PROGRAMMING PARAMETERS
Note: If no entry is done for 20 sec. during programming, current entries are accepted and saved to
EEPROM memory.
Gürbüzo
ğ
lu Elektronik San. ve Tic. Ltd.
Ş
ti.
http://www.gemo.com.tr
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
e-posta: [email protected]
Tel: +90-312-3503900, Fax: +90-312-3511117
4
Press for 2 sec.
SET
SET
Prog. end
Upper Display
Out
000.0 .. 999.9
SET
SET
Out ON duration
For latching enter, 0.000
CALb
0.000 .. 9.999
SET
SET
Calibration constant
InPt
1u.2n,
1u.2u,
1u.2G,
1u.2d,
Phs.4,
Phs.1,
Phs.2
SET
SET
Input options
ConF
0..8
SET
SET
Operating modes
options
dEC.P
0, 0.0,
0.00, 0.000
SET
SET
Select place of
decimal point
Cr.dr
drCt, oPPo
SET
SET
Counting direction;
direct / opposite or
up / down
Freq
20, 500,
2500, 7500 Hz
SET
SET
Max. frequncy for input signal.
Select 20Hz for mechanical switch.
Pon.r
YES, no
SET
SET
Yes: Reset after power-on.
No: Loads the count value &
Output status at the latest power failure
after the first power-on.
+
CodE
Enter 162
SET
SET
Enter fixed password; 162
oFFS
0000 .. 9999
SET
SET
Offset Value;
1. If Cr.dr=drCt; Counter is set to
“oFFS” with RESET ON or panel reset.
2. If Cr.dr=oPPo; when Conf=0..6 and
Inpt= 1u.2u, 1u.2G, Phs.4,
OUT is ON, as soon as counter reaches
“oFFS”. (*)
(*) Decimal appears at
dEC.Pnt selection.
Factory SET Values:
PSt: 0100
Out: 001.0 sec.
CALb: 1.000
InPt: 1u.2n
ConF: 0
dEC.P: 0
Cr.dr: drCt
Freq: 20
Pon.r: YES
oFFS: 0000