Generac Power Systems 004812-0 Скачать руководство пользователя страница 80

0C3594 

ASSEMBLY M6 HINGE 

0A3359 

32 

SCREW BHSC M6-1.0 X 16 SS 

(1) 4 

022769 

WASHER SHAKEPROOF INT #10 

042907 

SCREW HHC M8-1.25 X 16 G8.8 

022129 

WASHER LOCK M8-5/16 

(5) 7 

     0C3333 

DUCT FRONT LH 

(5) 8 

     0C3334  

DUCT FRONT RH 

(5) 9 

     0C3335  

DUCT BOTTOM 

(5) 10 

     0C3336  

DUCT FRONT PANEL 

(6) 11 

   0C2403A 

DUCT FRONT TOP 

12 

       0C2454 

95 

SCREW TH-FRM M6-1 X 16 N WA Z/JS 

(5) 13 

     0C2522  

DOOR SMALL STD. WELD 

(5) 14 

     0C2529  

CORNER POST LH REAR 

(5) 15 

     0C2530  

CORNER POST RH REAR 

(5) 16 

     0C2537  

CORNER POST LH FRONT 

(5) 17 

     0C2538  

CORNER POST RH FRONT 

(5) 18 

     0C2637  

REAR PANEL SOUND 

(5) 19 

     0F1255  

BRACE SIDE TOP AND BOTTOM 

(5) 20 

     0C2556  

SIDE SUPPORT 

21 

0E3257 

SCREW TH-FRM M6 W/CAP SHKPRF W 

(6) 22 

0F1229 

ROOF WELDMENT ACOUSTIC ENCL 

(5) 23 

     0C2590  

FRONT BRACE TOP 

24 

0C2633 

STRIKER PLATE 

25 

   0C2634A 

ACCESS COVER ASSEMBLY 

27 

022097 

WASHER LOCK M6-1/4 

28 

022473 

WASHER FLAT M6-1/4 ZINC 

29 

0C6749 

16 

SCREW PPHC M4 x 12 SS 

(2) 30 

077992 

28 

NUT HEX M6-1.0 

31 

060069 

PADDLE HANDLE LOCK 

32 

0C6748 

16 

NUT LOCK HEX M4-0.7 SS NYL INS 

33 

080490 

16 

WASHER FLAT #8 SS 

34 

087233 

12 

RIVET POP .1875 X .192-.196/#11 

(5) 35 

     0C3443  

DUCT REAR LH 

(5) 36 

     0C3442  

DUCT REAR RH 

(5) 37 

     0C3444  

DUCT REAR PANEL 

38 

0A9881 

   1 

GASKET DOOR RUBBER (472”) 

(5) 39 

     0C2596  

DUCT REAR TOP 

40 

0C3157 

INSULATION FRONT DUCT 

41 

  0A5035A 

48 

HANGER SELF ADHESIVE 3/4 

43 

  0C3157B 

INSULATION DUCT BOTTOM 

44 

  0C3157C 

INSULATION DUCT FRONT PANEL 

45 

  0C3157D 

INSULATION REAR DUCT  

47 

  0C3157F 

INSULATION REAR PANEL 

48 

  0C3157G 

INSULATION REAR DUCT TOP 

49 

0F1275 

INSULATION FRONT ROOF 

50 

  0C3157J 

INSULATION FRONT ROOF TOP 

51 

  0C3157K 

INSULATION DOOR 

(3) 52 

  0C3157L 

INSULATION DOOR 

53 

  0C3157M 

INSULATION FRONT CORNER POST 

54 

  0C3157N 

INSULATION FRONT CORNER POST 

55 

  0C3157P 

INSULATION TOP & BOTTOM SIDE BRACE 

56 

  0C3157Q 

INSULATION SIDE SUPPORT 

57 

  0C3157R 

INSULATION FRONT BRACE TOP 

58 

  0C3157S 

INSULATION REAR PANEL 

59 

  0C3157T 

INSULATION REAR CORNER POSTS 

(5) 60 

     0C2643  

DUCT DOOR GEN 2000 

61 

078115 

48 

WASHER, SELF LOCKING DOME 

62 

022127 

NUT HEX 1/4-20 STEEL 

64 

0C3393 

SHOULDER SCREW 

(5) 65 

     0C3400  

COVER EXHAUST HOLE 

67 

     0F7323 (4)(5) 

DOOR SMALL ACO 

 

0C2521A (3)(6)  

DOOR,SM ACO WELD AL 

69 

 0C3157U 

INSULATION REAR CORNER POSTS 

71 

     0E1116  

RAD BLOCK-OFF RH/LH SIDE 3.9L 

72 

     0E1117  

RAD BLOCK-OFF TOP 3.9L MITSU 

73 

 0C3157V 

INSULATIONDUCT REAR DOOR 

74 

   0C3157W 

INSULATION REAR  ROOF TOP 

75 

  0C3157X 

INSULATION REAR ROOF TOP 

76 

  0C3159Y 

INSULATION FRONT DUCT RH & LH 

77 

  0C3157Z 

INSULATION REAR DUCT RH & LH 

(3) 78 

0C6747 

16 

STANDOFF M4 X 19.1 AL 

(3) 79 

0C2635 

COVER, LATCH ACOUSTIC 

(5) 80 

     0C5356 

VARMIT BLOCKOFF PLATE 

81 

066760 

SEALANT STRIP 1/8 X 1 (78 3/4”) 

(3) 82 

078437 

16 

WASHER LOCK 8-M4 SS 

83 

022145 

WASHER FLAT M8-5/16 ZINC 

(3) 84 

  0C3157K 

INSULATION DOOR 

(3) 85 

080490 

16 

WASHER FLAT #8 SS 

(3)86 

0C6749 

16 

SCREW PPHC M4 x 12 SS 

(4) 87 

0C3157AD 

INSULATION, SMALL DOOR 

 

 

 

 

 

 

 

 

(1) ONE PER PADDLE HANDLE 

 

 

 

 

(2) ALUMINUM ENCLOSURE NOTE: ALL ENCLOSURE          PANELS THAT FASTEN TO THE 
BASE FRAME MUST BE SECURED USING ITEM 12 & 21 THREAD FORMING FASTENER AND 
ITEM 30 LOCK NUT. LOCK NUT IS TO BE INSTALLED AFTER THREAD-FORMING FASTENER 
HAS PENETRATED THROUGH EXTRUSIONS IN ENCLOSURE PANELS. ALL ROOF PANELS 
ARE TO BE SECURED IN THE SAME MANNER. 

 

 

 

 

(3) USED FOR ALUMINUM ENCLOSURE ONLY 

 

 

 

 

(4)  USED FOR STEEL ENCLOSURE ONLY 

 

 

 

 

(5) NOTE: PART  NUMBER SHOWN IS FOR TAN / STEEL.  REFER TO THE SAMPLE  
GUIDE BELOW FOR AVAILABLE COLOR AND/OR ALUMINUM PART NUMBER FORMAT. 
0FXXXX0ST01 = TAN / STEEL                            0FXXXX0ST13 = BISQUE / STEEL 
0FXXXX0AL01 = TAN / ALUMINUM                    0FXXXXALT13 = BISQUE / ALUMINUM 
0FXXXX0ST05 = WHITE / STEEL                        0FXXXX0ST14 = GRAY / STEEL 
0FXXXX0AL05 = WHITE / ALUMINUM                0FXXXXALT14 = GRAY / ALUMINUM 
 
(6) PART NUMBER SHOWN IS FOR TAN. SEE GUIDE BELOW FOR AVAILABLE COLOR AND 
PART NUMBER FORMAT. 
0FXXXX0AL08 = T- GRAY / ALUMINUM              0FXXXXALT13 = BISQUE / ALUMINUM 
0FXXXX0AL05 = WHITE / ALUMINUM                 0FXXXXALT14 = GRAY / ALUMINUM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 004812-0

Страница 1: ...Owner s Manual Standby Generator Models 004812 0 004813 0 POWER SYSTEMS INC This manual should remain with the unit...

Страница 2: ...explosion hazard This symbol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment We strongly...

Страница 3: ...7 2 1 STANDBY GENERATOR INSTALLATION 7 2 1 1 NFPA Standards 8 2 1 2 Other Published Standards 8 2 2 BASIC STANDBY ELECTRIC SYSTEM 8 2 3 EMERGENCY CIRCUIT ISOLATION METHOD 8 2 4 TOTAL CIRCUIT ISOLATION...

Страница 4: ...gen erator is installed operated and serviced in accor dance with the manufacturer s instructions and recommendations Following installation you must not do anything that might render the unit unsafe...

Страница 5: ...generator is operating Failure to isolate the two electric system power sources from each other by such means will result in damage to the generator and may also result in injury or death to utility p...

Страница 6: ...EMA MG1 22 All prototype tested models have passed three phase symmetrical short circuit test to ensure system protection and reliability 1 3 ENGINE PROTECTIVE DEVICES The standby generator may be req...

Страница 7: ...ormance and reliability NOTE Appropriate care should be taken in applications where extremely low ambient temperatures are possible to ensure the temperature of the diesel fuel is not allowed to fall...

Страница 8: ...MENTS AND RECOMMENDATIONS Diesel Fuel System See Chapter 8 of Engine Generator Standby Electric Power Systems Installer s Guide and Reference Manual part 46622 1 7 GENERATOR AC LEAD CONNECTIONS The el...

Страница 9: ...ircuits and an automatic current limiter design The unit is equipped with automatic float and equalize control and uses an SCR to maintain proper charge voltage This type of sys tem precisely monitors...

Страница 10: ...CTRIC POWER available from the American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 A52 1 AMERICAN NATIONAL STANDARD FOR CHIMNEYS FIREPLACES AND VENTING SYS TEMS available fro...

Страница 11: ...ected electrical devices In addition grounding helps dissipate static electricity that often builds up in ungrounded devices Figure 2 2 Generator Grounding Lug typical 2 6 GENERATOR AC NEUTRAL CONNECT...

Страница 12: ...ed The resulting liquid is to be flushed with water and the area dried Lead acid batteries present a risk of fire because they generate hydrogen gas The fol lowing procedure are to be followed DO NOT...

Страница 13: ...hould be changed after 30 hours of operation The engine is equipped with a mechanical governor Make sure the governor is properly lubricated with clean engine oil 2 9 1 4 Engine Coolant Have the engin...

Страница 14: ...such as the utility source main line circuit break er Set the transfer handle to its Utility normal position with load circuits connected to the utility power supply Set the standby generator s main...

Страница 15: ...Retorque fan bolts Drain and refill gearbox If so equipped contact sales for availability 4 1 2 4 Every Two Years Replace all rubber hoses Replace engine fan belts Inspect the Standby Generator Syste...

Страница 16: ...o not permit fluid to contact eyes skin clothing painted surfaces etc Wear protective goggles protective clothing and gloves when handling a battery If you spill the fluid flush the affected area imme...

Страница 17: ...esponds to an identical number on the exploded view drawing 4 3 1 HOW TO ORDER PARTS To order a replacement part locate the part in the applicable exploded view Contact your Generac Authorized Service...

Страница 18: ...16 Generac Power Systems Inc Section 5 Installation Generac Standby Generator Sets Installation Diagram Models 004812 0 004813 0 Drawing No 0E3700...

Страница 19: ...Generac Power Systems Inc 17 Section 5 Installation Generac Standby Generator Sets Installation Diagram Models 004812 0 004813 0 Drawing No 0E3700...

Страница 20: ...69 14 15 150 17 18 TB1 575 567 19 20 S15 0 5 4 4 4 4 D1 AVR 2 3 162 89 1 14 219 0 2 162 89 R2 CB1 162 49 D2 2 15 220 14 219 15 220 14 219 49 CABLE 15 220 14 219 15 220 89 13 218 0 0 0 0 AVR AUTOMATIC...

Страница 21: ...WIRE COLOR BROWN RED 15 220 CABLE 15 220 14 219 89 13 218 0 0 0 0 0 56 WIRE s 4 13 29 218 0 1 R15 591 14 15 219 220 2 49 150 A1 8 R1 9 162 178 183 S1 3 590 56 56A 57 59 67 89 FUNCTION NEUTRAL FUSED DC...

Страница 22: ...E POWER GROUND RETURN GROUND RETURN PROG INPUT 8 PROG INPUT 7 PROG INPUT 5 A7 BC4 4 BC4 5 A5 A4 BC4 2 BC4 6 BC4 3 A8 567 0 0 PROG RELAY 2 PROG RELAY 1 N O COM R1 R2 N C COM R3 R4 R5 BC2 2 BC2 12 MAGNE...

Страница 23: ...MATIC VOLTAGE REGULATOR 60Hz AUTOMATIC VOLTAGE REGULATOR 50Hz ES1 3 098426C HZ L1 MC1 R1 SW1 R2 0A4087 VARIOUS 061945 044213 070202 070042A 0C8481 070042 AA AM AVR D1 D2 ES CB1 VARIOUS 049939 025192 0...

Страница 24: ...200A E1 TO E3 240V 120 240V 1 PHASE CUSTOMER CONNECTION E3 TO 00 E1 TO 00 120V LEGEND CT2 CB2 NB B S1 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED W W X T V U S N P R Q O J L M K 0 178 S2 S3...

Страница 25: ...R ARMATURE TP THERMAL PROTECTOR AUTO RESET LEGEND BRUSHLESS SERIES 4 WIRE DISPLACED PHASE WINDING VOLTAGE CODE A E1A AS 00 00 CUSTOMER CONNECTION 120 240V 1 PHASE 60HZ E1 CT1 K L l k 11 11 57 S1 22 CT...

Страница 26: ...24 Generac Power Systems Inc Section 6 Electrical Data Generac Standby Generator Sets Wiring Diagram 3 9L Models 004812 0 004813 0 Drawing No 0E2647V A...

Страница 27: ...OLENOID FUEL ENGINE HEATER GLOW PLUG SWITCH RUPTURE BASIN FLOAT GROUND 218 RED D 85 601 219 3 0 0 16 2 1 157 69 2 1 0 218 575 218 590 16 591 218 N C N O 0 GREEN BLACK WHITE 6 567 575 590 7 8 120VAC UT...

Страница 28: ...TL 18 024310 1 PLUG STD PIPE 1 2 STEEL SQ HD 19 0536210098 1 ASSEMBLY GROUNDWIRE 10 3 8 20 043107 1 SCREW HHC M8 1 25 X 25 G8 8 21 022145 1 WASHER FLAT 5 16 M8 ZINC 22 022129 1 WASHER LOCK M8 5 16 23...

Страница 29: ...M10 1 5 X 20 G8 8 6 038804T 1 CABLE BATT RED 1 X 31 00 7 046526 1 WASHER LOCK M10 8 022131 1 WASHER FLAT 3 8 M10 ZINC 9 025507 1 WASHER SHAKEPROOF EXT 7 16 STL 10 075763 1 BOOT BATTERY CABLE USED ON...

Страница 30: ...11 8 27 1 2 3 4 1 BASE FRAME 67 19 57 71 23 52 72 51 71 54 62 31 55 5 56 28 19 55 5 28 53 17 56 60 20 55 5 5 5 12 9 59 35 59 14 13 24 73 69 18 58 20 19 75 19 34 33 32 78 79 43 80 81 48 64 82 29 15 66...

Страница 31: ...SULATION DUCT FRONT PANEL ITEM PART NO QTY DESCRIPTION 45 0C3157D 2 INSULATION REAR DUCT 47 0C3157F 1 INSULATION REAR PANEL 48 0C3157G 1 INSULATION REAR DUCT TOP 49 0C3157H 1 INSULATION FRONT ROOF TOP...

Страница 32: ...30 Generac Power Systems Inc Section 7 Exploded Views and Parts Lists Generac Standby Generator Sets Tank Models 004812 0 004813 0 Drawing No 0D5400V B...

Страница 33: ...CHESTER FUEL LEVEL GAUGE 14F 0E4352 1 GASKET ADAPTER PLATE 15 0A1492 1 CAP FUEL FILL 16 0D2670 1 NECK FUEL FILL STANDARD 4 17 063831 1 PLUG STD PIPE 1 25 NPT STEEL SQ HD 18 021178 1 VENT OEM 2 NPT 19...

Страница 34: ...OF INNER WALL WITH 10 18 17 20 AC NEUT N AC HOT A G 28 G1 E4 E OUTSIDE TOP LOCATED ON 33 1 10 16 13 30 9 14 15 23 COVER GND STRAP STRAP GND H 19 23 19 2 USED AT LOCATIONS B D HEAT SHRINK TUBING TO BE...

Страница 35: ...BLOCK TERM JUMPER FOR S142 542 17 022158 4 NUT HEX 10 32 STEEL 18 022152 4 WASHER LOCK 10 19 022097 3 WASHER LOCK M6 1 4 20 036934 4 SCREW PPHM 10 32 X 5 8 21 0D3633 1 DECAL BATTCHRG 12 24V WIRING 22...

Страница 36: ...34 Generac Power Systems Inc Section 7 Exploded Views and Parts Lists Generac Standby Generator Sets Radiator Models 004812 0 004813 0 Drawing No 0E3404 D...

Страница 37: ...52250 1 TAPE FOAM 1 X 1 220 LG 31 0E4162 1 CAP RADIATOR 20 PSI 32 0E2671 2 RH LH SIDE AIR DUCT 3 9L MITSU ITEM PART NO QTY DESCRIPTION 33 0E2673 2 TOP BOTTOM AIR DUCT 3 9L MITSU 34 0A2110 4 SCREW SWAG...

Страница 38: ...CREW SHC M10 1 25 X 25 G12 9 ITEM PART NO QTY DESCRIPTION 11 022145 18 WASHER FLAT 5 16 ZINC 12 022129 12 WASHER LOCK M8 5 16 13 022237 3 WASHER LOCK 3 8 14 0C4170 2 BRACKET EXHAUST SHIELD 15 0C3094 1...

Страница 39: ...8 9 022131 10 WASHER FLAT 3 8 M10 ZINC 10 052859 4 NUT LOCK FL M10 1 50 ITEM PART NO QTY DESCRIPTION 11 046526 6 WASHER LOCK M10 12 0E2206 1 INSERT RUBBER REDUCER 3 X 2 25 13 051756 6 SCREW HHC M10 1...

Страница 40: ...38 Generac Power Systems Inc Section 7 Exploded Views and Parts Lists Generac Standby Generator Sets Circuit Breaker Models 004812 0 004813 0 Drawing No 0E3667 A...

Страница 41: ...UNT S ED 390S B 0D5620 1 COVER CB TERMINALS S ED 3P C 022097 11 WASHER LOCK M6 1 4 D 022287 8 SCREW HHC 1 4 20 X 3 4 G5 E 022471 4 NUT HEX 8 32 STEEL F 022264 4 WASHER LOCK M4 G 038150 8 WASHER FLAT 8...

Страница 42: ...40 Generac Power Systems Inc Section 7 Exploded Views and Parts Lists Generac Standby Generator Sets Engine Parts Models 004812 0 004813 0 Drawing No 0E3670 A...

Страница 43: ...7 057642 12 SCREW HHC M10 1 5 X 40 G8 8 28 022131 14 WASHER FLAT 3 8 M10 ZINC 29 043107 4 SCREW HHC M8 1 25 X 25 G8 8 30 022129 8 WASHER LOCK M8 5 16 31 022145 4 WASHER FLAT 5 16 M8 ZINC 32 046579 4 S...

Страница 44: ...OUND T 13717 NOTE 6 10 11 35 34 33 36 32 30 31 26 28 29 27 12 3 20 49 19 21 45 48 45 5 2 18 4 9 46 16 17 13 39 15 22 14 44 38 24 23 25 43 38 22 40 42 41 42 Generac Power Systems Inc Section 7 Exploded...

Страница 45: ...RING 15 23 068115 1 PANEL LOWER 15 24 043123 4 WASHER LOCK M14 25 051779 4 NUT HEX M14 2 0 G8 YEL CHR 26 052259 2 WASHER FLAT M12 27 051769 3 WASHER LOCK M12 28 068406 3 SCREW HHC M12 1 75 X 60 G10 9...

Страница 46: ...50V 082404 25 OHM 25W 75 OHM 25W P N 086266 P N 083364 50 OHM 25W P N 057405 5 OHM 25W P N 048352 0 300V 0 300V 0 600V 0 300V 0 300V 0 600V 0 300V 0 300V 0 300V METER RANGE VOLTAGE 070043 070043 07004...

Страница 47: ...SHOWN 43 0D3243 1 CBL ASSY RS485 E PNL W SEALED 44 0D3471 2 DECAL COVER DEUTSCH RECT 45 0D3471 2 DECAL COVER DEUTSCH RECT ELECTRONIC GOVERNOR HARNESS IF EQUIPPED ITEM PART NO QTY DESCRIPTION 46 0C514...

Страница 48: ...T X 8 6 0E3298 1 REDUCER 2 5 TO 3 COUPLER 7 057646C 1 FLEX EXH 2 5 X 15 44 LONG 8 0E2668 1 ELBOW EXHAUST TURBO OUTLET 9 0E3495 3 SCREW SHC M10 1 25 X 25 G12 9 10 022237 3 WASHER LOCK 3 8 10 9 7 6 4 SU...

Страница 49: ...BLOCK HEATER 5 057822 4 CLAMP HOSE 8 53 1 00 6 047411 4 SCREW HHC M6 1 0 X 16 G8 8 7 022473 4 WASHER FLAT 1 4 M6 ZINC 8 022097 4 WASHER LOCK M6 1 4 9 049813 2 NUT HEX M6 1 0 G8 YEL CHR USED ON R VOLTA...

Страница 50: ...12 AWG X 8 LONG 3 022206 1 FITTING CONDUIT STRAIGHT 3 8 48 Generac Power Systems Inc 3 1 2 BLACK WHITE GRD GND GND AC NEUT AC NEUT AC HOT AC HOT POS 34 0D3514 0D3733 Section 7 Exploded Views and Parts...

Страница 51: ...Generac Power Systems Inc 49 Section 8 Notes Generac Standby Generator Sets...

Страница 52: ...50 Generac Power Systems Inc Section 8 Notes Generac Standby Generator Sets...

Страница 53: ...Generac Power Systems Inc 51 Section 8 Notes Generac Standby Generator Sets...

Страница 54: ...anty coverage or responsibility if your non road diesel engine or a part component thereof has failed due to abuse neg lect improper maintenance or unapproved modifications or the use of counterfeit a...

Страница 55: ...time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection...

Страница 56: ...l maintenance i e tune ups associated part s adjustments loose leaking clamps installation and start up 4 Use of Non Generac replacement part s will void the warranty in its entirety 5 Any failure cau...

Страница 57: ......

Страница 58: ...A 0D5618 1 PLATE CB MOUNT S ED 390S B 0D5620 1 COVER CB TERMINALS S ED 3P C 022097 11 WASHER LOCK M6 1 4 D 022287 8 SCREW HHC 1 4 20 X 3 4 G5 E 022471 4 NUT HEX 8 32 STEEL F 022264 4 WASHER LOCK M4 G...

Страница 59: ...E FLYWHEEL 37 27 TO ENGINE TORQUE ITEM 6 24 FT LB AND USE THREAD LOCKING COMPOUND T 13717 NOTE 6 10 11 35 34 33 36 32 30 31 26 28 29 27 12 3 20 49 19 21 45 48 45 5 2 18 4 9 46 16 17 13 39 15 22 14 44...

Страница 60: ...2 12 SCREW HHC M10 1 5 X 40 G10 9 22 068113 1 CARRIER REAR BEARING 15 23 068115 1 PANEL LOWER 15 24 043123 4 WASHER LOCK M14 25 051779 4 NUT HEX M14 2 0 G8 YEL CHR 26 052259 2 WASHER FLAT M12 27 05176...

Страница 61: ......

Страница 62: ...5 E PNL W SEALED 44 0D3471 2 DECAL COVER DEUTSCH RECT 45 0D3471 2 DECAL COVER DEUTSCH RECT ELECTRONIC GOVERNOR HARNESS IF EQUIPPED 46 0C5141 2 CONN DEUTSCH GASKET 8 12 POS DT 50 022155 14 WASHER LOCK...

Страница 63: ......

Страница 64: ...14D 097962 4 SCREW SHC M6 1 0 X 25 G12 9 IN KIT 0G8108 14E 0E4351 1 GASKET ROCHESTER FUEL LEVEL GAUGE 14F 0E4352 1 GASKET ADAPTER PLATE 15 0A1492 1 CAP FUEL FILL 16 0D2670 1 NECK FUEL FILL STANDARD 4...

Страница 65: ...MOUNTING TO LOWER RADIATOR HOSE TO THERMOSTAT HOUSING 5 3 8 9 7 2 5 5 4 6 1 5 BASE 7 8 6...

Страница 66: ...ATER W WELDNUTS 3 050967 1 HOSE 5 8 ID RIA 250F 24 LG 4 0A6283 1 HOSE PREFORMED BLOCK HEATER 5 057822 4 CLAMP HOSE 8 53 1 00 6 047411 4 SCREW HHC M6 1 0 X 16 G8 8 7 022473 4 WASHER FLAT 1 4 M6 ZINC 8...

Страница 67: ......

Страница 68: ...HOSE 5 5 62 62 30 052250 1 TAPE FOAM 1 X 1 220 LG 31 0E4162 1 CAP RADIATOR 20 PSI 32 0E2671 2 RH LH SIDE AIR DUCT 3 9L MITSU 33 0E2673 2 TOP BOTTOM AIR DUCT 3 9L MITSU 34 0A2110 4 SCREW SWAGE 1 4 20 X...

Страница 69: ...9 2 8 5 7 2 RED 6 4 1 TO FLYWHEEL HOUSING BLACK OLENOID TO STARTER 2 RED 4 1 4 2...

Страница 70: ...E BATT BLK 1 X 18 00 4 065314C 1 JUMPER CABLE 33 IN 5 051756 1 SCREW HHC M10 1 5 X 20 G8 8 6 038804T 1 CABLE BATT RED 1 X 31 00 7 046526 1 WASHER LOCK M10 8 022131 1 WASHER FLAT 3 8 M10 ZINC 9 025507...

Страница 71: ......

Страница 72: ...10 1 5 X 20 G8 8 15 022131 3 WASHER FLAT 3 8 M10 ZINC 16 046526 2 WASHER LOCK M10 17 025507 1 WASHER SHAKEPROOF EXT 7 16 STL 18 024310 1 PLUG STD PIPE 1 2 STEEL SQ HD 19 0536210098 1 ASSEMBLY GROUNDWI...

Страница 73: ......

Страница 74: ...5 PPHTC SCREW M4 2 X 16 16 023827 2 BLOCK TERM JUMPER FOR S142 542 17 022158 4 NUT HEX 10 32 STEEL 18 022152 4 WASHER LOCK 10 19 022097 3 WASHER LOCK M6 1 4 20 036934 4 SCREW PPHM 10 32 X 5 8 21 0D36...

Страница 75: ......

Страница 76: ...3 8 16 X 3 4 G8 8 NZ 26 071623 12 SCREW SHC M10 1 5 X 55 G12 9 27 057642 12 SCREW HHC M10 1 5 X 40 G8 8 28 022131 14 WASHER FLAT 3 8 M10 ZINC 29 043107 4 SCREW HHC M8 1 25 X 25 G8 8 30 022129 8 WASHE...

Страница 77: ......

Страница 78: ...2 25 3 125 8 049814 4 SCREW HHC M10 1 5 X 25 G8 8 9 022131 10 WASHER FLAT 3 8 M10 ZINC 10 052859 4 NUT LOCK FL M10 1 50 11 046526 6 WASHER LOCK M10 12 0E2206 1 INSERT RUBBER REDUCER 3 X 2 25 13 051756...

Страница 79: ......

Страница 80: ...SIDE SUPPORT 57 0C3157R 1 INSULATION FRONT BRACE TOP 58 0C3157S 1 INSULATION REAR PANEL 59 0C3157T 2 INSULATION REAR CORNER POSTS 5 60 0C2643 2 DUCT DOOR GEN 2000 61 078115 48 WASHER SELF LOCKING DOME...

Страница 81: ...10 9 7 6 4 SUPPLY 3 NPT NIPPLE CUSTOMER TO 8 1 2 4 5 3...

Страница 82: ...3 059940 1 RAIN CAP 3 50 3 69 4 059936 2 ELBOW 90 D 3 NPT 5 059941 1 NIPPLE TOE 3 NPT X 8 6 0E3298 1 REDUCER 2 5 TO 3 COUPLER 7 057646C 1 FLEX EXH 2 5 X 15 44 LONG 8 0E2668 1 ELBOW EXHAUST TURBO OUTLE...

Страница 83: ......

Страница 84: ...3 00 3 19 9 055978 2 BOLT U 3 8 16 X 3 25 10 0E3495 3 SCREW SHC M10 1 25 X 25 G12 9 11 022145 18 WASHER FLAT 5 16 ZINC 12 022129 12 WASHER LOCK M8 5 16 13 022237 3 WASHER LOCK 3 8 14 0C4170 2 BRACKET...

Страница 85: ......

Страница 86: ......

Страница 87: ...B 4 TB4 7 TB4 6 TB4 8 DSUB 2 DSUB 1 CON3 4 CON2 6 CON2 5 CON2 4 CON3 3 CON3 2 CON3 14 CON3 1 CON4 1 CON4 2 CON2 13 CON2 7 CON2 14 CON2 2 SENSING 5 3 S16 S15 CON4 4 CON2 10 CON4 6 19 R4 PROG RELAY 2 PR...

Страница 88: ...CY STOP BUTTON CHARGE ALT EXCITER DIODE FIELD BOOST DIODE AVR CIRCUIT BREAKER AUDIBLE ALARM AUTOMATIC VOLTAGE REGULATOR ES1 3 D1 HZ L1 D2 ES CB1 AVR AM AA AMMETER 56 56A 57 59 67 89 CONTROL BROWN SIGN...

Страница 89: ......

Страница 90: ...R FLUID BASIN STARTER MOTOR BATTERY ALTERNATOR DC SOLENOID FUEL ENGINE HEATER GLOW PLUG SWITCH RUPTURE BASIN FLOAT GROUND 218 RED D 85 601 219 3 0 0 16 2 1 157 69 2 1 0 218 575 218 590 16 591 218 N C...

Страница 91: ......

Страница 92: ......

Страница 93: ...T TRANSFORMER CB2 CIRCUIT BREAKER 100A AS ALTERNATOR STATOR CB1 CIRCUIT BREAKER 200A E1 TO E3 240V 120 240V 1 PHASE CUSTOMER CONNECTION E3 TO 00 E1 TO 00 120V LEGEND CT2 CB2 NB B S1 NOT USED NOT USED...

Страница 94: ...XCITER FIELD TWS TWO WIRE START EA BRUSHLESS EXCITER ARMATURE TP THERMAL PROTECTOR AUTO RESET LEGEND BRUSHLESS SERIES 4 WIRE DISPLACED PHASE WINDING VOLTAGE CODE A E1A AS 00 00 CUSTOMER CONNECTION 120...