GEN ENERGY G-B100 Скачать руководство пользователя страница 2

10

11

CHARGE

DISCHARGE

09

Quick Guide (V-mount Type) 

* Do not use the battery (Main, D-Tap, USB) while charging.

   If so, it may cause a charging error or damage the charger. 

* Charge the battery to full before first use.

* When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. 

* Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use.

* If you don’t use 20% bottom of capacity, its life time will become double. 

* Camera's low voltage alarm is recommended to set 13V.  

* Battery will stop at 11.4V to extend its life. (Reset it to re-use it by pushing and holding the gauge button for over 5 sec.)

* Microwave transmitters with 5W outputs or over should be kept as far away from the battery. 

  It may disrupt or stop supplying power. 

* Be sure to remove the battery from the device after use. 

  If so, it will consume large standby power and over-discharge protection may be activated. 

* USB is activated by pushing Battery capacity LED gauge button.

  USB power will turn off automatically 30 minute after no use. 

* Battery run time reduces when it is working below or above the recommended temperature range.

GEN ENERGY

Li-ion Battery

MADE IN KOREA

ISO 9001  ISO 14001

SAMSUNG cell inside

 

Make sure of + - Polarity of D-Tap prior to plug-in 

 

May explode when exposed to fire

 

Do not expose to extreme heat over 60ºC (140ºF) 

 

Do not short the battery terminals

 

Opening unit will void warranty 

 

Read instruction manual before use

 

Use recommended charger only

 

Keep dry and cool, best between 10ºC ~ 30ºC 

 

Avoid heavy impacts

 

Recharge the battery to full before first use

MADE IN KOREA

CAUTION

D-Tap 1

Charge : 16.8V 

Discharge : 12~16.8V  7A max.

 12A max.(15A, 22A, 26A models)

(sum of two D-Taps)

D-Tap 2

Charge : 16.8V

Discharge : 12~16.8V  7A max.        

                12A max.(15A, 22A, 26A models) 

                (sum of two D-Taps)

LED gauge button

  

5 LEDs 

  LED On : 20 % 

  Blinking : 10%

  Red blinking : to be charged (1% left)

  ※ 

Red On : Error (Push and hold this button for 5 second

s)=>Reset

  * While discharging, if you push it three times, blue LED light disappears, push it three times again, light's back. 

  * If you push it, it will make the battery pack activated again from sleep mode. 

     (Battery pack goes to sleep mode 48 hours after no use) 

Main connector

USB

Discharge : 5V, 2.3A max.

USB activated by pushing LED gauge button

(If no use for 30 min, it goes to sleep mode.)

CAUTION

Read throughly before use

V-mount lock

Do not short these two terminals

For more information

,

  http://www.genenergy.co.kr

GEN ENERGY

 

Make sure of         polarity

Plug side

(male connector)

Receptacle side

(female connector)

Plug side

(male connector)

Receptacle side

(female connector)

 

Make sure of        polarity

Charging : 16.8V 

Discharge : 12~16.8V  12A  (sum of main, D-Tap, USB), 

             15A (15A model), 22A (22A model), 26A (26A model)

             

Negative

Отзывы: