Genelec 1032C Скачать руководство пользователя страница 2

2

Introduction

Congratulations and a thank you for the purchase of this 

Genelec Smart Active Monitor™ (SAM™) system. This manual 

addresses the stand-alone setup and use of the 1032C SAM 

monitor. This monitors can also be set up and used with the 

Genelec Loudspeaker Manager GLM™ and the proprietary 

Genelec monitor control network and software, offering much 

more versatile acoustic settings and features. Use with the 

GLM™ is described in the GLM™ System Operating Manual.

All Genelec SAM systems are designed to integrate easily 

into all professional environments, supporting both standard 

analog line level audio and AES/EBU formatted digital audio 

signals. 

The 1032C is suitable for professional monitoring tasks 

demanding high precision and reliability of monitoring. 

The Directivity Control Waveguide™ (DCW™) technology 

provides excellent frequency balance even in difficult acoustic 

environments.

Each monitor is supplied with a mains cable, one 5 m GLM 

network cable and an operating manual.

Energy saving Intelligent Signal Sensing (ISS™) can be turned 

on to put the monitor automatically into a deep sleep state 

where the product consumes less than one Watt of power. Upon 

sensing an input signal the monitor automatically wakes up to 

full operation. The wait until entering the ISS power save can be 

configured using the GLM software. When the ISS is active you 

can have your monitoring system ready for action at all times. 

System setup using GLM™ Control 

Network

Although the 1032C can be used without the GLM™ software 

and control network, they only reach their full potential when 

set up and calibrated using the GLM™ software. Genelec 

Loudspeaker Manager GLM™ and the proprietary Genelec 

monitor control network and software offer automated acoustic 

equalization and alignment for any reproduction system from 

simple stereo to very complex 3D immersive audio setups 

including also one or more subwoofers. GLM setup is fast and 

accurate. The settings can be controlled with a computer or be 

permanently stored in the monitors to make the setup available 

at all times even when a computer is not in use. Genelec 

recommends setting up SAM monitoring systems using GLM. 

You can find a detailed description of the setup and the use of 

GLM™ in the GLM™ System Operating Manual.

The setup is fast and consists of the following steps:

•  Connect a CAT5 (RJ45) cable between each monitor (and 

subwoofer) and finally to the control network input of the 

GLM Adapter device (see Figure 1). 

•  Connect the GLM Adapter device to computer USB 

connector. 

•  Using a microphone stand, place the Genelec measurement 

microphone at the listening location with the microphone 

pointing upwards and the microphone top at the height of the 

engineer’s ear. The microphone is a part of the GLM User Kit.

•  Connect the microphone cable to the microphone input in 

the GLM Adapter device.

•  Download the GLM software at the Genelec web site (www.

genelec.com). 

•  Install the GLM software and follow the instructions in the 

software to measure and set up your monitors. 

•  If you plan to not use a computer for controlling the 

monitors, use the GLM software to write the setting into the 

monitors (use menu item “Store | Store the Current Group 

Settings…”). 

While the GLM network is disconnected the settings stored 

using the Genelec Loudspeaker Manager software can be 

selected in use by setting the STORED switch ON.  

Setup without using the GLM

When GLM is not available, you can use the settings on the 

monitor for system setup. These settings are limited but provide 

the basic acoustical calibrations and input selection. To use this 

method, set the STORED switch OFF.  

Содержание 1032C

Страница 1: ...1032C Smart Active Monitor Operating Manual ...

Страница 2: ...ol network and software offer automated acoustic equalization and alignment for any reproduction system from simple stereo to very complex 3D immersive audio setups including also one or more subwoofers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Ge...

Страница 3: ...aisy chaining up to four monitors Figure 2 Connectors and controls on the back panel of a 1032C SMART ACTIVE MONITOR ANALOG IN DIGITAL THRU AES EBU DIGITAL IN AES EBU GLM NETWORK MAINS INPUT 50 60 Hz 200 W 100 240 V WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL USE EARTHED MAINS CONNECTION ONLY ...

Страница 4: ...front panel LED light ISS This switch activates or deactivates the ISS automatic power saving function The default time for ISS activation is 60 minutes but can be adjusted in GLM Digital The Digital switch selects the digital audio channels on the AES EBU Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid overloading the monitor If the AE...

Страница 5: ... Normal state normal operation Blinking green GLM is adjusting the monitor Green blink every 10 sec Monitor is an ISS power saving sleep state Red blink Power amplifier overload protection is active audio is modified because of protection Solid red Monitor is muted Yellow Monitor is not in the active playing group Yellow blinking Overheat protection is active audio is modified because of protectio...

Страница 6: ...00 1k 2k 5k 10k Frequency Hz Genelec Oy 1032C 2 Mar 17 0 60 15 30 45 85 90 95 100 70 75 80 85 90 95 dB SPL dB SWL 20k 50 100 200 500 1k 2k 5k 10k Frequency Hz Genelec Oy 1032C 2 Mar 2017 ms 5 0 10 15 35 20 25 30 40 interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Страница 7: ...PROCESSING SECTION 1032C Bass amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver protection circuitry 250 W 150 W Amplifier system THD at nominal output 0 05 Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 11 W 200 W 1032C Analog signal input connector XLR female balanced 10 kOhm Max...

Страница 8: ...enelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd B33 101 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District 100015 Beijing China Phone 86 10 5823 2014 400 700 1978 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O Box 2306 S...

Отзывы: