Never

handle any kind of electrical cord or device

while standing in water, while barefoot, or while

hands or feet are wet. Death or serious injury from

electrocution may result.

• Use a ground fault circuit interrupter (GFCI) in any

damp or highly conductive area (such as metal

decking or steel work).

•

Never

use worn, bare, frayed or otherwise damaged

electrical cords with the generator. Death, serious

injury, or property damage from electrical shock may

result.

•

Gasoline is highly FLAMMABLE and its vapors

are EXPLOSIVE. Never allow smoking, open

flames, sparks or heat in the vicinity while

handling gasoline. Avoid spilling gasoline on a

hot engine.

Comply with all laws regulating storage

and handling of gasoline.

•

Do Not

overfill the fuel tank. Always allow room for

fuel expansion.

If tank is overfilled, fuel can

overflow onto a hot engine and cause a FIRE or

an EXPLOSION.

•

Never

store a generator with fuel in the tank where

gasoline vapors might reach an open flame, spark or

pilot light (as on a furnace, water heater, clothes

dryer). FIRE or an EXPLOSION may result.

• The unit requires an adequate flow of cooling air for

its continued proper operation. 

Never

operate the

unit inside any room or enclosure where the free

flow of cooling air into and out of the unit might be

obstructed. Allow at least 2 feet of clearance on all

sides of generator, or you could damage the unit.

Read “Cold Weather Operation” on page 8.

•

Never

start or stop the unit with electrical loads

connected to receptacles and with the connected

devices turned ON. Start the engine and let it

stabilize before connecting any electrical loads.

Disconnect all electrical loads before shutting down

the generator.

•

Do Not

insert any object through cooling slots of the

engine. You could damage the unit or injure yourself.

• Never operate the generator:

in rain; in any enclosed compartment; when

connected electrical devices overheat; if electrical

output is lost; if engine or generator sparks; if flame

or smoke is observed while unit is running; if unit

vibrates excessively.

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame

and external electrically conductive parts of this

generator be properly connected to an approved earth

ground. Local electrical codes may also require proper

grounding of the unit. For that purpose, a

GROUNDING WING NUT is provided on the

generator (Figure 1).

Generally, connecting a No. 12 AWG (American Wire

Gauge) stranded copper wire to the grounding wing

nut and to an earth–driven copper or brass grounding

rod (electrode) provides adequate protection against

electrical shock. Be careful to keep the grounding wire

attached to the generator when connecting the

stranded copper wire to the grounding rod. However,

local codes may vary widely. Consult with a local

electrician for grounding requirements in your area.
Properly grounding the generator helps prevent

electrical shock if a ground fault condition exists in the

generator or in connected electrical devices. Proper

grounding also helps dissipate static electricity, which

often builds up in ungrounded devices.

Figure 1 - Grounding Wing Nut

Grounding Wing Nut

Содержание 5500XL

Страница 1: ...le RV Carbon monoxide poisoning fire and or an explosion may result No user performed modifications including venting of exhaust and or cooling ventilation will eliminate the danger Always have at lea...

Страница 2: ...shortened SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have an...

Страница 3: ...unit with electrical loads connected to receptacles and with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loa...

Страница 4: ...or against electrical overload Breakers are push to reset type Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit Idle Control Switch With this switch set t...

Страница 5: ...ine with unit Do Not use premium gasoline Do Not mix oil with gasoline Clean area around fuel fill cap remove cap Slowly add unleaded regular gasoline to fuel tank Be careful not to overfill Allow abo...

Страница 6: ...4 Grasp starter grip and pull slowly until you feel slight resistance then pull quickly Do Not let handle snap back into engine When engine starts move choke lever to Run position by sliding it all th...

Страница 7: ...protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns If spill occurs flu...

Страница 8: ...nerator Make sure entire muffler side of generator is exposed as shown in Figure 6 Note that your generator may appear different from that shown here Ensure a minimum of two feet clearance between ope...

Страница 9: ...to reset circuit breaker 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater You can use t...

Страница 10: ...g wattage when selecting electrical devices to connect to your generator First figure the watts needed to start the largest motor Add to that figure the running watts of all other connected loads Item...

Страница 11: ...soft bristle brush may be used to loosen caked on dirt or oil A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect...

Страница 12: ...ark plug 7 Water in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to RUN 2 Clean or replace a...

Страница 13: ...Circuit Breaker 12 23365 6 8 Shakeproof Washer 13 68868 1 120 Volt AC 30 Amp Locking Outlet Item Part Qty Description 14 43437 1 120V 240V AC 30A Locking Outlet 15 63025 1 120V AC 15A Duplex Outlet 1...

Страница 14: ...Generac Portable Products 5500XL Extended Life Generator 14 ELECTRICAL SCHEMATIC...

Страница 15: ...Generac Portable Products 5500XL Extended Life Generator 15 WIRING DIAGRAM...

Страница 16: ...Generac Portable Products 5500XL Extended Life Generator 16 EXPLODED VIEW UNIT...

Страница 17: ...WASHER 10 Shakeproof Int 36 86494 1 SCREW M6 1 0 x 16 Wing 37 86292 7 HHCS 10 Self Driller 38 77395 4 NUT M6 Flange Lock 39 83465 4 GROMMET Tank 40 57058 4 HHCS M6 1 0 x 55 Item Part Qty Description 4...

Страница 18: ...h have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement...

Отзывы: