Operation
22
MLT6SM/K-8SK Operating Manual
17973 G
CONTROL PANEL RECEPTACLES
The control panel is equipped with multiple receptacles
for running accessories or tools from the generator.
Power is supplied to the receptacles any time the engine
is running and the main circuit breaker is switched to the
ON (I) position.
Note: Do not pull more than 1000W from each receptacle
when the lights are on. This will overload the generator
and cause the main circuit breaker to trip. Should the
breaker trip, switch off the lights, remove some of the load
to the receptacles and wait 10 minutes for the bulbs to
cool before turning them back on.
With all of the lights off, the full generator output may be
used with the 240V twist-lock receptacle.
Figure 13 - Location of Receptacles
SHUTTING DOWN THE UNIT
Prior to shutting down the unit, check with personnel using power supplied by the unit and let them know the power
is going to be turned off. Make sure the power shut down will not create any hazards by accidentally turning off
equipment that needs to be kept on (pumps, compressors, lights, etc.).
When you have finished using the unit, proceed with shut down as follows:
1. Remove any loads from the receptacles.
2. Switch the individual circuit breakers for each light and
each
receptacle to the OFF (O) position.
3. Switch the main circuit breaker to the OFF (O) position.
4. Turn the Control Power switch to the OFF (O) position.
Figure 14 - Breakers and Control Power Switch
Note: For extended storage time, disconnect the battery. For extended storage requirements, refer to the engine
operator’s manual.
AUTOMATIC SHUTDOWN
This unit is equipped with a low oil pressure and high coolant temperature automatic shutdown system. This system
will automatically shut off the fuel supply to stop the engine if oil pressure drops too low or the engine exceeds normal
operating temperature. Return the Control Power switch to the
(stop) position to reset the unit after you have
determined the cause of the shutdown.
00762
240V Twist-Lock
Receptacle
120V GFCI
Receptacles
00763
CONTROL POWER SWITCH
STOP
15 SEC.
MAX.
CIRCUIT BREAKERS
I
O
I
O
I
O
I
O
MAIN
BREAKER
240V
I
O
I
O
STOP
Содержание MLT6SK
Страница 4: ...iv This Page Intentionally Left Blank ...
Страница 12: ...Safety 6 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Страница 22: ...General Information 16 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Страница 32: ...Operation 26 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Страница 34: ...Maintenance 32 MLT6SM K 8SK Operating Manual 17973 G This Page Intentionally Left Blank ...
Страница 36: ......