background image

troubleshooting

If the led indicator does not light with a battery connected, or blinks the over-battery-voltage 
error, or the controller does not charge, the internal fuse may be blown.  Check the fuse inside 
the GVB by removing the four screws on the bottom of the enclosure.  If the fuse is blown, 
replace it with a 10a fast-acting ato or atC fuse rated for the maximum battery voltage.  
automotive-style fuses are typically rated to 32V, and are suitable for the GVB-8-Pb-12V, GVB-
8-Pb-24V, and lithium models with a CV voltage up to 31V (i.e., GVB-8-li-31.0V. For the GVB-8-
Pb-36V, gVb-8-Pb-48V, and higher-voltage lithium models, a fuse with a higher voltage rating 
is required. We recommend Littelfuse part number 142.6185.5102, rated to 58V.

LeD

 rUn/CHarGe InDICatIOn

Standby:

 

the battery is connected properly and ready to charge 

when solar panel power is available. 

2 SEC. BETWEEN BLINKS

Charging (low current, input current less than ~3.5A): 

FAST & SHORT BLINKS

Charging (high current, input current more than ~3.5A)

:

 

LONGER BLINKS

Charging (current limit): 

charging at current limit.

the GVB is overloaded and limiting input current.  Check that the 
solar panel rating is within the GVB’s input specifications. 

LONG, THEN SHORT BLINKS

Battery Charged:

 

the battery is in the absorption  

or float charging stage.

SOLID LED

LeD

 errOr InDICatIOn

Overheat: 

the controller’s internal temperature is too high.  

SETS OF 2 RED BLINKS.

Overload: 

the GVB has been overloaded.  

this could be caused by changing the solar panel connections 
while the controller is operating.  

SETS OF 3 RED BLINKS.

Battery voltage too low:

 the controller cannot begin charging 

due to low battery voltage.  Charge the battery by some other 
means before use. 

SETS OF 4 RED BLINKS

Battery voltage too high: 

Check that the correct GVB has been 

selected for the nominal system battery voltage.  If the nominal 
battery voltage is correct, check the functioning of other 
chargers that may be connected to the system. this error can 
also be caused by a disconnected battery or blown fuse.  

SETS OF 5 RED BLINKS.

Internal Error: 

Contact your dealer for assistance.  

2 LONG BLINKS, FOLLOWED BY ANY NUMBER  
OF SHORT BLINKS.

the GVB has a 

multI

ColoR

 led

Status Indication:

Specifications:

The most common causes of blown fuses are:

• Connecting the gVb to the battery backwards
• shorting the solar panel input while the gVb is 
charging. In this case, there may be other internal 
damage to the controller.

marine Grade:

Yes

Yes

Waterproof:

NO 

NO (See Genasun Model GVB-WP)

NO (See Genasun 

Model GVB-WP)

Connection:

4-position terminal block for 10-30AWG wire

Weight:

6.5oz., 185g

dimensions:

5.5x2.5x1.2”, 14x6.5x3.1cm

Warranty:

5 years

GVB-8-Pb-12V

GVB-8-Pb-24V

GVB-8-Pb-36V

GVB-8-Pb-48V

GVB-8-Li-**.*V

Отзывы: