background image

Choosing and installing  

the loudspeaker cables

The RAM1 amplifier unit has separate 
power amplifiers for the tweeter and woofer. 
Accordingly, there are two pairs of binding 
posts, white (-) and red (+) for the tweeter and 
black (-) and grey (+) for the woofer. At the 
loudspeaker end, the cables are connected 
to a screw block terminal, which plugs into 
the input connector on the loudspeaker   
enclosure. Be sure to maintain correct 
polarity when connecting the loudspeaker 
cables and be extra careful not to mix the 
tweeter and woofer cables (See Figure 7).

Use a good quality 4-conductor cable and 

make the cable runs as short as possible. 
See Table 1 for recommended cable gauges. 
The terminals accept a cable up to 6 mm

2

 

(9 gauge).

If you are installing the AIW26B system 

to  an  existing  wall,  examine  the  walls 
thoroughly for the shortest and least 
obstructed cable route. Be careful to avoid 
cutting  or  drilling  into  electrical  wires, 
ventilation or water pipes. These are often 
visible in the attic, basement or crawl space 
below the floor. It is a good idea to route the 
loudspeaker cables away from electric or 
video cables, which might induce hum into 
the loudspeaker system.

Connecting the RAM1 

amplifier

The RAM1 amplifier is designed to be 
connected to a line level output of a 
preamplifier,  Surround  Sound  processor 
or other low level source. NOTE! Never 

connect the RAM1 to a loudspeaker level 
output of a power amplifier! 
Before making 
the  connections,  check  that  the  voltage 
selector on the amplifier’s back panel is set 
to the correct voltage and the power on all 
components is turned off. 

Start by connecting the loudspeaker 

cables to the amplifier’s binding posts (see 
Fig.  7  and  9).  Check  that  the  amplifier’s 
serial number matches that of the AIW26B 
loudspeaker enclosure which it will power. 
The number can be found on a sticker on 
the loudspeaker’s reflex port and on the 
amplifier’s top cover. If the loudspeakers 
are  not  yet  installed,  make  a  note  of 
which amplifier is connected to each 
channel. Check the cable polarity and use 
the provided cable binding post tool to 
tighten the binding posts. Be careful not to 
overtighten the binding posts as they may 
be damaged.

The RAM1 has two parallel 10 kOhm 

input connectors: a balanced XLR and 
an unbalanced RCA. For longer cable 
connection lengths (>10m or >30ft) a 
balanced line connection is recommended 
as it offers better immunity to external 
interference. The RCA connection 
method usually works as well for shorter 
connection lengths in less electrically noisy 
environments. Do not use both inputs at the 
same time. Consult your Genelec dealer for 
the choice of signal cables.

The RAM1 has a provision for remote 

controlled switching between “ON” and 
“STANDBY” modes (not available in units 
sold in the EU). The “REMOTE CONTROL” 

connector block has two connector pairs: 
1-2 for a 12 V DC trigger remote control 
and 3-4 for an external switch or relay type 
(contact closure) remote control (see Table 
2). Do not connect two remote controls to 
the amplifier at the same time.

Space requirement for the 

RAM1 amplifier

The dual 120 W power amplifiers of a RAM1 
unit generate a large amount of heat when 
used  at  full  power.  To  avoid  overheating, 
ensure that there is good airflow around the 
amplifier and no external heat sources close 
to it. We recommend installing the RAM1 
into a well ventilated equipment rack using 
its dedicated RM1 4U rack mount kit. 

If the RAM1 amplifier is placed in a 

cabinet, on a shelf or into an equipment rack 
without its dedicated RM1 rack mount kit, 
there must be at least 100 mm (4 in) of free 
space behind, 150 mm (6 in) above and 50 
mm (2 in) on both sides of the amplifier to 
ensure adequate cooling (see figure 10). 

Mounting the RAM1 amplifier 

to an equipment rack

We recommend that you use the Genelec 
RM1 4U rack mount kit when installing the 
RAM1 amplifier in an equipment rack. Make 
sure that the space above and below the 
RAM1 is uncluttered and there is a space of 
100 mm (4 in) or more behind the amplifier. 
The space behind the amplifier must be 
well ventilated. If the temperature inside 
the rack is likely to rise close to the RAM1’s 
maximum  ambient  temperature  of  35°  C 
(95° F), we recommend installing ventilation 
fans to ensure that the thermal protection 
is not activated prematurely. See figure 11.

Setting the input sensitivity

The input sensitivity of each amplifier can 
be made to match that of the decoder or 
other source by use of the input sensitivity 
control on the amplifier’s front panel (see 

+

WOOFER

+

TWEETER

WOOFER

TWEETER

-

+

-

+

TWEETER

WOOFER

Figure 6. The metal mesh grille is held in 
place by magnets.

Figure 7. Correct loudspeaker cable polarity.

Cable gauge

Max. length

2,0 mm

2

 (14 AWG)

30 m (100 ft)

3,3 mm

2

 (12 AWG)

40 m (130 ft)

5,3 mm

2

 (10 AWG)

60 m (200 ft)

Table 1. Recommended cable thicknesses 
for different lengths of loudspeaker cable.

Содержание aiw26b

Страница 1: ...Operating Manual AIW26B ...

Страница 2: ... dealer for recommended installation companies in your region Matching loudspeakers and amplifiers Each AIW26B loudspeaker unit has been factory calibrated for optimum performance with the RAM1 amplifier it is shipped with Never mix these matched amplifier loudspeaker systems in the installation process The matching units are marked with the same ID number on the reflex port of the AIW26B enclosur...

Страница 3: ... position as outlined in chapter Loudspeaker placement Examine the wall structure carefully to find a clearly unobstructed location for the loudspeaker The loudspeaker enclosure requires a minimum of 102 millimeters 4 in of free depth measured from the surface of the drywall Note that the grille is slightly wider and taller than the hole and requires about 30 millimeters 1 1 16 in of smooth wall s...

Страница 4: ... a balanced line connection is recommended as it offers better immunity to external interference The RCA connection method usually works as well for shorter connection lengths in less electrically noisy environments Do not use both inputs at the same time Consult your Genelec dealer for the choice of signal cables The RAM1 has a provision for remote controlled switching between ON and STANDBY mode...

Страница 5: ... environment and personal taste See Table 3 for suggested room response control settings If the sound is found subjectively too bright set treble tilt to 2 dB if too bass heavy set bass tilt to 2 dB The adjustment is done by setting the three groups of room response control switches treble tilt bass tilt and bass roll off on the front panel of the amplifier The manufacturer default settings for al...

Страница 6: ...iderations Servicing and adjustment must only be performed by qualified Genelec service personnel Do not undo any screws on the amplifier unit It is forbidden to use this product with an unearthed power cable which may lead to personal injury To prevent fire or electric shock do not expose any part of the system to water or moisture Do not place any objects filled with liquid such as vases on the ...

Страница 7: ...6 in of smooth wall surface around all sides of the cut out Depth Free space requirement inside the wall cavity measured from the surface of the drywall Bass amplifier output power Short term 120 W Treble amplifier output power Short term 120 W Input impedance 10 kOhm Crossover frequency 3 5 kHz Treble tilt control in 2 dB steps from 2 to 4 dB MUTE 15 kHz Bass roll off control in 2 dB steps from 0...

Страница 8: ... 83881 Fax 358 17 812 267 Email genelec genelec com In the U S please contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code ...

Отзывы: