Genelec 7360A and 7370A

Smart Active Subwoofers

Operating Manual

7300 Series

750-7360A/7370A

Содержание 7360A

Страница 1: ...Genelec 7360A and 7370A Smart Active Subwoofers Operating Manual 7300 Series 750 7360A 7370A ...

Страница 2: ...Bass management splits the signal from each input into low and high frequency components Signal content below the crossover frequency is reproduced by the subwoofer and signal content above the crossover frequency is reproduced by the monitors connected to the outputs of the subwoofer The 7360A and 7370A offer two bass management methods Centralized bass management This method builds both the high...

Страница 3: ...er When using this method run each signal cable first to the subwoofer Then run the respective output to the monitor This monitor feed signal is highpass filtered at 85 Hz When using the LFE signal run the LFE signal to the subwoofer LFE in connector When daisy chaining multiple subwoofers run a cable from the Link Out connector the next subwoofer s Link In IN 3 IN 4 OUT 3 OUT 4 IN 5 OUT 5 IN 6 IN...

Страница 4: ...ency response of the whole system at the crossover frequency Figure 3 shows the effect of phase difference to the frequency response The phase difference between the main monitors and subwoofer at the listening position depends on the position of the subwoofer so the phase adjustment should be done only after the preferred position is found and subwoofer and monitor levels have been aligned GLM so...

Страница 5: ...should not be much bigger than needed for ventilation as this may cause unwanted acoustic effects Maintenance There are no user serviceable parts inside the subwoofer Maintenance or repair must only be done by a Genelec certified service Guarantee Genelec guarantees the subwoofers for two years against manufacturing faults or defects altering performance Refer to the reseller for full sales and gu...

Страница 6: ...Bass Roll Off 4 8 and 12 dB dB SPL 0 20 40 60 80 100 10 200 20 30 50 100 Hz Level vs Freq Hz 7370A 25 4 16 LFE channel Main channels Bass Roll Off 4 8 and 12 dB dB SPL Figure 5 The curves above show the main channel s frequency response with 85 Hz lowpass filtering the fre quency response of the LFE channel and the effect of the Bass Roll Off adjustment to the response of the 7360A Figure 6 The cu...

Страница 7: ...Standby ISS active Idle Full output peak 1 W 15 W 300 W 1 W 20 W 400 W SIGNAL PROCESSING SECTION Analog signal input connector XLR female balanced 10 kOhm Maximum analog input signal Analog input sensitivity 100 dB SPL at 1 m rotary level adjustment pin 1 gnd pin 2 non inverting pin 3 inverting 25 0 dBu 12 to 6 dBu Digital signal input connector XLR female 110 Ohm Digital signal output Thru connec...

Страница 8: ... Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genelec Sveri...