17

ITEM

PART NO.

QTY.

DESCRIPTION

1

0C8885

1

XFER SW-W 200A600V3P

2

0A9949

9

LUG SLDLSS 400-#4X1/4-20 CU7AL

3

0C4896

9

SCREW FHM M8-1.25 X 20MM CR

4

067989

9

NUT LOCK FL M8-1.25 YEL CHR

5

026902

7

SCREW HHTT #8-32 X 1/4 CZ

6

0C7907D

2

COVER LUG 3P 150/200AMP

7

045771

1

NUT HEX M8-1.25 G8 CLEAR ZINC

8

057329

1

LUG SLDLSS 350-#6X13/32 AL/CU

9

027482

1

WASHER SHAKEPROOF EXT 5/16 STL

10

022097

3

WASHER LOCK M6-1/4

11

0C8275

4

SCREW PPHM DSEMS M4-7 X 10 ZNC

12

073591

2

FUSE HOLDER

13

090388

5

SCREW HHTT M6-1.0 X 12 ZINC

14

0A1495

6

SCREW HHTT M4-0.7 X 10 BP

15

063617

1

RELAY PNL 12VDC DPDT 10A@240VA

16

047411

2

SCREW HHC M6-1.0 X 16 G8.8

17

0A1661

2

RIVET POP .156 X .675 AL

18

0C4449A

1

ASS'Y-NTRL BL150-200A

19

0E2865

1

WELDMENT,TRANSFER SWITCH BOX

20

0D3718

1

COVER, TRANSFER SWITCH BOX

21

0C8308

2

DECAL TERMINAL SHOCK HAZARD

22

0C2262

1

DECAL TERMINAL STRIP

23

0F6165

2

WASHER M6 NYLON

24

0F5569

1

DECAL,SWITCH RATING

25

064101

4

NUT LOCK FL 3/8-16

26

0E2866

1

SUBPLT 200A TS 3R

27

087680

1

NUT WING M6-1.0

28

063378

5

HOLDER CABLE TIE

29

064761

5

TIE WRAP UL 5.6 X .10 NATL

30

063321

1

HANDLE XFER SWITCH 1-400A

31

073590A

2

FUSE 5A X BUSS

32

0D3587

1

DECAL, FUSE REPLACEMENT

33

067210A

1

DECAL GROUND LUG

34

0A9457

1

DECAL NEUTRAL

35

0D4545

1

DECAL, MANUAL OPERATION

36*

0E4307

1

DECAL,TEST SEQUENCE 2P TS 3R

37

081221

1

DECAL-UL LIST HSB

38

0A2284

2

SCREW SWAGE 8-32 X 1/2 Z/YC

39

063306

1

3-PHASE POWER MONITR

40

066972

1

SOCKET RELAY OCTAL 8P 300V-10A

41**

0E4358

2

DECAL,LUG TORQUE INFO

42***

0F6521

1

DECAL TRANSFER SWITCH RTS

43

022129

1

WASHER LOCK M8-5/16

* CENTER DECAL ON INSIDE OF THE COVER (ITEM #20)
** INSTALL ACROSS E & N TERMINALS
***INSTALL ON FRONT OF THE COVER (ITEM #20)

Section 6 — Exploded Views and Parts List

Generac GTS “W” Type Transfer Switch

200 A, 3-pole Switch Assembly – Drawing No. 0E4312$-F

Содержание 004635-1

Страница 1: ...POWER SYSTEMS INC Owner s Manual GTS W Type Automatic Transfer Switch 200 Amp 250 Volts Model Nos 004635 1 004635 2 This manual should remain with the unit...

Страница 2: ...source failure occurs must be isolated from the NORMAL utility power source by means of an approved transfer switch Failure to properly isolate the NORMAL and STANDBY power sources from each other may...

Страница 3: ...e standing on metal or concrete place insulative mats over a dry wood platform Work on this equipment only while standing on such insulative mats Never work on this equipment while physically or menta...

Страница 4: ...eason codes require it in all standby electric system installations 1 3 TRANSFER SWITCH DATA DECAL A DATA DECAL is permanently affixed to the transfer switch enclosure Use this transfer switch only wi...

Страница 5: ...o be connected to it Mount the switch vertically to a rigid supporting structure To prevent switch distortion level all mounting points If necessary use washers behind mounting holes to level the unit...

Страница 6: ...r LOAD leads to switch termi nals T1 T2 T3 Conductors must be properly supported of approved insulative qualities protected by approved conduit and of the correct wire gauge size in accordance with ap...

Страница 7: ...anually or the manual handle could be damaged 3 2 1 CLOSE TO NORMAL SOURCE SIDE Before proceeding verify the position of the switch by observing window A in Figure 3 1 on page 6 If win dow A reads ON...

Страница 8: ...te AC voltmeter and frequency meter check the no load voltage and frequency Single phase generator supply Measure across ATS terminal lugs E1 to E2 E1 to NEUTRAL and E2 to NEUTRAL a Frequency 60 62 Hz...

Страница 9: ...er load as follows Turn ON electrical loads to the full rated wattage amperage capacity of the generator DO NOT OVERLOAD With maximum rated load applied check voltage and frequency across transfer swi...

Страница 10: ...Systems Inc Section 4 Mounting Dimensions Generac GTS W Type Transfer Switch Mounting Dimensions Drawing No 0D3714 B 180 514 612 490 430 Values are in Millimeters Note Diameter of Mounting holes A is...

Страница 11: ...ECTED UTILITY 1 N1 UTILITY 2 N2 LOAD 2 T2 23 194 CB1 NEUTRAL CONNECTION N1 N2 T1 T2 2 T E1 E2 2 E NEUTRAL LUG TRANSFER SWITCH UTILITY SUPPLY WITH SERVICE DISCONNECT LOAD CUSTOMER 194 23 LOAD 2 UTILITY...

Страница 12: ...RED LS2 LS3 LS1 T1 T2 2 3 5 6 1 4 C CONTACTOR ACTUATING COIL GTS TRANSFER SWITCH CONTACTOR LS1 LS2 LS3 LIMIT SWITCHES ACTUATOR TR RELAY TRANSFER TS TERMINAL STRIP CUSTOMER CONNECTION N1A F2 N2 N1 F1 N...

Страница 13: ...E2 E1 N2A 205 N1A 205 E1 E1 A 7 1 B 9 3 T1 T2 N1A N2A 126 205 N1A N1A N1A N1A F2 F1 23 194 TS UTILITY 2 UTILITY 1 194 23 23 194 23 194 N1 N2 N2A N2A N2A N2A N2A N2A N1A 23 194 Section 5 Electrical Dat...

Страница 14: ...RANSFER SWITCH CONTACTOR LS1 LS2 LS3 LIMIT SWITCHES ACTUATOR PM POWER MONITOR 3 PHASE UTILITY TR RELAY TRANSFER TS TERMINAL STRIP CUSTOMER CONNECTION 3 4 5 N1B N2A N3 PM N1B N1A PM F2 N2 N1 F1 N1B N2A...

Страница 15: ...B 9 3 6 T1 T2 N1B N2A N3 E3 T3 2 1 8 7 3 4 5 6 126 205 N2A N2A N2A N1B N1B N1B N1B N1A N3 PM N3 N3 N1B N1B F2 F1 23 194 TS UTILITY 2 UTILITY 1 N2A N2A N2A N3 N3 N3 194 23 23 194 23 194 N1 N2 N2A N2A...

Страница 16: ...0C8884 LS 0C7907H S 0C7907H S 0C7907H S A A GROUND LUG ASSEMBLY DETAIL A A ENCLOSURE C8308X C8308X C8308X 0D4545 0A9949 S 0A9949 S 0A9949 T 0A9949 T SUPPLIED W SWITCH HANDLE P N 063321 0A9949 S 0 0 A9...

Страница 17: ...2 SCREW TH FRM M6 1X16 N WA Z JS 17 0A1661 2 RIVET POP 156 X 675 AL 18 0C4449A 1 ASS Y NTRL BL150 200A 19 0E2865 1 WELDMENT TRANSFER SWITCH BOX 20 0D3718 1 COVER TRANSFER SWITCH BOX 21 0C8308 2 DECAL...

Страница 18: ...2 16 23 27 20 6 35 17 14 12 32 31 38 30 33 Replace with UL listed fuse of same 600 Volt 5 amp type and rating 0D3587 37 NEUT 34 C8308X GROUND LUG ASSEMBLY DETAIL A A 25 9 43 13 10 18 21 13 6 15 14 19...

Страница 19: ...X 21 0C8308 2 DECAL TERMINAL SHOCK HAZARD 22 0C2262 1 DECAL TERMINAL STRIP 23 0F6165 2 WASHER M6 NYLON 24 0F5569 1 DECAL SWITCH RATING 25 064101 4 NUT LOCK FL 3 8 16 26 0E2866 1 SUBPLT 200A TS 3R 27 0...

Страница 20: ...r to July 1 2004 2 Costs of normal maintenance i e tune ups associated part s adjustments loose leaking clamps installation and start up 3 Any failure caused by contaminated fuels oils coolants antifr...