SPECIFICATIONS

Maximum Surge Watts  . . . . . . . . . . . . . .6,250 watts
Continuous Wattage Capacity  . . . . . . . . .5,000 watts
Power Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous Load Current

At 120 Volts  . . . . . . . . . . . . . . . . . . . . .41.7 Amps
At 240 Volts  . . . . . . . . . . . . . . . . . . . . .20.8 Amps

Phase  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-phase
Rated Frequency  . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity  . . . . . . . . . . . . . . .5 U.S. gallons

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure

that all periodic maintenance tasks are completed on a

timely basis; that all discrepancies are corrected; and

that the unit is kept clean and properly stored. 

Never

operate a damaged or defective generator.

Engine Maintenance

See engine manual for instructions.

Generator Maintenance

Generator maintenance consists of keeping the unit

clean and dry. Operate and store the unit in a clean

dry environment where it will not be exposed to

excessive dust, dirt, moisture or any corrosive vapors.

Cooling air slots in the generator must not become

clogged with snow, leaves or any other foreign

material.

NOTE: Do Not

use a garden hose to clean generator.

Water can enter engine fuel system and cause

problems. In addition, if water enters generator

through cooling air slots, some of the water will be

retained in voids and cracks of the rotor and stator

winding insulation. Water and dirt buildup on the

generator internal windings will eventually decrease

the insulation resistance of these windings.

To Clean the Generator

• Use a damp cloth to wipe exterior surfaces clean.
• Soft, bristle brush may be used to loosen caked on

dirt or oil.

• A vacuum cleaner may be used to pick up loose dirt

and debris.

• Low pressure air (not to exceed 25 psi) may be

used to blow away dirt. Inspect cooling air slots and

opening on generator. These openings must be kept

clean and unobstructed.

STORAGE INSTRUCTIONS

The generator should be started at least once every

seven days and allowed to run at least 30 minutes. If

this cannot be done and you must store the unit for

more than 30 days, use the following guidelines to

prepare it for storage.

Generator Storage

• Clean the generator as outlined in “To Clean the

Generator.”

• Check that cooling air slots and openings on

generator are open and unobstructed.

DANGER!

Storage covers can be flammable.

Do Not

place a storage cover over a hot

generator. Let the unit cool for a sufficient time

before placing the cover on the unit.

Engine Storage

See engine owner’s manual for instructions.

Other Storage Tips

•

Do Not

store gasoline from one season to another.

• Replace your gasoline can if it starts to rust. Rust

and/or dirt in a gasoline can cause problems when

you use contaminated fuel with this unit.

• Store in clean and dry area.

Содержание pp5000t

Страница 1: ...witch if this unit is used for backup power Failure to isolate the generator from the power utility may result in injury or death to electric utility workers and damage to the generator due to a backfeed of electrical energy The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manua...

Страница 2: ... load When adequate engine power is not available engine life may be shortened SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have any questions about your generator s application ask your Dealer or consult the factory The manufacturer could not possibly anticipat...

Страница 3: ...on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the engine generator with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loads before shutting down the generator Do Not insert any object through cooling ...

Страница 4: ...cle is provided with a circuit breaker to protect the generator against electrical overload Breakers are push to reset type Engine Control Switch Puts engine in starting mode Shuts off a running engine Fuel Shut Off Valve Controls fuel supply to engine Fuel Tank Capacity of 5 U S gallons 19 liters Grounding Wing Nut Provides a tie point for connecting the generator frame to earth ground KNOW YOUR ...

Страница 5: ... stud in the same manner NOTE Be sure to install the wheel with raised hub inboard Tip unit and install the wheel Retain wheel on axle stud with a flat washer and retaining pin Install other wheel on remaining axle stud in the same manner Remove two front nuts and lock washers from vibration mount with 13 mm wrench Use these nuts to attach the support leg Center the lifting handle on generator end...

Страница 6: ......

Страница 7: ...it is in a level position Open the fuel shut off valve Move the choke lever to the Full choke position Figure 4 Set the engine control switch to the On position Figure 5 The engine on your unit is equipped with a Climate Control system Use as described below Above 32 F turn the air cleaner clockwise until it stops Make sure the arrow on the top of the engine aligns with the sun symbol on the air c...

Страница 8: ...amps of all loads to be connected at one time This total should not be greater than the rated wattage amperage capacity of the generator See Don t Overload the Generator on page 10 Stopping the Engine Unplug all electrical loads from generator panel receptacles Never start or stop engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilize the...

Страница 9: ...ng Receptacle Use a NEMA L14 20 plug with this receptacle Connect a 4 wire cord set rated for 250 Volts at 20 AC Amps or greater to the plug Figure 9 You can use the same 4 wire cord if you plan only to run a 120 Volt load Use this receptacle to operate 120 Volt or 240 Volt AC 60 Hz single phase loads at 20 Amps This outlet is protected by a 20 Amp push to reset circuit breaker 120 Volt 30 Amp Loc...

Страница 10: ...tage when selecting electrical devices to connect to your generator First figure the watts needed to start the largest motor Add to that figure the running watts of all other connected loads Items in the wattage reference guide Figure 11 are provided to help you to determine how many items the generator can operate at one time Recreational Home Uses Tool Appliance Watts AM FM clock radio 50 Light ...

Страница 11: ...of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp cloth to wipe exterior surfaces clean Soft bristle brush may be used to loosen caked on dirt or oil A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 ...

Страница 12: ...rk plug 7 Water in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain gas tank and fill with fresh fuel 5 Connect wire to spark plug 6 Replace spark plug 7 Drain gas tank fill with fresh fuel 8 Put choke lever to no choke position 9 Fil...

Страница 13: ...Generac Portable Products PP5000T Generator 13 ELECTRICAL SCHEMATIC ...

Страница 14: ...Generac Portable Products PP5000T Generator 14 WIRING DIAGRAM ...

Страница 15: ...005A 2 PIN Retaining 2 87280 2 WHEEL 8 Diameter 3 93728 2 STUD Axle 4 94222Q 2 JAM NUT Lock 5 8 18 5 49808 2 WASHER Flat 6 94034 1 LEG Mounting 8 B84910 1 HANDLE Lifting 9 75928 1 GRIP Handle 10 39287 2 HHCS M8 1 25 x 45 11 52858 2 NUT Locking Hex M8 1 25 EXPLODED VIEW WHEEL KIT ...

Страница 16: ...Generac Portable Products PP5000T Generator 16 EXPLODED VIEW GENERATOR ...

Страница 17: ...74 1 TANK Gas Plastic 5 Gal 29 93826 1 DECAL Operating Instructions 30 78831B 4 CAPSCW Hex Hd M6 x 60 Item Part Qty Description 31 94834 1 CAP with Fuel Gauge 32 77395 4 NUT Hex Lock M6 33 78299 1 BUSHING Plastic Tank 34 80270 1 VALVE Plastic Tank 35 81897 1 PANEL Control 36 81919 1 PANEL Control Back Plastic 37 68868 1 OUTLET 120 Volt 30 Amp Locking 38 68867 1 OUTLET 120 240 Locking 39 68759 1 OU...

Страница 18: ...Generac Portable Products PP5000T Generator 18 NOTES ...

Страница 19: ...Generac Portable Products PP5000T Generator 19 NOTES ...

Страница 20: ...ing overspeeding improper maintenance repair or storage so as in the COMPANY s judgment to adversely affect its performance and reliability THERE IS NO OTHER EXPRESS WARRANTY THE COMPANY HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLIED WARRANTIES WHIC...

Отзывы: