![Generac Portable Products 2700PSI 1676-0 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/generac-portable-products/2700psi-1676-0/2700psi-1676-0_owners-manual_2208906015.webp)
15
Generac 2700 PSI Pressure Washer
TROUBLESHOOTING
Problem
Cause
Correction
Pump has following
problems: failure to produce
pressure, erratic pressure,
chattering, loss of pressure,
low water volume.
1. Low pressure spray tip installed.
2. Water inlet is blocked.
3. Inadequate water supply.
4. Inlet hose is kinked or leaking.
5. Clogged inlet hose strainer.
6. Water supply is over 100°F.
7. High pressure hose is blocked or
leaks.
8. Gun
leaks.
9. Nozzle is obstructed.
10. Pump is faulty.
1. Replace spray tip with high pressure
spray tip.
2. Clear
inlet.
3. Provide adequate water flow.
4. Straighten inlet hose, patch leak.
5. Check and clean inlet hose strainer.
6. Provide cooler water supply.
7. Clear blocks in outlet hose.
8. Replace
gun.
9. Clean
nozzle.
10. Contact Generac service facility.
Detergent fails to mix with
spray.
1. Detergent siphoning tube is not
submerged.
2. Chemical filter is clogged or
cracked.
3. Dirty in-line filter.
4. High pressure spray tip installed.
1. Insert detergent siphoning tube into
detergent.
2. Clean or replace filter/detergent
siphoning tube.
3. See “Check In-Line Filter” on page 13.
4. Replace spray tip with low pressure
spray tip.
Engine runs good at no-load
but “bogs” when load is
added.
Engine speed is too slow.
Move throttle control to FAST position. If
engine still “bogs down”, contact Briggs and
Stratton service facility.
Engine will not start; or
starts and runs rough.
1. Low oil level.
2. Dirty air cleaner.
3. Out of gasoline.
4. Stale
gasoline.
5. Spark plug wire not connected to
spark plug.
6. Bad spark plug.
7. Water
in
gasoline.
8. Overchoking.
9. Excessively rich fuel mixture.
10. Intake valve stuck open or closed.
11. Engine has lost compression.
1. Fill crankcase to proper level.
2. Clean or replace air cleaner.
3. Fill fuel tank.
4. Drain gas tank; fill with fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain gas tank; fill with fresh fuel.
8. Open choke fully and crank engine.
9. Contact Briggs and Stratton service
facility.
10. Contact Briggs and Stratton service
facility.
11. Contact Briggs and Stratton service
facility.
Engine shuts down during
operation.
Out of gasoline.
Fill fuel tank.
Engine lacks power.
Dirty air filter.
Replace air filter.
Engine “hunts” or falters.
Choke is opened too soon.
Move choke to halfway position until