background image

4

PowerBoss 5,500 Watt Storm-Plus Generator

Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended oil and fuel.

If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-270-1408.

IMPORTANT: Any attempt to run the unit before it has
been serviced with the recommended oil will result in an
engine failure.

REMOVE GENERATOR

FROM CARTON

• Set the carton on a rigid flat surface with “This Side Up”

arrows pointing upward.

• Carefully open the top flaps of the shipping carton.

• Cut down corners at one end of carton from top to

bottom and lay that side of carton down flat.

• Remove all packing material, carton fillers, etc.

• Remove the generator from the shipping carton.

CARTON CONTENTS

Check all contents. If any parts are missing or damaged, call
the generator helpline at 1-800-270-1408.
• The generator
• Generator and engine owner’s manuals
• Locking 30 Amp plug
• Engine oil
• Wheel kit

INSTALL WHEEL  KIT

IMPORTANT:This wheel kit is not intended for
over-the-road use.

To install your wheel kit you need the following tools:

• Two 13mm box, open end, or socket wrenches

Install Wheel Kit as follows:

1.

Place the bottom of the generator cradle on a flat,
even surface.Temporarily place unit on blocks to ease
assembly.

2.

Slide axle through both axle mounting brackets on
cradle frame, as shown in Figure 2.

Mounting Leg

Use Existing Fasteners

Axle

Flat Washer

Cap Screw

Handle Assembly

Hex nut

Wheel

Retaining Pin

Figure 2 — Install Wheel Kit

Содержание PowerBoss 5500 Watt Storm Plus

Страница 1: ... Obey all safety messages that follow this symbol to avoid possible injury or death Questions Help is just a moment away Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Sat 8 4 CT Web www generac portables com or www briggsandstratton com Model No 1642 0 5 500 Watt AC Generator Manual No 189027 Revision 2 06 01 2001 ...

Страница 2: ...or is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modify the unit or use it for any application it was not designed for If you have any questions about your generator s application ask your dealer or consult the...

Страница 3: ...ance on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected devices turned ON Start the engine and let it stabilize before connecting any electrical loads Disconnect all electrical loads before shutting down the generator Do Not insert any object through cooling slots o...

Страница 4: ...on down flat Remove all packing material carton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30 Amp plug Engine oil Wheel kit INSTALL WHEEL KIT IMPORTANT This wheel kit is not intended for over the road use To i...

Страница 5: ...al lubrication for the life of the bearing Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the generator engine Do Not use premium gasoline Do Not mix oil with gasoline Clean a...

Страница 6: ...protect the generator against electrical overload Fuel Tank Capacity of five 5 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 3 Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch off engine Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester scree...

Страница 7: ...oper oil level in crankcase This unit is equipped with a Low Oil Shutdown System See engine manual Refer to the engine owner s manual for complete starting instructions Connecting Electrical Loads Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads Do Not connect 240 Volt loads to the 120 Volt ...

Страница 8: ...ush to reset circuit breaker CAUTION Although this outlet states it has a 120 240Volt 30 Amp rating up to 7 200 watts the generator is only rated for 5 500 watts Powering loads that exceed the wattage amperage capacity of the generator can damage it or cause serious injuries 120 Volt AC 20 Amp Duplex Receptacles Each receptacle Figure 8 is protected against overload by a 20 Amp push to reset circu...

Страница 9: ... lasts for only a few seconds when starting such motors Be sure you allow for this high starting wattage when selecting electrical devices to connect to your generator First figure the watts needed to start the largest motor Add to that figure the running watts of all other connected loads Recreational Home Uses Tool Appliance Watts AM FM clock radio 50 Light bulb 100 Fan 200 20 color TV 400 Deep ...

Страница 10: ...use skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture o...

Страница 11: ...n the Generator Check that cooling air slots and openings on generator are open and unobstructed CAUTION Storage covers can be flammable Do Not place a storage cover over a hot generator Let the unit cool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips Do Not store gasoline from one season to another Replace ga...

Страница 12: ... plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Overchoking 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Fill crankcase to proper level 3 Clean or replace air cleaner 4 Fill fuel tank 5 Drain gas tank and fill with fresh fuel 6 Connect wire to spark plug 7 Replace spark plug 8 Drain gas tank ...

Страница 13: ...PowerBoss 5 500 Watt Storm Plus Generator 13 NOTES ...

Страница 14: ...14 PowerBoss 5 500 Watt Storm Plus Generator SCHEMATIC ...

Страница 15: ...PowerBoss 5 500 Watt Storm Plus Generator 15 WIRING DIAGRAM WARNING TAB MUST NOT BE BROKEN ...

Страница 16: ...16 PowerBoss 5 500 Watt Storm Plus Generator EXPLODED VIEW MAIN UNIT ...

Страница 17: ... 32 91825 1 ASSEMBLY Brush Holder 33 66849 2 TAPTITE M5 0 8 x 16 34 B4871 1 COVER Bearing Carrier 35 22769 1 WASHER 10 Int Shakeproof 36 86494 1 SCREW M6 1 0 x 16 Wing Item Part Qty Description 37 B2153 13 SCREW 10 Self Drilling 38 189155 4 WASHER Flat 6 6 x 21 6 x1 9 39 188973 4 GROMMET Tank 40 189156 4 HHCS M6 1 0 x 25 41 80270 1 VALVE Tank 42 78299 1 BUSHING Plastic Tank 43 85134 1 CAP Fuel Gau...

Страница 18: ...IEW AND PARTS LIST WHEEL KIT Item Part Qty Description 1 B4217 1 ASSEMBLY Handle 2 B1764 1 LEG Mounting 3 52858 2 NUT Locking Hex M8 1 25 4 39287 2 HHCS M8 1 25 x 45 5 93693H 1 AXLE 6 B4966 2 WHEEL 10 Diameter 7 87005A 2 PIN Retaining 8 22247 2 WASHER Flat ...

Страница 19: ...7 x 10mm 3 82308 6 SCREW Self Tapping 4 82881 2 WASHER Internal Lock 5 23365 6 WASHER No 8 Serrated Lock 6 43437 1 OUTLET 120 240 Locking 30 Amp 7 38150 6 WASHER No 8 Flat 8 22264 6 WASHER No 8 Lock 9 51715 6 NUT M4 0 7 Hex 10 75207 2 CIRCUIT BREAKER 20 amp 11 68759 2 OUTLET 120 Volt 20 amp Duplex 12 81919 1 CONTROL PANEL Back Plastic 13 22694 1 CONNECTOR 6 Pin ...

Страница 20: ...antizado para juegos estándares por la Agencia de Protección Ambiental Para mayor información acerca de la garantía consulte con el manual del propietario del motor INSTRUCCIONES DE SEGURIDAD Este generador fue diseñado y fabricado para usos específicos No intente modificar la unidad o usarla para otro uso para el cual no fue diseñado Si usted tiene alguna pregunta acerca del uso del generador pre...

Страница 21: ...l generador incluso cuando la unidad esté funcionando en exteriores de otra forma podría dañar la unidad Nunca arranque o detenga el motor generador cuando tenga cargas eléctricas conectadas a los tomacorrientes y los dispositivos conectados estén ENCENDIDOS Arranque el motor y permita que se estabilice antes de conectar las cargas eléctricas Desconecte todas las cargas eléctricas antes de apagar ...

Страница 22: ...rial de empaque relleno etc Saque el generador de la caja de envío CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no está presente o está dañada por favor llame a la linea de ayuda para generadores al 1 800 270 1408 La unidad principal Manual del propietario Aceite para motor Tapones de fijación Juego de llantas INSTALE EL JUEGO DE RUEDAS IMPORTANTE Este Juego de Ruedas no h...

Страница 23: ...esté en funcionamiento o caliente No encienda cigarrillos o fume cuando esté llenando el tanque del combustible ADVERTENCIA No llene excesivamente el tanque de combustible Deje suficiente espacio para la expansión del combustible Use gasolina regular SIN CONTENIDO DE PLOMO en el generador No use gasolina premium No mezcle aceite con gasolina Limpie el área alrededor del llenado de gasolina retire ...

Страница 24: ...del motor y está equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentación eléctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminación eléctrica de 120 Voltios AC a 20 A...

Страница 25: ...el cigüeñal Esta unidad está equipada con un Sistema que se apaga cuando el aceite esté bajo Consulte con el manual del motor Consulte con el manual del propietario del motor para las instrucciones completas de encendido Conexion De Cargas Electricas Deje que el motor se estabilice y se caliente por unos minutos después del arranque Conecte y encienda las cargas eléctricas de 120 y o 240 Voltios A...

Страница 26: ... del tipo empuje para reposicionar PRECAUCIÓN Aunque esta salida tiene una clasificación de 120 240Voltios 30 Amps hasta 7 200 vatios el generador está clasificado solamente para 5 500 vatios Cargas que pasen la capacidad de amperaje y vataje del generador pueden dañarlo o causar accidentes muy serios 120 Volt AC 20 Amp Receptáculos Dobles Cada receptáculo Figura 17 está protegido en contra de sob...

Страница 27: ...os dispositivos eléctricos que va a conectar a su generador Primero conozca la cantidad de vatios necesarios para dar arranque al motor más grande Sumele a ese número los vatios de funcionamiento de todas las otras cargas conectadas Uso Recreativo Doméstico Herramienta Artefacto Watts Radio AM FM con reloj 50 Bombillo de luz 100 Ventilador 200 Televisor de color 20 400 Congeladora 500 Computadora ...

Страница 28: ...ar el generador El agua podría introducirse en el sistema de combustible del motor y causar problemas Además si el agua se introduce al generador a través de las ranuras para aire de enfriamiento algo del agua quedará retenida en los espacios vacíos y grietas del aislamiento del devanado del estator y rotor La acumulación de agua y suciedad en los devanados internos del generador disminuirá eventu...

Страница 29: ...29 PowerBoss 5 500 Watt Storm Plus Generador NOTAS ...

Страница 30: ...a 7 Agua en la gasolina 8 Sobrecebado 9 Mezcla de combustible excesivamente rica 10 La válvula de corte de combustible 11 La válvula de entrada está atascada está cerrada 12 El motor ha perdido compresión 1 Coloque del interruptor en On 2 Limpie o reemplace el depurador de aire 3 Llénelo con combustible fresco 4 Drene el tanque de gasolina llénelo con combustible fresco 5 Conecte el cable a la buj...

Страница 31: ...negligencia accidentes sobrecarga exceso de velocidad mantenimiento inadecuado reparación o almacenamiento que según el punto de vista de la COMPAÑÍA afecte de una manera negativa su rendimiento y fiabilidad NO EXISTE OTRA GARANTÍA EXPRESA LA COMPAÑÍA POR LO TANTO NIEGA CUALQUIER O TODAS LAS GARANTÍAS IMPLICADAS INCLUYENDO PERO NO LIMITADAS A AQUELLAS DE MERCADEO Y ESTADO FÍSICO PARA UN PROPÓSITO ...

Страница 32: ...rmal maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in the COMPANY s judgement to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices the generator...

Отзывы: