background image

v0.9 | 16  

 

 

Questions? Feedback? Please contact 

Michael Thot

 or assign him a Task using 

this template

 

 

 

↪ 

You can download adb tooling 

here

.  

On Windows version 29.0.5 works. Version 30.0.4 gives 

this 

error. 

Drivers 

 You will also have to download Qualcomm’s drivers to interface with the device.  
 

↪ 

Qualcomm drivers can be downloaded 

here

.  

 
If your computer is running Windows, you will also need to download Oculus ADB Drivers. 
 

↪ 

Oculus ADB drivers can be downloaded 

here

.  

Connecting to a Computer 

Connection order matters, as your device may not be recognized if the magnetic end is 
connected last.  
 
First, connect the magnetic end of the USB cable to your device. Then, connect the USB end to 
your computer. The device should be recognized within seconds by your computer if everything 
is working correctly.  
 

If you are having issues with your computer recognizing the device, ensure

 

you are connecting 

the magnetic device end of the cable first! 

Verifying and Viewing Recordings 

The Companion App does not have playback capabilities.  
 
In order to view your recordings, you’ll need to pull them off the device onto a computer with adb. 
Then, we’ll use 

VRSPlayer

 to view the recording. 

Copying Recording Files 

1.  Connect your device to your computer. 
2.  Pull the VRS file from your device to your computer:  

a. 

$ adb pull /data/test.vrs

 

3.  Pull the metadata file associated with your recording:  

a. 

$ adb pull /data/test.vrs.json

 

Содержание EVT

Страница 1: ...Gemini User Guide...

Страница 2: ...Michael Thot Adding section for boot instructions QFIL Flashboot 0 6 25 February 2020 Michael Thot Split Gemini Client content to separate doc Revised based on suggestions comments from Renzo 0 61 2...

Страница 3: ...accompanying the Glasses before using them Follow all instructions and alerts provided through the companion app Vision Prescription lenses If your glasses have prescription lenses they are intended...

Страница 4: ...Distraction Do not allow use of the Glasses to distract you from your surroundings Charging electrical heat Charging Use only the provided charging cable and power adapter to charge your Glasses Keep...

Страница 5: ...a break If discomfort persists stop using and consult a medical professional Skin sensitivity If you have skin sensitivities be careful before and while wearing the Glasses Keep the Glasses clean and...

Страница 6: ...v0 9 5 Questions Feedback Please contact Michael Thot or assign him a Task using this template...

Страница 7: ...er Safety Officer John Flores McLaughlin or EHS if there are any suspected injuries or if you have questions about eye safety Conditions of Use The Gemini EVT headset is only to be used by FTEs and co...

Страница 8: ...v0 9 7 Questions Feedback Please contact Michael Thot or assign him a Task using this template...

Страница 9: ...act Michael Thot or assign him a Task using this template Switches Buttons The device has 3 physical points of interaction a toggle switch and 2 buttons Mute Switch Toggles privacy mode on off Privacy...

Страница 10: ...will exit this state and turn on within 30 seconds 2 minutes Some have been observed taking as long as 15 minutes Please be patient if your device is taking longer than normal it may turn on later th...

Страница 11: ...is advised that you connect the magnetic device end of the USB cable before connecting the other end to your computer See USB Is Connected But Device Does Not Enumerate for more details The Companion...

Страница 12: ...gn him a Task using this template Make sure your device is powered on and tap the Add Device button and the app will begin to look for nearby Gemini devices The app will display a list of devices foun...

Страница 13: ...ign him a Task using this template The app will then prompt you to join a WiFi network and input the associated password After connecting to WiFi the app will return to its home page and display devic...

Страница 14: ...LED Low Battery Flashing red LED 5 seconds on 5 seconds off Recovery Mode Alternating blue and red may appear as violet because the LEDs alternate very quickly Offline Crash Mode Off Powering On Green...

Страница 15: ...connector to the device Then plug the USB end into your computer The magnetic USB connection is known to be somewhat flaky on the EVT model If the magnetic connector attaches from front to back it wi...

Страница 16: ...ered to it Help Improve This User Guide If you believe something needs to be addressed immediately you can also assign a Task to Michael Thot through this Task template Appendix Useful Links Recording...

Страница 17: ...the magnetic end of the USB cable to your device Then connect the USB end to your computer The device should be recognized within seconds by your computer if everything is working correctly If you ar...

Страница 18: ...h mac or win for other systems If you don t not have a clone of ovrsource You can download pre built binaries from this folder Once you have the tool built or downloaded simply 1 Run VRSPlayer exe to...

Страница 19: ...ce USB VID_18D1 PID_D00D REV_0100 Diagnostics Qualcomm HS USB Diagnostics 900E USB VID_05C6 PID_900E REV_0000 Windows On a Windows system you can use the Device Manager tool to display the device s ha...

Страница 20: ...urn blue when the device is sufficiently charged Backup Persist Partition Currently the QFIL process will delete the persist partition on the device This will create MAC address inconsistencies Before...

Страница 21: ...his template Update Process QFIL Download 1 Once charged unplug the device from the USB cable Then turn it off by pressing the capture button for 5 seconds 2 Go to gemini com arianestu and download th...

Страница 22: ...mputer almost immediately g The QFIL program should not display that it s connected to a Qualcomm HS USB QDLoader 9008 device This confirms that your device has successfully been placed in QDL mode 5...

Страница 23: ...ool as Gemini under Universal Serial Bus devices and the power LED should be blue i If the device does not enumerate as Gemini press the capture button for 5 second This should reboot the device and p...

Страница 24: ...n the command python flash_all py to flash the OS build to your device FCC Regulations This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This de...

Страница 25: ...his device is set to transmit at its highest certified power level in all tested frequency bands and placed in positions that simulate RF exposure in usage near the body Although the SAR is determined...

Отзывы: