![Generac Mobile MFH900 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/generac-mobile/mfh900/mfh900_owners-manual_2208805026.webp)
22
Owner’s Manual for Flameless Air Heater
Operation
Starting Engine and Heater
This section applies both to MANUAL and AUTO modes.
NOTE:
The unit starts in the mode in which it was last
shut down.
1.
Perform
.
2.
Close all doors.
3.
Switch positive air shutdown to OFF (O).
4.
Switch battery disconnect to ON (I).
5.
Attach ducting to unit.
6.
On control panel, switch MAIN POWER to ON (I).
7.
See
. Wait for controller to display
OK
To Crank Engine
(A).
Figure 3-1. OK to Crank Engine
8.
On control panel, press PUSH TO START button.
Unit engine starts and begins HTF warm-up.
During HTF warm-up, controller displays
Wait –
Heater Warming
).
Figure 3-2. HTF Warm-Up
9.
See
. Wait for controller to display
Heater Run
.
Figure 3-3. Heater Run
10.
Adjust air output temperature and heater CFM.
Adjusting Air Output Temperature
This section applies both to MANUAL and AUTO modes.
1.
Verify unit is fully operational—controller must
display
Heater Run
.
2.
See
. Adjust temperature by pressing
Increase
(A) or
Decrease
(B).
Figure 3-4. Air Output Temperature Adjustment
•
In AUTO
mode,
choose
one
of
three
temperatures—120, 150, or 180 °F.
•
In MANUAL mode, choose any output temperature
between 120 and 180 °F.
Adjusting Heater CFM
This section applies both to MANUAL and AUTO modes.
1.
Verify unit is fully started—controller must display
Heater Run
.
2.
See
. Adjust heater CFM by pressing
Increase
(A) or
Decrease
(B).
Figure 3-5. Heater CFM Adjustment
•
In AUTO mode, choose Low, Medium, or High.
NOTE:
In AUTO mode, selected temperature
determines what heater CFM setpoints are avail-
able. See
for more informa-
tion.
•
In MANUAL mode, choose any CFM between
2,800 and 4,900.
OK to Crank Engine
CAUTION
(000230)
Equipment Damage. Do not continuously crank
engine for more than ten seconds. Doing so will lead
to overdischarge of batteries and starter seizure.
Wait - Heater Warming
Heater Run
Heater Run
A
B
Heater Run
A
B
Содержание MFH900
Страница 4: ...iv Owner s Manual for Flameless Air Heater This page intentionally left blank ...
Страница 24: ...20 Owner s Manual for Flameless Air Heater General Information This page intentionally left blank ...
Страница 28: ...24 Owner s Manual for Flameless Air Heater Operation This page intentionally left blank ...
Страница 40: ...36 Owner s Manual for Flameless Air Heater Troubleshooting This page intentionally left blank ...
Страница 41: ...Owner s Manual for Flameless Air Heater 37 Section 6 Wiring Diagrams Main Control System ...
Страница 42: ...38 Owner s Manual for Flameless Air Heater Wiring Diagrams Perkins Engine Aftertreatment GROUP G ...
Страница 44: ...40 Owner s Manual for Flameless Air Heater Wiring Diagrams Trailer Harness Electric Brakes GROUP G ...
Страница 46: ...42 Owner s Manual for Flameless Air Heater Wiring Diagrams ...
Страница 48: ...44 Owner s Manual for Flameless Air Heater Wiring Diagrams This page intentionally left blank ...
Страница 49: ...Owner s Manual for Flameless Air Heater 45 Wiring Diagrams This page intentionally left blank ...
Страница 50: ...46 Owner s Manual for Flameless Air Heater Wiring Diagrams This page intentionally left blank ...
Страница 51: ......