Table 1. Recommended cable gauges for 
different lengths of signal cable.

in large immersive installations with bass 
management of surround channels, one 
9301A is required per 7382A.

Analog Output 1 and 2

Analog balanced XLR connectors connect 
the subwoofer to the monitors. 

These analog outputs carry an unfiltered 

copy of the inputs. The subwoofer/main 
monitor crossover is adjusted in the GLM 
software from 50 Hz to 100 Hz in 5 Hz 
increments. 

See chapter "Bass Management" for 

details.

THRU AES/EBU

The THRU AES/EBU is a bit-to-bit copy of 
the digital audio signal on the IN Digital. This 
output can be used for digital sharing of the 
audio between subwoofers in the case where 
multiple subwoofers are used. This output 
can also be used for distributing a stereo 
digital audio signal to monitors, creating a 
2.1 digital audio stereo monitoring system. 

Subwoofer Connector

This Speakon connector is used for 
linking the RAM-SW amplifier unit and the 
7382A subwoofer enclosure. There is a 
corresponding connector on the reflex port 
end of the enclosure. 

Figure 1. Connector panel of the RAM-SW amplifier unit.

Cable Gauge

Max. Length

4 x 2.0 mm

2

 (14 AWG)

30 m / 100 ft

4 x 2.5 mm

2

 (13 AWG)

40 m / 130 ft

4 x 3.3 mm

2

 (12 AWG)

50 m / 165 ft

4 x 4.0 mm

2

 (11 AWG)

60 m / 200 ft

SUBWOOFER
CONNECTOR

CONNECT ONLY TO GENELEC NETWORK

CONTROL NETWORK

MAINS INPUT
50 / 60 Hz 1100 W
100 - 120 V~
220 - 230 V~

LFE IN

IN

THRU

SERIAL NUMBER

RAM-SW AMPLIFIER

MODULE

www.genelec.com

MADE IN FINLAND

LED CONNECTOR

This device complies
with FCC Part 15 and
Canadian ICES-003
radio frequency Class
A emission
requirements. Refer
to operating manual
for full information.

2

1 3

OUT / THRU

IN

1

1

2 3

3

2

-

GND

+

IN 1

OUT 1

IN 2

OUT 2

ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT
SUBJECT TO WATER OR MOISTURE. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
PERSONNEL. USE EARTHED MAINS CONNECTION ONLY.

WARNING

RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS
EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À
L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER
TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. CET
APPAREIL DOIT ÊTRE RACCORDÉ À LA TERRE.

AVERTISSEMENT

LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA VARUSTETTUUN
PISTORASIAAN. APPARATET MÅ TILKOPLES JORDET
STIKKONTAKT. APPARATEN SKALL ANSLUTAS TILL JORDAT
UTTAG.

THIS AMPLIFIER HAS BEEN CALIBRATED FOR USE WITH THE
LOUDSPEAKER MARKED WITH THE SAME SERIAL NUMBER.
DO NOT MIX THE CALIBRATED AMPLIFIER/LOUDSPEAKER
PAIRS ! TURN OFF POWER BEFORE DISCONNECTING
LOUDSPEAKER CONNECTIONS !

NOTE !

DIGITAL AES/EBU

ANALOG

ANALOG LFE

CHANNEL

INPUT

ANALOG SIGNAL INPUTS

AND OUTPUTS 1 AND 2

DIGITAL AES/EBU
IN AND THRU
CONNECTORS

GLM CONTROL
NETWORK
CONNECTORS

REMOTE LED
CONNECTOR

SUBWOOFER
CONNECTOR

MAINS
CONNECTOR

Figure 2. GLM Network cabling. Audio cabling not shown.

LISTENING

POSITION

MICROPHONE

GLM
NETWORK

GLM
NETWORK

GLM
NETWORK

USB

RAM-SW

RAM-XL

RAM-XL

Max. Room 

volume

m

3

 (ft

3

)

Front monitors 

Stereo & LCR

Subwoofers for  

2-channel Stereo

Subwoofers for  

>5-channel Immersive

125 (4400)

S360

2x 7380 (1)

3x 7380 or 1x 7382 (1)

125 (4400)

1237

2x 7380 (1)

3x 7380 or 1x 7382 (1)

125 (4400)

1238DF

2x 7380 (1)

3x 7380 or 1x 7382 (1)

170 (6000)

1238 / AC

3x 7380 or 7382 (1)

1-2x 7382 (1)

200 (7000)

1234 / AC

7382 (1)

2x 7382 (1)

400 (14000)

1236

2x 7382 (2)

2-3x 7382 (2)

1) Additional subwoofers of the same type may be required in a larger room with bass heavy program 

material.
2) Subwoofers are not necessarily required for a 1236A installation as these monitors are already full 

range. For immersive systems, subwoofers can be used to reproduce the LFE channel.

Table 2. Recommended subwoofer/main monitor combinations.

Содержание 7382A

Страница 1: ...Genelec 7382A Smart Active Subwoofer Operating Manual 7300 Series ...

Страница 2: ...lied with an individually calibrated RAM SW amplifier unit If several 7382A subwoofers are used in the same system it is very important not to mix the subwoofer amplifier pairs A mains cable a 10 m 33 3 ft Speakon signal cable one 5 m GLM network cable and this operating manual are also included Operating Environment This subwoofer is designed for indoor use only The permissible ambient temperatur...

Страница 3: ...CTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL USE EARTHED MAINS CONNECTION ONLY WARNING RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR NE PAS EXPOSER À L EAU OU L HUMIDITÉ AUCUN COMPOSANT À L INTÉRIEUR REMPLAÇABLE PAR L UTILISATEUR ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ CET APPAREIL DOIT ÊTRE RACCORDÉ ...

Страница 4: ...with the GLM network is presented in the GLM System Operating Manual System Setup The 7382A SAM subwoofer reaches its full potential when set up and calibrated using the GLM software Genelec Loudspeaker Manager GLM and the proprietary Genelec monitor management network offer automated acoustic equalization individually for every monitor and subwoofer automated level alignment distance acoustic tim...

Страница 5: ... cooling Make the recess 20 cm 8 in wider than the subwoofer Place the subwoofer to the right side of the recess if the driver is facing the room This leaves sufficient free space at the reflex port side The height and depth of the recess should not be much bigger than what is needed as this may cause unwanted acoustic effects Using Multiple Subwoofers Multiple Genelec 7382A subwoofers can be coup...

Страница 6: ...ntain sufficient cooling Do not obstruct airflow around the subwoofer This subwoofer is capable of producing sound pressure levels in excess of 85 dB which may cause a permanent hearing damage Compliance to FCC Rules This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any ...

Страница 7: ... field In half space the output will be 6 dB higher in relation to distortions Fundamental frequency 0 20 40 60 80 100 10 200 20 30 50 100 Hz Level vs Freq Hz 7382A 27 8 18 dB SPL 2nd harmonic 3rd harmonic 0 20 40 60 80 100 10 200 20 30 50 100 Hz Level vs Freq Hz 7382A 27 8 18 LFE channel Main channels dB SPL Figure 8 The delay variation of the 7382A ...

Страница 8: ...male balanced 10 kOhm Maximum analog input signal Analog input sensitivity 100 dB SPL at 1 m pin 1 gnd pin 2 non inverting pin 3 inverting 24 0 dBu 6 dBu Digital signal input connector XLR female 110 Ohm Digital signal output Thru connector XLR male 110 Ohm Digital audio input Word length Sample rate Digital input sensitivity 100 dB SPL at 1 m Positive input gain selection GLM control AES EBU Sing...

Страница 9: ...Figure 9 The signal path block diagram of the 7382A ...

Страница 10: ......

Страница 11: ......

Страница 12: ...ontact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genelec...

Отзывы: