background image

Manual Part No. 0H0189 

Rev C (12/02/08) 

Printed in China

Section 6 — Warranty

Portable Generator System

GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR

GP SERIES PORTABLE GENERATORS

For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and 
workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or 
a Generac Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be returned to and examined 
by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the 
purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. Save your proof-of-purchase receipt. If 
you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the warranty period.

WARRANTY SCHEDULE

Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first. 

CONSUMER APPLICATION

YEARS ONE and TWO - 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
• Engine- All Components
• Alternator- All Components

COMMERCIAL/RENTAL APPLICATION

YEAR ONE – 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
• Engine- All Components
• Alternator- All Components

NOTE:

  For the purpose of this warranty “consumer use” means personal residential household or recreational use by original purchaser. This warranty does not apply to units used for 

Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced commercial or 
rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.

All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedures and Flat Rate Manual.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

Generac built portable generators built prior to May 2008.

• 

Generac portable generators that utilize non-Generac replacement parts.

• 

Costs of normal maintenance and adjustments.

• 

Failures caused by any contaminated fuels, oils or lack of proper oil levels.

• 

Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by Generac Power Systems.

• 

 Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper use. As with all mechanical devices, the Generac engines need periodic part(s) 

• 

service and replacement to perform as designed. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine.
 Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earth-quake, windstorm, hail, volcanic 

• 

eruption, water or flood, tornado or hurricane.
Damage related to rodent and/or insect infestation.

• 

Products that are modified or altered in a manner not authorized by Generac in writing.

• 

Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).

• 

Failure due to misapplication.

• 

Telephone, cellular phone, facsimile, internet access or other communication expenses.

• 

Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period.

• 

Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.

• 

Rental equipment used while warranty repairs are being performed.

• 

Overnight freight or special shipping costs for replacement part(s).

• 

Overtime, holiday or emergency labor.

• 

Starting batteries, fuses, light bulbs and engine fluids.

• 

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not 
apply to you. GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY 
INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or 
limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to 
state.

GENERAC POWER SYSTEMS, INC.

P.O. BOX 8 • Waukesha, WI 53187

Ph: (888) GENERAC (436-3722) • Fax: (262) 544-4851

To locate the nearest Authorized Dealer visit our website www.generac.com 

Part No. 0G9451 

Revision D  (10/27/08) 

Printed in U.S.A.

Содержание 005724-0

Страница 1: ...Owner s Manual SAFETY ASSEMBLY OPERATION TROUBLESHOOTING WARRANTY MODEL 005724 0 www generac com or 1 888 GENERAC AUTHORIZED DEALER SUPPORT GP Series Portable Generator ...

Страница 2: ...nque del motor 24 2 8 Detención del motor 24 2 9 Sistema de apagado por bajo nivel de aceite 24 Sección 3 Mantenimiento 25 3 1 Programa de mantenimiento 25 3 2 Especificaciones del producto 25 3 3 Recomendaciones generales 25 3 4 Mantenimiento del filtro de aire 26 3 5 Holgura de la válvula 27 3 6 General 27 3 7 Almacenamiento a largo plazo 27 3 8 Otras sugerencias para el almacenamiento 27 Secció...

Страница 3: ...indoors WILL KILL YOU IN MINUTES Exhaust contains carbon monoxide a poison gas you cannot see or smell NEVER use in the home or in partly enclosed areas such as garages ONLY use outdoors and far from open windows doors vents and in an area that will not accumulate deadly exhaust gas Using a generator indoors WILL KILL YOU IN MINUTES Exhaust contains carbon monoxide a poison gas you cannot see or s...

Страница 4: ...rators Do not touch hot surfaces such as the muffler Severe burns can occur on contact Allow generator to cool before touching GENERAL HAZARDS Never operate in an enclosed area or indoors For safety reasons the manufacturer recommends that the maintenance of this equipment is carried out by an Authorized Dealer The engine exhaust fumes contain carbon monoxide which can be DEADLY This dangerous gas...

Страница 5: ...s the Occupational Safety and Health Administration OSHA has established Also ensure that the generator is operated in accordance with the manufacturer s instructions and recommendations Do not alter the construction of the generator or change controls which might create an unsafe operating condition Keepafireextinguishernearthegeneratoratalltimes Extinguishers rated ABC by the National Fire Prote...

Страница 6: ...rough the wheel axle hole Bend the cotter pin tabs outward to lock the pin in place 2 Refer to Figure 1 to install the wheel bumpers as shown Insert an M6 bolt through the rubber bumper and the bottom of the bumper bracket Secure the bolt with an M6 flange nut Install an M6 bolt through the generator frame and through top of the bumper bracket Secure the bolt with an M6 flange nut 3 Refer to Figur...

Страница 7: ...engine manually 14 Fuel Shut Off Valve between fuel tank and carburetor 15 Oil Drain Plug Used to drain engine oil 16 Spark Arrestor Reduces fire hazard by containing sparks Figure 4 Generator Controls 11 10 5 13 14 9 4 3 Figure 5 Generator Controls 15 12 7 16 8 6 2 2 CORD SETS AND CONNECTION PLUGS 2 2 1 120 VAC 13 5 AMP DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 1...

Страница 8: ...erloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices Observe the following to prevent overloading the unit Add up the total wattage of all electrical devices to be connected at one time This total should NOT be greater than the generator s wattage capacity The rated wattage of lights can be taken from light bulbs Th...

Страница 9: ...operly serviced with the recommended oil may result in an engine failure Place generator on a level surface Clean area around oil fill and remove oil fill cap and dipstick Wipe dipstick clean Slowly fill engine with oil through the oil fill opening until it reaches the bottom of the dipstick threads Stop filling occasionally to check oil level Be careful not to over fill Install oil fill cap and f...

Страница 10: ...s smoothly and then to RUN position NOTE If engine fires but does not continue to run move choke lever to the START position and repeat starting instructions Figure 9 Fuel Shut off Valve Fuel Shutoff Valve Choke Lever Recoil Handle Engine ON OFF Switch Figure 10 Choke Position IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected agai...

Страница 11: ...y the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain the generator All adjustments in the Maintenance section of this manual should be made at least once each season Follow the requirements in the Maintenance Schedule NOTE Once a year replace the spark plug and replace the air filter A new spark plug and cle...

Страница 12: ...se of used oil at a proper collection center 3 3 6 REPLACINGTHE SPARK PLUG Use spark plug F6TC NGK BPR4ES or Champioin RN14YC Replace the plug once each year This will help the engine start easier and run better 1 Stop the engine and pull the spark plug wire off of the spark plug 2 Clean the area around the spark plug and remove it from the cylinder head 3 Set the spark plug s gap to 0 70 0 80 mm ...

Страница 13: ...in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer as follows Remove all gasoline from the fuel tank DANGER Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke Start and run engine until engine stops from lack of fuel While engine is still warm drain oil from crankcase Refill with recommended gr...

Страница 14: ...spark plug 6 Water in gasoline 7 Over choking 8 Low oil level 9 Excessive rich fuel mixture 10 Intake valve stuck open or closed 11 Engine has lost compression 1 Clean or replace air filter 2 Fill fuel tank 3 Drain fuel tank and fill with fresh fuel 4 Connect wire to spark plug 5 Replace spark plug 6 Drain fuel tank fill with fresh fuel 7 Put choke knob to No Choke position 8 Fill crankcase to pro...

Страница 15: ...13 Section 5 Notes ...

Страница 16: ...ac replacement parts Costs of normal maintenance and adjustments Failures caused by any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Systems Failures due but not limited to normal wear and tear accident misuse abuse negligence or improper use As with all...

Отзывы: