Страница 1: ...Genelec 1031A Monitoring System Operating Manual 1031A ...
Страница 2: ...erating manual After unpacking place the speaker so that its acoustical axis see figure 2 is aimed towards the listening position Do not place the speaker in a horizontal position as this may cause acoustical cancellation problems around the crossover frequency Sufficient cooling for the amplifier must be ensured if the speaker is installed in a restricted space such as a cabinet or inte grated in...
Страница 3: ...o water or moisture Do not place any objects filled with liquid such as vases on the speaker or near it 4 Note that the amplifier is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet WARNING This equipment is capable of producing sound pressure levels in excess of 85 dB which may cause permanent hearing damage Access...
Страница 4: ...in 3 Input impedance 10 kOhm balanced Input level for 100 dB SPL output 1m variable from 6 to 6 dBu Input level for maximum short term sine wave output of 110 dB SPL 1m variable from 16 to 4 dBu Subsonic filter below 45 Hz 18 dB octave Ultrasonic filter above 25 kHz 12 dB octave Crossover frequency Bass Treble 2 2 kHz Crossover acoustical slopes 24 dB octave Treble tilt control operating range in ...