background image

General

The Genelec 5041A Active In-Wall subwoofer 
system  consists  of  a  subwoofer  enclosure 
and  a  matched  RAM3  remote  amplifier 
module. It has been designed to the same 
rigorous  standards  as  Genelec’s  high-per-
formance  HT  series  active  Home Theater 
loudspeakers. 

Unpacking

When unpacking, check that nothing is miss-
ing or damaged in transit. If there is a problem 
with the product, contact your local Genelec 
dealer.  A  Genelec  5041A  system  includes 
the following items:

•  5041A enclosure unit
•  Grille frame and grille insert
•  Four mounting brackets
•  RAM3 amplifier unit
•  M4x16  and  M4x30  thumb  screws  
  for the grille frame
•  Plastic washers for the thumb screws
•  Mains power cable
•  One  4-pole  and  one  2-pole  cable 
  connector
•  12  4,2x32  screws  for  the  mounting  
  brackets

Installation

We recommend that you use the services of 
an authorized installation specialist for the 
installation of the 5041A subwoofer. 

Choosing the Location  

for the Subwoofer

Usually the best place for the subwoofer is 
slightly offset from the centerline of the wall. 
Positioning the subwoofer near a corner will 
boost the bass level at lower frequencies and 
may  cause  asymmetrical  spatial  imaging. 
When using multiple subwoofers connected 
together using the LINK OUT connectors on 
the RAM3 amplifiers, the subwoofer enclo-
sures should be placed close to one another 
to achieve efficient summing of the signal. 

Subwoofer Cabling

A 2-conductor cable needs to be run between 
the RAM3 amplifier and the subwoofer enclo-
sure. Two cable connectors are supplied with 
the loudspeaker system, a four-pole connec-

tor to fit the connector on the amplifier and a 
two-pole connector to fit the respective input 
at the bottom of the subwoofer enclosure. 

Use a good quality 2-conductor cable and 

make  the  cable  runs  as  short  as  possible. 
See Table 1 for recommended cable gauges. 
The connectors accept a cable up to 6 mm

(9 gauge) thick. 

Attach the cables to the connectors pro-

vided with the kit. Be sure to maintain cor-
rect polarity when connecting the cables. The 
correct  pin  sequences  are  marked  on  the 
amplifier and subwoofer connectors. Start-
ing from the top, the first two poles on the 
4-pole amplifier connector are + and - for the 
subwoofer and 3 and 4 provide connection 
to a 12 V trigger remote control. Secure the 
cable to the strain relief tie next to the loud-
speaker connector.

Rout the cables away from electric, video 

or  phone  cables,  which  might  induce  hum 
into the system.

Installing the Subwoofer 

Enclosure

The  Genelec  5041A  subwoofer  enclosure 
is  designed  for  floating  installation  using 
the  provided  mounting  brackets  that  pre-
vent  unwanted  vibration  transfer  from  the 
subwoofer to the wall structure. The enclo-
sure is held in place by rubber springs, clear 
of any fixed part of the wall.

The  woofer  protection  cover  should  be 

left in place until the drywall is installed. It 
provides a cut-out template for the drywall 
installers and protects the bass drivers during 
all stages of work.

Before  the  installation,  make  sure  that 

there  is  sufficient  space  for  the  subwoofer 
in the chosen location. The minimum dimen-
sions are:

1. Free depth between the sheetrock (=width 
of the wall studs) 89 mm (3

1

/

2

")

2. Free vertical space 1308 mm (51

1

/

2

")

3.  Free  horizontal  space  between  the  wall 
studs 360 to 440 mm (14

3

/

16

" to 17

3

/

8

")

First attach the two lower brackets. Note 

that  the  lower  edge  of  the  cut-out  will  be 
140 mm (5

1

/

2

") above the lowest edge of the 

bracket. 

The flanges on the bracket correspond to 

the  minimum  permissible  mounting  depth. 
Attach the brackets to the studs so that the 
edge  of  the  flange  is  level  with  the  inside 
edge of the stud. This will automatically pro-
vide sufficient clearance for the subwoofer.

Next connect the subwoofer cable to the 

connector  at  the  bottom  of  the  subwoofer 
enclosure and position the enclosure on the 
lower  brackets. The  rubber  springs  on  the 
bracket fit the grooves on the bottom of the 
enclosure.

Secure the subwoofer in place by attach-

ing the top brackets to the studs. Align them 
in the same way as the lower brackets and 
ensure that the rubber springs press against 
the  bottom  of  the  grooves,  holding  the 
subwoofer firmly in position.

Check  the  positioning  of  the  enclosure 

by placing a level on the studs at different 
heights. Check also that the enclosure is not 
touching any other part of the wall structure. 
As the enclosure may vibrate when played 
at  high  output  levels,  a  clearance  of  at 
least 3 mm (1/8") is required between the 
subwoofer  enclosure  and  drywall  or  any 
other  solid  part  of  the  wall.  Slight  adjust-
ments  can  be  made  by  carefully  bending 
the brackets. 

Installing the drywall

The protective cover on the bass drivers pro-
vides a template for the cut-out. Measure its 
location and cut an opening in the sheetrock 
accordingly. 

Installing the Grille

Once  the  drywall  is  installed,  remove  the 
bass driver protective cover by unscrewing 
the three Phillips screws holding it in place. 
Attach  the  grille  frame  with  three  thumb 
screws. NEVER use the Phillips screws! Do 
not tighten the thumb screws more than is 
needed to hold the frame in place. Be care-

Cable gauge

Max. length

2,0 mm

2

 (14 AWG)

30 m (100 ft)

3,3 mm

2

 (12 AWG)

40 m (130 ft)

5,3 mm

2

 (10 AWG)

60 m (200 ft)

Table 1. Recommended cable thicknesses for 
different lengths of cable

Genelec 5041A Active In-Wall Subwoofer

Содержание 5041A

Страница 1: ...Operating Manual 5041A Genelec 5041A Active In Wall Subwoofer ...

Страница 2: ...stallation using the provided mounting brackets that pre vent unwanted vibration transfer from the subwoofer to the wall structure The enclo sure is held in place by rubber springs clear of any fixed part of the wall The woofer protection cover should be left in place until the drywall is installed It provides a cut out template for the drywall installers and protects the bass drivers during all s...

Страница 3: ...hat the amplifier s serial number matches that of the subwoofer enclo sure which it will power The RAM3 has two 10 kOhm signal input connectors a balanced XLR and an unbal anced RCA For long cable connection lengths 10m or 30ft a balanced line connection is recommended as it offers better immunity to external interference However the RCA connection method usually works as well for shorter connecti...

Страница 4: ...cluttered and there is a space of 100 mm 4 or more behind the amplifier The space behind the amplifier must be well ventilated If the temperature inside the rack is likely to rise close to the maximum ambient tempera ture of 35 C 95 F we recommend install ing ventilation fans to ensure that the thermal protection is not activated prematurely Attach the RAM3 to the RM2 rack mount with two M4 screws...

Страница 5: ...UTO START function which automatically turns the amplifier to STANDBY mode if an input signal has not been detected for approximately 30 minutes and back to ON mode when the signal returns The function can be deactivated by turning the AUTO START dip switch to OFF A two colour LED on the amplifier panel indicates the amplifier status green for ON and yellow for STANDBY The amplifier mode can also ...

Страница 6: ...ection CONNECTORS system specifications 5041A Free field frequency response 3 dB 35 Hz 95 Hz Maximum short term sine wave SPL output averaged from 40 to 85 Hz measured in half space at 1 meter 105 dB Maximum peak SPL output with random pink noise measured in half space at 1 meter 110 dB Self generated noise level in half space at 1 m on axis A weighted 15 dB Drivers 2 x 165 mm 6 5 Weight Subwoofer...

Отзывы: