X
GEM-P1664 Installation Instructions
L
NAPCO Security Systems
WI1424A 1/06
Page 52
Ke
yp
ad
Programming Mode
s:
Ke
yp
a
d
Configur
ati
o
n Mode
KEYPAD CONFIGURATION MODE
GEM-RP1CA/1CAe/1CAe2/
GEM-K1CA KEYPADS
Press
R
(or
A
) button
Enter Factory Code:
11123
Configure:
•
Keypad Beep ON/OFF
•
Entry Sounder
•
Keypad Address 01
•
New Compat# 000 **
Press
C
button
(“
01 OUT OF SYSTEM
”)
Return Jumper JP1 * from Pins 2-3 to Pins 1-2
(“
SYSTEM READY
”)
Move Jumper JP1 * from Pins 1-2 to Pins 2-3
(Wait about 15 seconds: “
OUT OF SYSTEM
”)
Configure:
•
Keypad Address (Jumpers J1-J3)
•
Touchpad Backlight (Jumper A)
•
LCD Backlight (Jumper B)
GEM-RP2AS/RP2ASe/RP2ASe2
KEYPADS
* JP1 is located at the top center of the circuit board.
** Not available in the GEM-P1664.
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
For "Classic" Keypads
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
R