background image

4

necessary when the monitors are placed near room boundaries. 

The attenuation levels are -2 dB, -4 dB and -6 dB.

Treble Tilt Control

Treble Tilt control allows adjusting the treble response above 5 

kHz by +2 dB, -2 dB or -4 dB, which can be used for correcting 

an excessively bright or dull sounding system or to compensate 

for high frequency level loss if the monitor is placed behind a 

screen. 

LED Disable

This switch shuts off the front panel LED light.

ISS

This switch activates or deactivates the ISS automatic power 

saving function. The default time for ISS activation is 60 

minutes, but can be adjusted in GLM.

Figure 3. The location of the acoustic axis is on the center-

line of the monitor at the given height “h”. 

Figure 4. Symmetrical layout and keeping the acoustic 

axis clear from obstructions minimizes reflection surfaces 

and maintains accurate localisation because reflections are 

symmetrical.

Figure 5. Recommended distances from a single wall to the 

front baffle of free-standing monitors. Correct (green) and 

not recommended (red).

Figure 6. Recommended monitor positioning for 5.1 multi-

channel audio reproduction

Min 5 cm

Avoid

> 60 cm

Max

60 cm

ACOUSTIC

AXIS

> 0

,7

m

h

8350A: h=290 mm (11 1/2

)

in

Содержание SAM 8350A

Страница 1: ...8350A Operating Manual ...

Страница 2: ...mple stereo to very complex 3D immersive audio setups including also one or more subwoofers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup a...

Страница 3: ...ut off frequency Attenuation levels of 2 dB 4 dB or 6 dB both switches ON can be selected Desktop 160 Hz The desktop low frequency control switch 5 attenuates the bass frequencies around 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control Th...

Страница 4: ...SS automatic power saving function The default time for ISS activation is 60 minutes but can be adjusted in GLM Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Fi...

Страница 5: ...s For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance Therearenouserserviceablepartsinsidethemonitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour Indication Solid greed Normal state normal operation Blinking green G...

Страница 6: ...earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Free flow of air behind the m...

Страница 7: ...ted noise level in free space at 1 m on axis A weighted 5 dB Harmonic distortion at 90 dB SPL at 1 m on axis Freq 50 100 Hz 100 Hz 2 0 5 Drivers Bass Treble All drivers are magnetically shielded 205 mm 8 in cone 25 mm 1 in metal dome Weight 12 8 kg 28 2 lb Dimensions Height Width Depth Height with Iso Pod 433 mm 171 16 in 286 mm 111 4 in 278 mm 1015 16 in 452 mm 1713 16 in and on the user is encou...

Страница 8: ...put power Long term output power is limited by driver protection circuitry 200 W 150 W Amplifier system THD at nominal output 0 01 System Signal to Noise ratio A weighted Bass Treble 109 dB 112 dB Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 12 W 230 W 8350A Analog signal input connector XLR female balanced 10 kOhm Maximum analog input signal Anal...