background image

6

Installation

Free standing floor installation

Position the product vertically on an even base in close vicinity of the room fresh 
air ventilation. Ensure that the air inlets in the bottom sides or the clean air outlet 
on top of the product are not covered by other objects. Connect the power 
supply cord to a wall socket with Protective Earth (PE) connection.

For safety of use ensure in all installations that the AC power cable can be 
detached easily.

Do not install the product in wet locations, outdoors, or sheltered outdoor areas 
without temperature control.

Wall Installation 

Make sure the wall can handle the weight of the unit. Measure the distance 
between hanging holes. Install wall anchors and screws accordingly and place the 
unit on the screws. Also horizontal installation is possible. 

The product shall be used and stored indoors.

 ! 

Do not use the product in vicinity of concentrated flammable gases, liquids, or 

large amounts of dust. The product’s internal operation may ignite the concen-
trated gases or dust.

Do not use the product in rooms without fresh air ventilation.

!

 Connect the product with the AC power cord delivered with the product 

package.

Use only AC power cord rated 220-240 Vac and with ground (PE) connection.

   Wire diameter >1.5 mm2.

Do not position the product so that it is difficult to operate if disconnection is 

necessary.

The product shall not be used without legs when in free standing installation

Содержание Elixair E600

Страница 1: ...Elixair E600 AIR DECONTAMINATION UNIT Manual English...

Страница 2: ...tents E600 Contents of delivery Technical specifications Precautions Lifting and carrying Installation Operational use Maintenance Product storage End of life Instructions for Disposal 3 4 4 5 5 6 7 8...

Страница 3: ...various types of healthcare spaces and laboratories If you start the product for the first time it is recommended to use the highest fan speed for a short period then lower the speed for continuous u...

Страница 4: ...ons w x h x d 34 cm x 93 cm x 38 cm Weight 16 7 kg Class I electrical installation with Protective Earth PE in use Rated input voltage 220 240 Vac 10 fluctuations of mains voltage Protected against oc...

Страница 5: ...serviceable parts inside Only Service Personnel authorized by the manufac turer shall open the chassis mechanics for maintenance and service The product has maintainable parts inside For maintenance o...

Страница 6: ...he weight of the unit Measure the distance between hanging holes Install wall anchors and screws accordingly and place the unit on the screws Also horizontal installation is possible The product shall...

Страница 7: ...e appliance Picture 1 E600 knobs at the bottom Supply power inlet on off switch and fan speed control 1 Turn on the product after connecting AC power cord press the on off switch on bottom plate 2 Adj...

Страница 8: ...Hz Wipe the product clean with slightly wet cloth To avoid any damage on surface do not use strong detergents Air collector replacement Only Genano company authorized personnel may perform the mainten...

Страница 9: ...or cleaning the collector tube the product shall be dismantled for the cleaning Only Genano company authorized person nel may perform the maintenance operations For maintenance contact the local Genan...

Страница 10: ...ectronics base plate shall be recycled as aluminium Al parts 2 Collector tube shall be recycled as ferrous steel Fe 3 Electronic components and cables shall be recycled as electronic waste 4 Active ca...

Страница 11: ...11...

Страница 12: ...www genano com E600 UserManual EN revA ver1...

Отзывы: