Gems RotorFlow RFS-2500 Series Скачать руководство пользователя страница 3

Switch Set Point Calibration with LED Signal 

With the unit  installed in the line and power supplied, complete the following steps to calibrate switch actuation point with 
proper flow rate. A small flat-blade screwdriver is all that is required. 

 

1.  Adjust liquid flow in the line to the 

rate at which actuation is desired. 

2.  Insert screwdriver into opening on 

backside of housing and fit blade  into 
the potentiometer adjustment screw 
inside. 

3.  If LED is not illuminated, slowly turn 

screwdriver counter-clockwise and 
stop as soon as LED illuminates. 

4.  If LED is illuminated, turn screwdriver 

clockwise until LED light goes out. 
Then, slowly turn screwdriver 
counter-clockwise and stop as soon 
as LED illuminates. 

Specifications 

† Hydrolytically stable, glass-reinforced, Polypropylene is UL-recognized to UL746B at a 

relative temperature index of 65°C 

Wetted Materials  
  Body

 

Brass, 316 SS or Polypropylene, Hydrolytically Stable, Glass-Reinforced

 

  Rotor Pin

 

Ceramic

 

  Rotor

 

PPS Composite/Teflon/PPS Composite

 

  Lens

 

Polysulfone

 

 O-Ring

 

Buna N/Viton

 

Operating Pressure, Max. Brass            

  Body & 316 SS Body

 

200 PSIG @ 70°F 

80 PSIG @ 212°F

 

100 PSIG @ 70°F 

40 PSIG @ 212°F

 

212°F (100°C)

 

  Polypropylene Body

 

180°F (82.2°C)

 

  316 SS Body

 

212°F (100°C)

 

Electronics (All Bodies)

 

150°F (65.5°C)

 

Viscosity, Max.

 

200 SSU

 

Input Power

 

12 VDC, 24 VDC or 110 VAC

 

Relay Contact Ratings (SPDT)

 

1 Amp, 24 VDC Resistive 0.3 Amp, 110 VAC

 

Repeatability

 

2% Maximum Deviation

 

Set Point Accuracy (Factory Set)

 

±5%

 

Set Point Differential

 

15% Maximum

 

Electrical Termination

 

22 AWG PVC-

Jacketed, 24" Cable. Color codes: Red = +VAC/VDC;

 

Black = Ground; White = N.O. Contact; Brown = N.C. Contact; Green = Common.

 

 Polypropylene Body  

 
Operating Temperature, Max.    
  Brass Body

 

Содержание RotorFlow RFS-2500 Series

Страница 1: ...in the port selected for incoming flow See Flow Range Chart below With use of low flow adapter supplied Straight thread with O ring seal Standard Low Flow Body Material Port Size NPT Input Power Part Number Range Range Adapter Part Number Polypropylene 25 12 VDC 155424 0 5 5 0 0 1 1 0 152147 24 VDC 155425 110 VAC 155876 50 12 VDC 155484 4 0 20 0 1 5 12 0 151832 24 VDC 155485 110 VAC 155886 Brass 2...

Страница 2: ...g the lens from the body The lens is removed by turning its center rib 45 C counter clockwise and then pulling it out To reinstall the lens simply reverse the process Pressure must be relieved from the system prior to sensor clean out Panel Mounting Any RotorFlow sensor may be panel mounted using holes integrated into the bodies Plastic Bodies Two 2 mounting ears are provided at the body centerlin...

Страница 3: ...ically stable glass reinforced Polypropylene is UL recognized to UL746B at a relative temperature index of 65 C Wetted Materials Body Brass 316 SS or Polypropylene Hydrolytically Stable Glass Reinforced Rotor Pin Ceramic Rotor PPS Composite Teflon PPS Composite Lens Polysulfone O Ring Buna N Viton Operating Pressure Max Brass Body 316 SS Body 200 PSIG 70 F 80 PSIG 212 F 100 PSIG 70 F 40 PSIG 212 F...

Страница 4: ...atalog and instruction bulletin Failure to observe this warning could result in serious injuries or damages Pressure and temperature limitations shown on individual catalog pages and drawings for the specified flow switches must not be exceeded These pressures and temperatures take into consideration possible system surge pressures temperatures and their frequencies Selection of materials for comp...

Отзывы: