Amber filter

The upper panel is the amber
filter used to observe the gel 
upon being lowered in position. 

Dented holder

A long, dented holder, which is 
located close to the operator, 
is used to store the gel-cutting knife.  

Power inlet

is used for connecting 
the power cord. 

Light source

The light source is located below and 
projects upward from the bottom. 
Please first lower the amber filter in 
position when in use for preventing the 
strong light from harming the eyes. 

Ventilation holes

are located on the same side 
and enable the heat, which is 
generated when power is on, 
to be displaced. 

ON/OFF button

is used for switching 
on and off the power.

BLooK LED transilluminator

Operating 

1. Place the BLooK LED transilluminator on a level bench, with enough space around 

 

the unit for allowing air circulation and preventing overheating. 

P.03

Содержание BK001

Страница 1: ......

Страница 2: ...gned ergonomic 4 angle so users can easily sit on a chair to see the experiment results BLooK is designed to view the gel after running electrophoresis on the gel stained with the Novel Juice Novel Gr...

Страница 3: ...0 Hz Built in blue light LED module 30 000 470 25 C 25 C 40 C 5 Amber filter ideal for Novel Juice Novel Green Novel Green Plus OnePCRTM OnePCRTM HiFi OnePCRTM HotStar OnePCRTM Plus OneMark B OneMARK...

Страница 4: ...and projects upward from the bottom Please first lower the amber filter in position when in use for preventing the strong light from harming the eyes Ventilation holes are located on the same side and...

Страница 5: ...h gel and staining agents 4 Close the amber lid above the gel 5 Press the ON OFF to ON mode 6 Now the fluorescent samples can be viewed or cut Note For cutting fluorescent samples out of the gel pleas...

Страница 6: ...Reactions 100 Reactions 600 l 600 l 10 ml 100x 500 mL Troubleshooting Refer to the table below to troubleshoot problems that you may encounter when viewing with the BLooK LED transilluminator Related...

Страница 7: ...PARE BLADE for taking out the new replacement blade Insert it into the X shaped blade insertion hole Restore the blue connector back into the original position and then screw tight the blue part with...

Страница 8: ...isk of danger Consult the User Guide for further safety information Do not dispose of this product in unsorted municipal waste Caution To minimize negative environmental impact from disposal of electr...

Страница 9: ...ld be noted that published literature has identified blue light as a possible risk factor for macular degeneration however no clinical studies have been published Therefore the BLooK LED transillumina...

Страница 10: ...Made in TAIWAN CHINA Patent CN203115668U TAIWAN Patent M449283...

Отзывы: