INTRODUCTION

 

The  GEN-PACK  H-W™  is  a  half  wave  regenerative  SCR  drive  for  intermittent  operation  of  permanent  magnet  motors  in  a 
single  or  bi-directional  mode.    It  provides  forward  and  reverse  torque  in  both  directions,  maintains  constant  speed  with 
overhauling loads and provides rapid deceleration, reversing, and controlled regenerative braking.   
Feedback  is  jumper  selectable  from  either  armature  voltage  or  from  a  DC  tachometer  generator  with  fast  response  in  both 
feedback modes. 
 
 

Specifications: 

 

 

Speed Range: 50:1 

 

Overload Capacity: 150% for 60 seconds 

 

Maximum Speed Adjustment: 50-110% 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

    Output Amps 

 

     Model            Mounting 

  Input Voltage 

Output V. Range   

HP 

 

     Cont.  Max. 

 

12M6-42000  

Open chassis 

115/230 VAC 

 0 to 90/180VDC     1@115VAC, 2@230V         10      20 

 

12M6-42001 

NEMA 12 Encl.  115/230  

 0 to 90/180 

    1@115VAC, 2@230V         10      20 

 

 

 

 

GENERAL

 

These instructions provide basic information for installation and adjustment.  Please contact Gemini Corp. if further information 
is necessary.  It is possible to damage the drive through misuse or misapplication.  Please read this material thoroughly before 
proceeding with installation.  
Unpack  the  equipment  noting  any  shortages  or  damaged  equipment.    Immediately  notify  the  carrier  of  any  damage.    Store  in 
clean, dry location if the product is not used immediately.  The relative humidity should not exceed 95%, non-condensing. 

 

Caution:  This control provides half wave rectified power to the DC motor.  Peak currents result in an RMS equivalent 
current that may be considerably higher than with a full wave source of power.  For this reason it may be necessary to 
derate the motor to avoid overheating.  Consult with the motor manufacturer and Gemini for specific information. 

 
INSTALLATION 

Carefully mount the chassis or enclosure  allowing clearances for access, air flow and conduit entry.  The environment should be 
free of vibration and contaminants.  The operating temperature range for the Gemini drive is 32 to 104 degrees Fahrenheit (0-
40C).  Since the drive produces heat, utilize a source of cooling, such as a fan, when the ambient temperature approaches 104 
degrees. 
 

WARNING: 

Do not drill or file the enclosure or chassis when the controller is installed, as metal       

 

           

 

            particles can cause shorts and  damage. 

 

WIRING

 

 
1. Input Wiring  
a.  Since  the  control  will  operate  on  either  115  or  230VAC,  jumper(s)  must  be  applied  to  obtain  the  required  voltage.    For 
115VAC input, place a jumper between terminals “H1” and “H3”, and another jumper between terminals “H2” and “H4”.  For 
230VAC  input,  place  a  jumper  between  “H3”  and  “H2”.    Connect  the  AC  line  to  terminals  “L1”  and  “L2”  (note  wiring 
diagram).   Terminals “S1” and “S2” are used as wiring points when a line switch is used for ON-OFF control.  Wire one pole of 
a two pole switch to connect between terminals “L1” and “S2”.  Wire the other pole to connect “L2” and “S2”. 
 
 If required, the chassis may be grounded at one of the unused holes.  Input wire size must be in compliance with the National 
Electrical Code and all local codes and restrictions. 

 

WARNING

:

 Do not connect line power to the motor terminal connections. 

b. Note the jumper terminals on the top circuit board.  Install a small shunt type jumper at position “K” for a 115VAC input and 

 

 

4 Quadrant SCR GEN-PACK H-W DC Drive

 

Instructions

 

Models 12M6-42000 and 12M6-42001 

Содержание GEN-PACK H-W 12M6-42000

Страница 1: ...f power For this reason it may be necessary to derate the motor to avoid overheating Consult with the motor manufacturer and Gemini for specific information INSTALLATION Carefully mount the chassis or enclosure allowing clearances for access air flow and conduit entry The environment should be free of vibration and contaminants The operating temperature range for the Gemini drive is 32 to 104 degr...

Страница 2: ...e system with a 5K potentiometer as a speed reference Connect the external source only after satisfactory operation with a potentiometer as any problem may then be directed toward interfacing The frequency of a pulse width modulated input signal must exceed 50Hz otherwise damage may result An external signal of 0 to positive 6VDC is used for forward motion A zero to 6VDC signal is required for rev...

Страница 3: ...he motor runs away in the desired direction remove power and reverse the polarity of the tach leads b If the drive runs in the wrong direction remove power and reverse the polarity of the armature leads c If the drive runs at a low controlled speed but in the wrong direction remove power and reverse the polarity of both the armature and tach leads d If the drive runs at controlled low speed in the...

Страница 4: ...t limit pot CL clockwise approximately 25 30 The motor should not be rotating 5 Turn the deadband pot DEAD B clockwise until a slight buzzing is heard 6 Reconnect the speed pot or external signal and set the current limit pot CL to approximately 50 7 Increase speed and observe motor direction Remove power and reverse the motor leads if incorrect 8 While varying the signal up and down adjust the st...

Отзывы: