background image

56 Generac

®

Power Systems, Inc.

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board (CARB) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission
Control System Warranty on your new engine.

*

In California, new utility, and lawn and garden equipment engines must be

designed, built and equipped to meet the state’s stringent anti-smog standards. Generac will warrant the emission control
system on your engine for the periods of time listed below provided there has been no abuse, neglect, unapproved modifi-
cation or improper maintenance of your engine. 

Your emission control system may include parts such as the carburetor, ignition system and exhaust system. Generac will
repair your engine at no cost to you for diagnosis, replacement parts and labor, should a warrantable condition occur.

MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:

Emissions control systems on 1995 and later model year engines are warranted for two years as hereinafter noted. If, dur-
ing such warranty period, any emission-related component or system on your engine is found to be defective in materials or
workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service Facility.

PURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES:

As the engine purchaser/owner, you are responsible for the completion of all required maintenance as listed in your factory
supplied 

Owner’s Manual.

For warranty purposes, Generac recommends that you retain all receipts covering maintenance

on your engine. However, Generac cannot deny warranty solely due to the lack of receipts or for your failure to ensure the
completion of all scheduled maintenance.

As the engine purchaser/owner, you should, however, be aware that Generac may deny any and/or all warranty coverage or
responsibility if your engine, or a part/component thereof, has failed due to abuse, neglect , improper maintenance or unap-
proved modifications, or the use of counterfeit and/or “grey market” parts not made, supplied or approved by Generac.

You are responsible for contacting a Generac Authorized Warranty Service Facility as soon as a problem occurs.

The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.

Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Facility.
To locate the Generac Authorized Warranty Service Facility nearest you, call our toll-free number:

1-800-333-1322

IMPORTANT NOTE:

This warranty statement explains your rights and obligations under the Emission Control System

Warranty (ECS Warranty), which is provided to you by Generac pursuant to California law. See also the “Generac Limited
Warranties for Generac Power Systems, Inc.,” which is enclosed herewith on a separate sheet, also provided to you by
Generac. The ECS Warranty applies 

only

to the emission control system of your new engine. If there is any conflict in terms

between the ECS Warranty and the Generac Warranty, the ECS Warranty shall apply except in circumstances where the
Generac Warranty may provide a longer warranty period. Both the ECS Warranty and the Generac Warranty describe impor-
tant rights and obligations with respect to your new engine.

Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty serv-
ice, evidence must be presented showing the date of the sale to the original purchaser/owner.

If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at
one of the following addresses:

For Air-cooled Product ...

For Liquid-cooled Product ...

ATTENTION WARRANTY DEPARTMENT

ATTENTION WARRANTY DEPARTMENT

GENERAC POWER SYSTEMS, INC.

GENERAC POWER SYSTEMS, INC.

P.O. BOX 297

211 MURPHY DRIVE

WHITEWATER, WI 53190

EAGLE, WI 53119

Part 1

Section 10 – Warranty

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

NOTE: This Emission Control Warranty Statement pertains to this product only IF the generator size is 15 kW or below.

Содержание 04389-0

Страница 1: ...Air cooled Prepackaged Automatic Standby Generators Models 04389 0 6 kW NG 7 kW LP 04456 0 10 kW NG 12 kW LP 04390 0 13 kW NG 15 kW LP DEADLY EXHAUST FUMES OUTDOOR INSTALLATION ONLY DANGER Not intend...

Страница 2: ...potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment We strongly recommend that the operator read this O...

Страница 3: ...ional Corrosion Protection 13 2 8 Voltage Regulator Adjustment 13 Section 3 Operation 13 3 1 Break in Procedure 13 3 2 Using the Auto Off Manual Switch 13 3 2 1 Auto Position 13 3 2 2 Off Position 13...

Страница 4: ...alled properly in strict compli ance with applicable codes and standards Following installation you must do nothing that might render the system unsafe or in noncompli ance with such codes and standar...

Страница 5: ...facturer s instructions and recommendations Following proper installa tion do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes standards...

Страница 6: ...of delivery but is discovered later 1 2 PROTECTION SYSTEMS Unlike an automobile engine the generator may have to run for long periods of time with no operator present to monitor engine conditions For...

Страница 7: ...GENERATOR Control Panel Battery Compartment Fuel Regulator Air Filter Exhaust Enclosure Oil Filter Data Decal Control Panel Air Filter Exhaust Enclosure Battery Compartment Fuel Regulator Oil Filter O...

Страница 8: ...current are subject to and limited by such factors as fuel Btu content ambient temperature altitude engine power and condition etc Maximum power decreases about 3 5 percent for each 1 000 feet above...

Страница 9: ...to LP follow these steps 1 Turn the main gas supply off 2 Remove the carburetor fuel hose s from the outlet port s of the demand regulator Figure 1 4 3 Disconnect wire 0 and wire 14 from the gas solen...

Страница 10: ...SWITCH 1 9 2 1 7 kW 12 kW and 15 kW Units The transfer switch shipped with this generator is enclosed in a NEMA 1 enclosure This type of enclo sure is intended for indoor use only Follow these rules I...

Страница 11: ...id that is harmful to the skin and eyes It is electrically conductive and corrosive The following procedures are to be observed Wear full eye protection and protective clothing Where electrolyte conta...

Страница 12: ...meter across transfer switch terminal lugs E1 and E2 Voltage should be 242 252 volts frequency should read about 61 63 Hertz 9 Connect the AC voltmeter test leads across termi nal lug E1 and neutral...

Страница 13: ...ansfer switch The following should occur After about six seconds the switch should transfer loads back to the utility power source About one minute after retransfer the engine should shut down 2 6 ADJ...

Страница 14: ...at no load 4 Connect an AC frequency meter across the gener ators AC output leads 5 Turn the speed adjust nut to obtain a frequency reading of 62 Hz 6 When frequency is correct at no load check the A...

Страница 15: ...witch will transfer to standby 4 Using the transfer switch s built in emergency load center turn on circuits to load the generator to approximately 25 load and run the unit for one hour 5 Run the unit...

Страница 16: ...nal lugs E1 E2 Upon restoration of utility source voltage above a pre set level generator circuit board action signals the transfer switch to transfer loads back to that power supply After retransfer...

Страница 17: ...voltage supplies may result in extremely hazardous and possibly fatal electrical shock 5 Use the manual transfer handle inside the trans fer switch to move the main contacts back to their Utility posi...

Страница 18: ...e by shutting it down if it happens to run faster than the preset limit This protection also prevents the gener ator from supplying an output that could potentially damage appliances connected to the...

Страница 19: ...ediately after the engine shuts OFF pull the oil drain hose Figure 4 4 free of its retaining clip Remove the cap from the hose and drain the oil into a suitable container Figure 4 4 Oil Drain Hose and...

Страница 20: ...rk plug s and check the condi tion Replace the spark plug s if worn or if reuse is questionable See Section 4 11 Page 20 for recommended inspection 3 Check the spark plug gap using a wire feeler gauge...

Страница 21: ...d start as soon as the battery cables are connected Be sure the utility power supply is turned off or sparking may occur at the battery posts as you attach the cables and cause an explosion 4 8 ADJUST...

Страница 22: ...igure 4 9 for vent locations Figure 4 9 Cooling Vent Locations The exhaust from this product gets extremely hot and remains hot after shutdown High grass weeds brush leaves etc must remain clear of th...

Страница 23: ...ator 4 12 2 RETURN TO SERVICE To return the unit to service after storage proceed as follows 1 Verify that utility power is turned off and that the Auto Off Manual switch is set to OFF 2 Check the tag...

Страница 24: ...s Needed H Hours FUEL Fuel lines and connections X M LUBRICATION Oil level X M Oil X AFTER BREAK IN EVERY 100 H AND Y Oil filter X AFTER BREAK IN EVERY 200 H AND Y COOLING Enclosure louvers X X W BATT...

Страница 25: ...5 Reset valve lash The engine starts hard 1 Air cleaner 1 Check replace air cleaner and runs rough plugged or damaged 2 Defective spark plug s 2 Clean re gap or replace plug s The Auto Off Manual swit...

Страница 26: ...24 Generac Power Systems Inc Section 6 Electrical Data Guardian Air cooled 7 kW 12 kW and 15 kW Generators Wiring Diagram 12 15 kW Drawing No 0C7830 B...

Страница 27: ...Generac Power Systems Inc 25 Section 6 Electrical Data Guardian Air cooled 7 kW 12 kW and 15 kW Generators Wiring Diagram 12 15 kW Drawing No 0C7830 B...

Страница 28: ...26 Generac Power Systems Inc Section 6 Electrical Data Guardian Air cooled 7 kW 12 kW and 15 kW Generators Electrical Schematic 12 15 kW Drawing No 0C7836 B...

Страница 29: ...Generac Power Systems Inc 27 Section 6 Electrical Data Guardian Air cooled 7 kW 12 kW and 15 kW Generators Electrical Schematic 12 15 kW Drawing No 0C7836 B...

Страница 30: ...HOUR METER D DIODE DSW PCB MOUNTED DIP SWITCH IC INLINE CONNECTOR ICT INTERCONNECTION TERMINALS DIAGRAM KEY CUSTOMER SUPPLIED BATTERY 12V BLACK LOP RED 86 IC 56 IC SP IM D 18 14 C1 13 0 FS 14 SS 13 5...

Страница 31: ...14 0 15A 13A 13 351 N1 N2 15B 229 351 224 225 13 0 194 N1 N2 RAR B A 178 0 CB1 351 183 11 CUSTOMER CONNECTION N2 ICT 33 N1 211 178 194 23 22 44 183 210 23 0 210 178 55 22 33 4 224 225 13A 66A 0 4 162...

Страница 32: ...FUSE 5 AMP BA BRUSH ASSEMBLY CB2 CIRCUIT BREAKER ALT EXCITATION D DIODE 15 DPE WINDING 2 23 224 77 FIELD 11 4 22 6 162 REGULATOR ELECTRONIC VOLTAGE 0 0 4 22 0 11 0 13A 66 0 85 HTO 0 6 4 WINDING 13A 77...

Страница 33: ...OWER WINDING 120V 120V 33 NEUTRAL N2 N1 23 CUSTOMER CONNECTIONS 211 178 183 194 210 0 17 0 SC FS HM 56 14 BATTERY CUSTOMER SUPPLIED SM 12V SC N2 N1 13 225 224 TX 239 56VA 1VA C2 6 C2 5 CB1 STATOR 14 1...

Страница 34: ...9 8 27 35 22 51 49 50 51 49 49 11 50 16 17 51 5 47 19 12 6 31 44 47 30 29 28 87 86 41 40 55 57 56 58 52 49 20 52 72 60 44 62 48 61 64 65 66 59 67 63 45 71 69 68 71 68 69 38 58 89 73 75 46 74 76 82 78...

Страница 35: ...38 1 HINGE LIFT OFF TYPE B PIN 42 0D3037A 1 LATCH QUARTER TURN NON LOCKING 43 0A2115 4 WASHER NYLON 250 ITEM PART NO QTY DESCRIPTION 44 022097 9 WASHER LOCK M6 1 4 45 022473 4 WASHER FLAT ZINC 46 0362...

Страница 36: ...3 19 14 15 35 11 25 17 31 14 15 5 34 16 23 36 39 38 16 31 23 2 28 29 21 17 16 4 6 7 31 23 27 42 12 45 44 20 40 33 1 43 15 35 14 30 29 28 3 28 29 41 Section 7 Exploded Views and Parts Lists Guardian Ai...

Страница 37: ...12KW 15KW 0D2985 1 CONTROL PANEL BOTTOM 7KW ITEM PART NO QTY DESCRIPTION 21 075235 4 SCREW HHC M5 0 8 X 30 G8 8 22 0D5240 1 SWITCH SPDT ON ON N D 23 051714 8 NUT HEX M3 0 5 G8 YELLOW CHROME 24 0C1457...

Страница 38: ...9 22 22 21 16 23 24 10 31 7 9 17 18 4 6 11 5 3 2 39 40 4 36 19 25 15 26 38 33 32 34 34 35 12 37 14 8 13 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW Generators 7 k...

Страница 39: ...DBY 19 063378 4 HOLDER CABLE TIE 21 074138 2 LUG DIS QK NI S 10X45 DEG BR T 22 036932 6 SCREW PPHM 10 32 X 1 4 23 077033 6 LUG SLDLSS 1 0 14X9 16 AL CU 24 048850 1 BLOCK TERMINAL 20A 5 X 6 X 1100V 25...

Страница 40: ...1 16 23 24 10 31 7 9 17 18 4 6 11 5 3 2 39 40 4 36 19 25 15 26 38 41 33 32 34 34 35 42 37 12 14 8 13 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW Generators 12 kW...

Страница 41: ...DIS QK NI S 10X45 DEG BR T 22 036932 6 SCREW PPHM 10 32 X 1 4 23 077033 6 LUG SLDLSS 1 0 14X9 16 AL CU 24 048850 1 BLOCK TERMINAL 20A 5 X 6 X 1100V 25 028739 4 TIE WRAP 3 9 X 10 NAT L UL 26 038150 2...

Страница 42: ...33 39 3 3 40 2 3 26 10 4 34 25 11 30 20 65 2 5 19 20 39 40 47 63 92 141 8 11 12 13 66 4 5 6 67 16 17 18 68 48 49 50 51 52 53 54 55 56 58 59 61 69 7 48 49 50 51 52 53 54 55 56 58 59 70 27 28 29 71 3 3...

Страница 43: ...0D1667 1 ARM GOVERNOR 34 0C2991 2 E RING GOVERNOR ARM 35 0C2988 1 THRUST WASHER GOVERNOR ITEM PART NO QTY DESCRIPTION 36 0C2992 1 BUSHING GOVERNOR LOWER 37 0C3971C 1 ASSEMBLY DIPSTICK WITH HANDLE 38...

Страница 44: ...80 130 98 118 114 126 93 92 117 78 77 75 76 74 73 122 125 123 125 119 120 137 136 134 133 132 131 127 129 135 113 101 110 121 116 115 100 128 124 124 79 86 97 96 97 96 138 139 140 Section 7 Exploded V...

Страница 45: ...CREW HHC M8 1 25 X 12 G8 8 107 0C3033 1 WASHER M5 ITEM PART NO QTY DESCRIPTION 108 0C3034 1 NUT HEX M24 109 0C8549 1 SNORKEL AIR INTAKE 110 0C3022A 1 HOUSING BLOWER NG COOLER 111 0D1131 1 GUARD FAN 11...

Страница 46: ...14 20 38 15 30 24 26 32 10 19 16 28 27 17 10 19 32 28 31 32 17 32 31 33 28 13 39 18 10 40 29 28 34 35 34 41 42 43 44 48 49 30 45 46 34 36 47 31 50 52 Section 7 Exploded Views and Parts Lists Guardian...

Страница 47: ...TAPE ELEC UL FOAM 1 8 X 1 2 23 049451 1 WASHER FLAT 406ID X 1 62OD 24 022237 4 WASHER LOCK 3 8 25 022511 4 BOLT HHC 3 8 16 X 1 1 4 G5 26 022131 4 WASHER FLAT 3 8 ZINC 27 039287 4 SCREW HHC M8 1 25 X...

Страница 48: ...4 5 23 11 24 31 12 25 22 14 20 38 15 30 24 26 32 10 19 16 28 27 17 10 19 32 28 31 32 17 32 31 33 29 28 13 28 39 18 10 40 29 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and...

Страница 49: ...038A 1 BRACKET ENGINE MOUNTING 17 0C7758 4 RUBBER MOUNT 18 0388050AD0 1 CABLE 6 48 BLACK BATTERY 19 0C2417A 1 EARTH STRAP 3 8X 3 8 20 082121C 1 CLIP J VYNL COAT 0 625 ID 21 066386 1 ASSEMBLY BRUSH HOL...

Страница 50: ...18 19 20 23 32 44 48 24 46 11 22 29 28 31 30 17 52 1 14 13 26 38 25 25 40 41 12 21 15 16 6 1 2 4 42 10 5 7 3 8 9 49 51 50 54 53 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW...

Страница 51: ...C7393 1 BALANCER 27 021714 1 ASSEMBLY CYLINDER HEAD SEATS GUIDES ITEM PART NO QTY DESCRIPTION 28 086516 1 VALVE EXHAUST 29 086517 1 VALVE INTAKE 30 088396B 2 PUSH ROD 31 083897 2 TAPPET 32 077158 1 AS...

Страница 52: ...3 40 41 42 43 44 2 4 1 6 6 6 5 13 7 9 8 10 11 14 15 16 17 19 12 6 38 37 36 27 28 18 26 33 18 35 34 35 18 30 31 32 39 6 Section 7 Exploded Views and Parts Lists Guardian Air cooled 7 kW 12 kW and 15 kW...

Страница 53: ...22 049821 2 SCREW SHC M8 1 25 X 30 G12 9 ITEM PART NO QTY DESCRIPTION 23 099236 1 SWITCH OIL 8 0 PSI 24 070185 1 FILTER OIL DIA 69 X 64 LG 25 082774 1 KEY WOODRFF 4 X 19D 26 091222ESRV 1 FLYWHEEL WIT...

Страница 54: ...5 7KW ITEM PART NO QTY DESCRIPTION 19 0C6069 2 GASKET DIAPHRAGM 20 0C5762 2 COVER TWIN REGULATOR 21 045764 16 SCREW TAPTITE M4X8 BP 12KW 15KW 045764 8 SCREW TAPTITE M4X8 BP 7KW 22 0C6731 2 RIVET POP 1...

Страница 55: ...Generac Power Systems Inc 53 Section 8 Notes Guardian Air cooled 7 kW 12 kW and 15 kW Generators...

Страница 56: ...54 Generac Power Systems Inc Section 8 Notes Guardian Air cooled 7 kW 12 kW and 15 kW Generators...

Страница 57: ...M F CBHOM F 120 240v 120 240v TYPE HOM TYPE HOM CBHOM F CBHOM F 120 240v 120 240v TYPE HOM TYPE HOM CBHOM F CBHOM F 120 240v 120 240v TYPE HOM TYPE HOM CBHOM F CBHOM F 120 240v 120 240v M6PEM T M6PEM...

Страница 58: ...eglect improper maintenance or unap proved modifications or the use of counterfeit and or grey market parts not made supplied or approved by Generac You are responsible for contacting a Generac Author...

Страница 59: ...ction 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point...

Страница 60: ...devices the Generac engines need periodic part s service and replacement to perform well This warranty will not cover repair when normal use has exhausted the life of a part s or engine Failures caus...

Отзывы: