5,000 Watt  Portable Generator

9

SPECIFICATIONS

Maximum Surge Watts  . . . . . . . . . . . . . . . . .6,250 watts
Continuous Wattage Capacity  . . . . . . . . . . .5,000 watts
Power Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:

At 120 Volts  . . . . . . . . . . . . . . . . . . . . . . .41.7 Amps
At 240 Volts  . . . . . . . . . . . . . . . . . . . . . . .20.8 Amps

Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency  . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 5 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 158 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.

Engine Maintenance

See engine owner’s manual for instructions.

CAUTION!

Avoid prolonged or repeated skin

contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of 

the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.

To Clean the Generator

• Use a damp cloth to wipe exterior surfaces clean.

• A soft bristle brush may be used to loosen caked on dirt

or oil.

• A vacuum cleaner may be used to pick up loose dirt and

debris.

• Low pressure air (not to exceed 25 psi) may be used to

blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.

STORAGE

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.

Generator Storage

• Clean the generator as outlined in “To Clean the

Generator.”

• Check that cooling air slots and openings on generator

are open and unobstructed.

CAUTION!

Storage covers can be flammable. Do

Not place a storage cover over a hot generator. Let
the unit cool for a sufficient time before placing the
cover on the unit.

Engine Storage

See engine owner’s manual for instructions.

Other Storage Tips

• Do Not store gasoline from one season to another.

• Replace fuel container if it starts to rust. Rust and/or dirt

in fuel can cause problems if it's used with this unit.

• Store in clean and dry area.

Содержание 1658-0

Страница 1: ... www generac portables com or www briggsandstratton com Model No 1658 0 5 000 Watt AC Generator Manual No 189633GS Revision 1 08 23 2001 Safety Rules 2 3 Assembly 4 Know Your Generator 5 Operation 6 8 Product Specifications 9 Maintenance 9 Storage 9 Troubleshooting 10 Notes 11 Schematic 12 Wiring Diagram 13 Replacement Parts 14 15 Warranty Last Page Table of Contents Generator Engine oil Owner s m...

Страница 2: ...s warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have any questions about your generator s application ask your dealer or consult the fac...

Страница 3: ...n all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loads before shutting down the generator Do Not insert any object through cooling slots of the ...

Страница 4: ...s revolving field rides on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Always allow ...

Страница 5: ...ovided with a push to reset circuit breaker to protect the generator against electrical overload Fuel Tank Capacity of five 5 U S gallons Grounding Wing Nut Used for proper grounding of unit Oil Fill Cap Add oil to engine here Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch off engine KNOWYOUR GENERATOR Read this o...

Страница 6: ...l level in crankcase This unit is equipped with a low oil device which prevents the engine from being started See engine manual Refer to the engine owner s manual for complete starting instructions Connecting Electrical Loads Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads Do Not connect 24...

Страница 7: ... Amp Locking Receptacle Use a NEMA L14 20 plug with this receptacle Connect a 4 wire cord set rated for 250 Volts AC at 20 Amps or greater You can use the same 4 wire cord if you plan only to run a 120 Volt load Figure 7 This receptacle powers 120 Volt AC single phase 60Hz loads requiring up to 2 400 watts of power 2 4 kW Or it will operate 240 Volt AC single phase 60Hz loads up to 4 800 watts 4 8...

Страница 8: ...rator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or applia...

Страница 9: ...rator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp cloth to wipe ext...

Страница 10: ... 7 Water in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain gas tank and fill with fresh fuel 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank fill with fresh fuel 8 Set choke to Off position 9 Fill crankcase to pro...

Страница 11: ...5 000 Watt Portable Generator 11 NOTES ...

Страница 12: ...12 5 000 Watt Portable Generator SCHEMATIC ...

Страница 13: ...5 000 Watt Portable Generator 13 WIRING DIAGRAM ...

Страница 14: ...14 5 000 Watt Portable Generator EXPLODED VIEW MAIN UNIT ...

Страница 15: ...er 35 B2153GS 4 SCREW Self Drill 12 14 x 7 8 36 J189055GS 1 HEAT SHIELD Muffler 37 80270GS 1 VALVE Fuel Item Part Qty Description 38 56893GS 1 CRIMPTITE 10 24 x 1 2 39 55934GGS 1 CLAMP Vinyl Coated 40 B4986GS 1 DECAL Ground 41 189637GS 1 DECAL Panel 42 20566GS 1 DECAL 1 800 43 77395GS 4 NUT M6 Flange Lock 44 73054GS 1 DECAL Fuel Shut Off 45 77816GS 1 DECAL Caution Hot Muffler 46 189235GS 1 DECAL S...

Страница 16: ...nd prepaid by the purchaser This warranty does not cover normal maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement to adversely affect its performance and reliabili...

Отзывы: