and capable persons to install, operate 
and maintain this equipment.
Potentially lethal voltages are generated by these machines. Ensure steps are taken to make the machine safe 
before attempting to work on the generator.
Parts of the generator are rotating and/or hot during operation. Exercise care near a running generator.

The installation of this generator must always comply with applicable codes, standards, laws and regulations.

A running generator gives off DEADLY carbon monoxide, an odorless, colorless, poisonous gas. Breathing carbon 
monoxide can cause dizziness, throbbing temples, nausea, muscular twitching, headache, vomiting, weakness, 
sleepiness, inability to think clearly, fainting, unconsciousness or even death.

The control panel for this unit is intended to be operated by qualified service personnel only.

1.2 — General Safety Hazards

• For safety reasons, this equipment should only

 

be installed, serviced and repaired by a Service Dealer or other competent, qualified electri-

cian or installation technician who is familiar with applicable codes, standards, regulations and product Installation Manual guidelines. The 
operator also must comply with all such codes, standards, regulations and product Installation Manual guidelines.

• The engine exhaust fumes contain carbon monoxide, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can 

cause unconsciousness or even death. DO NOT alter or add to the exhaust system or do anything that might render the system unsafe or in 
noncompliance with applicable codes and standards.

• Install a carbon monoxide alarm indoors, according to manufacturer’s instructions/recommendations.
• Adequate, unobstructed flow of cooling and ventilating air is critical for correct generator operation. Do not alter the installation or permit even 

partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. The generator MUST be installed and 
operated outdoors only.

• Keep hands, feet, clothing, etc. away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the 

unit is operating.

• When working on this equipment, remain alert at all times. Never work on the equipment when physically or mentally fatigued.
• Inspect the generator regularly, and contact the nearest Dealer for parts needing repair or replacement.
• Before performing any maintenance on the generator, remove the control panel fuse and disconnect the Negative (—) battery cable to pre-

vent accidental startup. When disconnecting battery cables always remove the NEGATIVE (NEG or “—”) cable first, then remove the 
POSITVE (POS, or “+”) cable. When reconnecting the cables, connect the POSITIVE cable first, and the NEGATIVE cable last.

• Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating 

conditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

*
+

*

*

*

*

Содержание 7 kW PowerPact

Страница 1: ...FIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION n DEADLY EXHAUST FUMES OUTDOOR INSTALLATION ONLY LISTED C US To locate in Spanish go to http www generac com service support product suppor...

Страница 2: ...m number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to make sure that all maintenance for safe operation is performed prompt...

Страница 3: ...Alarm Response Procedures 11 3 5 Automatic Operation 12 3 6 Turning the Generator Off When Operating Under Load 13 3 7 Manual Transfer Operation 13 3 8 Side Compartment 14 3 9 Battery Charger 15 3 10...

Страница 4: ...iv This page intentionally left blank...

Страница 5: ...t Authorized Service Dealer for starting operating and servicing procedures SAVE THESE INSTRUCTIONS The manufacturer suggests that this manual and the rules for safe operation be copied and posted nea...

Страница 6: ...ards For safety reasons this equipment should only be installed serviced and repaired by a Service Dealer or other competent qualified electri cian or installation technician who is familiar with appl...

Страница 7: ...uctor AVOID DIRECT CONTACT WITH THE VICTIM Use a nonconducting implement such as a dry rope or board to free the victim from the live conductor If the victim is unconscious apply first aid and get imm...

Страница 8: ...e to install a transfer switch The transfer switch must effectively isolate the electrical system from the utility distribution system when the generator is operating NEC 702 Failure to isolate an ele...

Страница 9: ...gainst potentially damaging conditions Some of these systems are as follows The control panel contains LEDs which alert the operator when a fault condition occurs For more information about alarms and...

Страница 10: ...r local laws To ensure that the engine complies with the applicable emission standards for the duration of the engine s life it is important to follow the maintenance specifications in the Section 4 M...

Страница 11: ...in lbs kg 280 127 3 Enclosure Galvanneal Steel Normal Operating Range This unit is tested in accordance to UL 2200 standards with an operating temperature of 20 F 29 C to 122 F 50 C For areas where te...

Страница 12: ...rator along with oil recommendations Mobile Link Provides a personalized web portal that displays the generator s status maintenance schedule event history and much more This portal is accessible via...

Страница 13: ...r s Manual 9 3 1 Controller Lid Operation Lift lid from bottom to open Lid will secure in place when opened Figure 3 1 Open Control Panel Lid Pull on lid slightly to close Figure 3 2 Close Control Pan...

Страница 14: ...ent possible injury that might be caused by such sudden starts always set to OFF and remove the fuse s disconnect the battery negative cable and shut off utility power at the MLCB before working on or...

Страница 15: ...and correct Warning and Alarm conditions contact the nearest Authorized dealer or Trained Technician Button Description of Operation AUTO GREEN Selecting this button activates fully automatic system o...

Страница 16: ...when the utility fails below 65 of nominal a 5 second line interrupt delay time is started If the utility is still gone when the timer expires the engine will crank and start Once started a 6 second...

Страница 17: ...esult in extremely hazardous and possibly fatal electrical shock Prior to automatic operation manually exercise the transfer switch to verify that there is no interference with proper operation of the...

Страница 18: ...restored transfer back to utility source and shut down the generator To manually transfer back to utility power and shut down the generator 1 Set the Main Circuit Breaker Generator Disconnect to its O...

Страница 19: ...e exercise cycle unless utility power is lost 1 Place the generator in the AUTO mode 2 Hold the SET EXERCISE Button for 3 seconds The generator will start run an exercise cycle and confirm the setting...

Страница 20: ...16 Automatic Standby Generator Owner s Manual This page intentionally left blank...

Страница 21: ...ssions critical maintenance consists of servicing the air filter and spark plugs in accordance with the Service Schedule The Control Panel will prompt for break in or regular maintenance when it is re...

Страница 22: ...X W Battery Remove corrosion ensure dryness X X Y Clean and tighten battery terminals X X Y Check charge state X X Y Electrolyte level unsealed batteries only X X Every 6 M Engine and Mounting Air cle...

Страница 23: ...the dipstick oil fill cap and add oil to the engine until the level reaches the Full mark and reinsert the dipstick oil fill cap 8 If the generator was running during a utility outage first turn the...

Страница 24: ...battery and remove the fuse 4 Remove the drain hose from the retaining clamp and direct the hose end into a suitable container See Figure 4 3 5 Unscrew the drain hose cap and allow engine oil to drai...

Страница 25: ...aner cover and engage the wire clip 7 Install the enclosure top lid Tighten fasteners securely 8 Place generator in AUTO Figure 4 4 Air Filter Location 4 5 Spark Plug Reset the spark plug gap or repla...

Страница 26: ...n a clockwise direction While watching the piston through the spark plug hole The piston should move up and down Watch the intake valve open and close The piston is at TDC of it s compression stroke w...

Страница 27: ...s Do not lay tools or metallic objects on top of the battery Disconnect the charging source remove T1 fuse from Transfer Switch prior to connecting or disconnecting battery terminals Do not open or mu...

Страница 28: ...the battery area Discharge static electricity from the body before touching the battery by first touching a grounded metal surface The battery should be regularly inspected per the Service Schedule 1...

Страница 29: ...in salt water coastal areas Spray engine linkages with a light oil such as WD 40 4 10 Out of Service Procedure 4 10 1 Removal From Service If the generator cannot be exercised every 7 days and will be...

Страница 30: ...e 7 5 Amp ATO fuse is removed from the generator Control Panel 6 Reconnect the battery Observe battery polarity Damage may occur if the battery is connected incorrectly Install positive cable first 7...

Страница 31: ...e plug s 3 Confirm fuel pressure to regulator is 10 12 water column 19 22mm mercury for LP and 3 5 7 water column 9 13mm mercury for natural gas 4 Move selector to correct position Generator is set to...

Страница 32: ...28 Automatic Standby Generator Owner s Manual This page intentionally left blank...

Страница 33: ...blem is displayed Unit will not start in AUTO with utility loss Check for alarms OVERCRANK Check fuel line shutoff valve is in the ON position Clear alarm Attempt to start the unit in MANUAL If it doe...

Страница 34: ...30 Automatic Standby Generator Owner s Manual This page intentionally left blank...

Страница 35: ......

Страница 36: ...All rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45...