![Geneq SXBlue II Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/geneq/sxblue-ii/sxblue-ii_technical-reference-manual_2208797078.webp)
SXBlue II GPS Series Technical Reference Manual
63
• Set the configuration to its board-level defaults (refer to the table below)
Configuration (Command)
Setting
Elevation Mask ($JMASK)
5
Residual Limit ($JLIMIT)
10
Altitude Aiding ($JALT)
None
Age of Differential ($JAGE)
45 minutes
Air Mode ($JAIR)
Auto
Differential Type ($JDIFF)
Default for Application
NMEA Precision ($JNP)
5 decimals
COG Smoothing ($JTAU,COG)
None
Speed Smoothing ($JTAU,SPEED)
None
The board-level defaults are different than the factory default settings. The configuration
files for factory default settings are found as Utilities in the supplied CD-ROM.
This message has the following format:
$JRESET<CR><LF>
$JRESET,ALL<CR><LF>
does everything $JRESET does, plus it clears almanacs.
$JRESET,BOOT<CR><LF>
does everything $JRESET,ALL does, plus the following:
• Clears use of the Real-Time clock at startup
• Clears use of backed-up ephemeris and almanacs
• Re-boots the receiver when done
When the ‘,ALL’ field is present (without the square brackets), the almanac is also
defaulted. Issuing this command with this optional data field is not usually necessary.
4.2.14 $JSAVE
Sending this command is required after making changes to the configuration of the
SXBlue II GPS receiver.
This command has the following structure:
$JSAVE<CR><LF>
The SXBlue II GPS will reply with the following two messages. Ensure that the receiver
indicates that the save process is complete before turning the receiver off or changing
the configuration further.
$> Saving Configuration. Please Wait...