10.3 Product Service 
GenBody Inc. 
3-18, Eopseong 2-gil, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Republic 
of Korea 
TEL: +82-41-523-8993 
 
Please contact your dealer for service. 
 
 
 
 

 

 

 

Содержание Confiscope g20

Страница 1: ...w Unless used for making a software copy for approved use in accordance with the copyright law no information contained in this User Manual may be reproduced in whole or in part without the prior writ...

Страница 2: ...GenBody Inc Page 2 28 APPENDIX EXPLANATION OF LABEL SYMBOLS...

Страница 3: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installatio...

Страница 4: ...ept any interference including interference that may cause undesired operation of the device Cet appareil contient des emetteurs recepteurs exempts de licence qui sont conformes aux RSS exempts de lic...

Страница 5: ...Use 1 4 Precautions during Use 1 5 Precautions for Storing and Managing the System after Use 2 Product Introduction 2 1 Intended Use 2 2 Principle of Analysis 2 3 Product Components 2 4 Parts Descript...

Страница 6: ...6 1 4 Battery Alarm 6 1 5 Incubation Alarm 6 1 6 Equipment Reset 6 1 7 Sleep Timer 6 2 Device Update 7 Cleaning 8 Trouble Shooting 9 Other Information 9 1 System Specification 9 2 System Characteristi...

Страница 7: ...manual 1 2 Precautions for Installation the Product 1 2 1 Do not install in an unsafe place 1 2 2 Do not install near inflammable objects or contaminated places 1 2 3 Do not install in areas where mo...

Страница 8: ...e level during analysis 1 4 3 When installing the testing cartridge into the tray make sure the cartridge is fully placed on the surface of the tray 1 4 4 Press the operating button after the tray is...

Страница 9: ...uffer solution to be tested into the cartridge open the tray insert it into the instrument and press the start button The instrument is testing during the reaction time and the optical module inside t...

Страница 10: ...Power Button h USB ports 2 0 A type use for administrator i Battery charging port micro USB j Forced power off switch 3 Installation and Start 3 1 Powering on the system Press the power button on the...

Страница 11: ...elete Settings General Settings Brightness Date Time Key Sound Battery Alarm Incubation Time Equipment Reset Sleep Timer Calibration Setup Device Update 3 2 Powering off the system Press the power but...

Страница 12: ...as shown below the information will be read and entered into the machine Products without RFID tags cannot be analyzed Please ensure that the RFID tag is attached to the product to be tested If RFID...

Страница 13: ...he RFID Tags screen At the Select Item screen navigate to the item to be inspected by using the upper and lower buttons and select it When the Select Lot screen appears you can replace RFID tags by mo...

Страница 14: ...pared samples and reagents are injected into the cartridge and the tray is closed immediately Press the analysis button if analysis does not start even when the tray is closed Do not open the tray unt...

Страница 15: ...is is not a valid result If the control band is not illuminated due to contamination damage to the product or sample Invalid status may appear and discard the cartridge and re examine it with a new ca...

Страница 16: ...sposal act 5 Data Management Select Data Management from the main menu to view and manage past examination results 5 1 Test Records If you have more than one exam history it is arranged in the latest...

Страница 17: ...has selected Data Management USB Backup from the main menu the following screen appears Connect the USB memory to the right side of the machine navigate to the time period for which user want to back...

Страница 18: ...ce Once you have selected Data Management delete from the main menu the following screen appears navigate to the time period you want to delete and press the Select button Deleted data cannot be retri...

Страница 19: ...Time Key Sound Battery Alarm Incubation Alarm Equipment Reset Sleep Timer Calibration Setup Calibration Setup Device Update Serial Number of device and version check Update 6 1 General Setup User can...

Страница 20: ...want to change Press the Up Down button to adjust the current date and time and press the Select button to temporarily save the changes Press and hold the select button to return to the General Setup...

Страница 21: ...ttery Alarm By entering to Battery Alarm setting user can adjust the strength of the low battery sounds effect by using the up down buttons Press and hold the Select button to return to the General Se...

Страница 22: ...he reset with the kit s RFID tag secured The data cannot restore once the initialization has been made Press and hold the power button for 2 to 3 seconds to turn the unit back on after initializing is...

Страница 23: ...roceed the update If you want to update to the latest version download the file from PC and copy the downloaded file to the USB drive and connect the USB to the USB port located on the side of the dev...

Страница 24: ...user but calibration is only possible by the manufacturer and service center 8 Trouble shooting Problem Suggested Solution In the event of no power 1 If the battery is completely discharged charge for...

Страница 25: ...edded Firmware non OS Support Language English USB Port USB A 2 0 1 Port Micro USB 1 Port RFID Module 13 558Mhz for Reading Lot Information Tested temperature is from 20 to 50 Adaptor In Out Rating In...

Страница 26: ...each item Max 20 When 20 lot information data are saved 1st stored information is automatically deleted Capacity of measurement data Max 1000 test When 950 tests are saved backup warning is displayed...

Страница 27: ...GenBody Inc Page 27 28 10 3 Product Service GenBody Inc 3 18 Eopseong 2 gil Seobuk gu Cheonan si Chungcheongnam do Republic of Korea TEL 82 41 523 8993 Please contact your dealer for service...

Страница 28: ...GenBody Inc Page 28 28...

Отзывы: