A user friendly PC software allows more flexibility in programming the parameters. The dedicated interface also allows reading and overwriting previously configured 

parameters. Please contact us for more information. 
 
 
 
 
 
 
 
 
 

 

Programming can be done using the 2 buttons on the buzzer or via a user-friendly PC software. 

 

 

Programmable parameters 

Button 

Button 

Settings 

Default 

settings 

Buttons & PC  Only PC* 

Sensitivity 1 

 

 

 

Low 

 

Medium 

 

 

 

Medium 

 

 

 

High 

 

 

Buzzer volume 

 

 

 

 

Low 

 

High 

 

 

 

High 

 

STOP zone => Inner Sensors 

 

 

 

 

 

30 cm 

 

35 cm 

50 cm 

 

 

40 cm 

 

45 cm 

 

 

50 cm 

 

 

MAXIMUM distance => Inner Sensors 

 

 

 

50 cm 

55 cm

 

80 cm 

 

 

60 cm 

65 cm

 

 

 

70 cm 

 

 

80 cm 

 

 

 

100 cm 

STOP zone => Outer Sensors 

 

 
 

30 cm 

 

35 cm 

40 cm 

 
 

40 cm 

 

45 cm 

 

 

50 cm 

 

 

MAXIMUM distance => Outer Sensors 

 

 
 

50 cm 

 

55 cm 

70 cm 

 
 

 
 

60 cm 

 

65 cm 

 
 

 
 

70 cm 

 

 

 

80 cm 

 

 

 

100 cm 

Deactivation delay 

(Maneuvering time period expired) 

 

 

 

Never 

 

30 sec. 

 

 

30 sec. 

 

 

 

60 sec. 

 

ON/OFF via odometer

 

 5 

 

 

 

Automatic 

 

 

Automatic 

 

 

 

OFF 1 time 

 

Odometer  

Number of speed signal pulses/m  

 

 

 

 

3 pulses/m 

 

9 pulses/m

 

6  pulses/m 

 

9  pulses/m 

 

15  pulses/m 

 

21  pulses/m 

 

30  pulses/m 

 

Automatic speed reading 

 

 

 

 

 

 

 

 

12.0 - PARAMETER CONFIGURATION TABLE 

 

Содержание 514F

Страница 1: ...beings animals or small obstacles or objects materials with low reflectance might not be detected by the parking system 2 In case of heavy rain snow the parking system might give an audible alert eve...

Страница 2: ...de tabs from the top side 3 The sensors must be inserted in the slots from underneath the cardboard For a perfect spray paint finish we recommend turning down the black silicone seal around the sensor...

Страница 3: ...ensor 4 Finish the holes to the proper diameter using a cone drill bit that matches the diameter of the selected adapters Determine the correct mounting height and position to achieve the best detecti...

Страница 4: ...bumper shape Standard 18mm hole Angled 10 20mm hole to correct the angle of the sensor heads on bumpers that curve up or down 3 Peel off the adhesive film on one side of the pad and apply on the front...

Страница 5: ...e vehicle reaches the set speed configuration 59 In this case the system can only be reactivated via the manual switch 3 BROWN wire by connecting this wire to the radio MUTE volume is temporarily excl...

Страница 6: ...cessfully programmed the buzzer will give off a Jingle Proceed with another setup 2 In case of an incorrect entry a low tone signal Bop will sound Re enter the desired code Turn ignition OFF and then...

Страница 7: ...ult settings Buttons PC Only PC Sensitivity 1 1 Low Medium 2 Medium 3 High Buzzer volume 1 7 Low High 8 High STOP zone Inner Sensors 2 1 30 cm 35 cm 50 cm 2 40 cm 45 cm 3 50 cm MAXIMUM distance Inner...

Страница 8: ...rking system Correct Position height inclination and orientation are correct Sensors fitted too low false alarms due to ground detection Sensors are excessively turned upwards low obstacles are not de...

Страница 9: ...odify setting Sensitivity might be too high Adjust sensitivity Check that there is no excessive paint on the sensor surface Too much spray paint can impair sensor ability to function properly No warni...

Отзывы: