background image

minimised by placing the loudspeaker clear of 
reflective  surfaces.  For  instance,  putting  the 
loudspeakers on stands behind and above the 
mixing console and tilting them down to point 
the acoustic axes to ear level at the listening 
position usually gives a better result than plac-
ing the loudspeakers on the meter bridge.   

Minimum clearances

Sufficient cooling for the amplifier and function-
ing of the reflex port must be ensured if the 
loudspeaker is installed in a restricted space 
such  as  a  cabinet  or  integrated  into  a  wall 
structure. The surroundings of the loudspeaker 
must always be open to the listening room with 
a  minimum  clearance  of  5  centimeters  (2”) 
behind, above and on both sides of the loud-
speaker. The space adjacent to the amplifier 
must either be ventilated or sufficiently large to 
dissipate heat so that the ambient temperature 
does not rise above 35 degrees Celsius (95°F) 

Mounting options

The  8020A  offers  several  mounting  options:  
The  Iso-Pod™  (Isolation  Positioner/Decou-
pler™) vibration insulating table stand allows 
tilting  the  loudspeaker  for  correct  alignment 
of the acoustic axis. On the base of the loud-
speaker is a 3/8” UNC threaded hole compat-
ible with a standard microphone stand. On the 
rear there are two M6x10 mm threaded holes 
for Omnimount

®

 size 20.5 brackets or the key-

hole wall mount adapter provided with the loud-
speaker.

Maintenance

No user serviceable parts are to be found within 
the amplifier unit. Any maintenance or repair of 
the 8020A unit should only be undertaken by 
qualified service personnel. 

Safety considerations

Although the 8020A has been designed in ac-
cordance with international safety standards, 
the  following  warnings  and  cautions  should 
be observed to ensure safe operation and to 
maintain the loudspeaker under safe operating 
conditions:

•  Servicing and adjustment must only be 
  performed by qualified service personnel. 
  The loudspeaker must not be opened.
•  Do not use this product with an unearthed 
  mains cable or an unearthed mains 
  connection as this may compromise 
  electrical safety.
•  Do not expose the loudspeaker to water or 
  moisture. Do not place any objects filled with
  liquid, such as vases on the loudspeaker or 
  near it. 
•  This loudspeaker is capable of producing 
  sound pressure levels in excess of 85 dB, 
  which may cause permanent hearing 
  damage.
•  Free flow of air behind the loudspeaker is 
  necessary to maintain sufficient cooling. 
  Do not obstruct airflow around the 
  loudspeaker.
•  Note that the amplifier is not completely 
  disconnected from the AC mains service 
  unless the mains  power cord is removed 
  from the amplifier or the mains outlet.

Guarantee

This product is guaranteed for a period of one 
year against faults in materials or workmanship. 
Refer to supplier for full sales and guarantee 
terms.

Содержание 8020A

Страница 1: ...Genelec 8020A Active Monitoring System Operating Manual 8020A ...

Страница 2: ...tic environ ments If necessary the bass response of the 8020A s can be extended with a Genelec 7050B subwoofer Positioning the loudspeaker Each 8020A monitor is supplied with an inte grated amplifier unit mains cable and an oper ating manual After unpacking place the loud speaker in its required listening position taking note of the line of the acoustic axis The axes of all loudspeakers should con...

Страница 3: ... the volume control on the front panel When the volume control knob is turned fully counter clockwise the 8020A goes into stand by mode The loudspeaker can be left in stand by mode whenever it is not used however it is only completely disconnect ed from the mains power when the mains cable is disconnected Setting the tone controls The frequency response of the Genelec 8020A can be adjusted to matc...

Страница 4: ...on Measure or listen systematically through the different combinations of settings to find the best frequency balance Mounting considerations Align the loudspeakers correctly Always place the loudspeakers so that their acoustic axes see figure 1 are aimed towards the listening position Only vertical placement is preferred as it minimises acoustical cancella tion problems around the crossover frequ...

Страница 5: ...e 20 5 brackets or the key hole wall mount adapter provided with the loud speaker Maintenance No user serviceable parts are to be found within the amplifier unit Any maintenance or repair of the 8020A unit should only be undertaken by qualified service personnel Safety considerations Although the 8020A has been designed in ac cordance with international safety standards the following warnings and ...

Страница 6: ...e Bass Tilt Treble Tilt and Bass Roll Off controls on the free field response of the 8020A Figure 5 The upper curve group shows the horizontal directivity characteristics of the 8020A measured at 1 m The lower curve shows the system s power response ...

Страница 7: ...shielded Weight 3 7 kg 8 1 lb Dimensions Height 242 mm 91 2 including Iso Pod table stand Height 230 mm 91 16 without Iso Pod table stand Width 151 mm 6 Depth 142 mm 55 8 Connectors Input XLR female balanced 10 kOhm pin 1 gnd pin 2 pin 3 Output XLR male balanced 100 Ohm Pin 1 gnd pin 2 pin 3 Input level for 100 dB SPL output at 1 m 6 dBu at volume control max Volume control range 80 dB relative to...

Страница 8: ...lease contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Genelec China Representative Office Soho New Town 88 Jianguo Road D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 2180 Fax 86 10 8580 2181 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O...

Отзывы: