Appendix B: Specifications
General Specifications
Displacement
2" to 100" (50mm to 2540mm) in .1" or 5mm increments
Performance Specifications - Measurement
Linearity
+/-0.04% of Span or +/-0.008", whichever is greater
Hysteresis
0.001" maximum
Repeatability
Equal to Resolution of output signal, +/-0.01% of Span or 0.001", whichever is
greater
Update Time
0.5 ms minimum, proportional to length of LDT - not to exceed 4ms
Null & Dead Bands
Null
1.18" (30mm) from flat face of LDT housing
Dead
2.49" (63.25mm) from end of rod
Mechanical Specifications - Housing
Material - Housing
Stainless Steel 1.4305 / AISI 303
Diameter
1.89" (48mm)
Length (width)
1.31" (33.3mm)
Guide Tube Material
Stainless Steel 1.4404 / AISI 316/316L
Diameter - Guide Tube
8mm & 10mm (10.29mm actual)
Guide Tube Pressure
Continuous
10mm - 5,076 PSI (350 bar)
8mm - 4,351 PSI (300 bar)
Spike
10mm - 10,000 PSI (689 bar)
8mm - 5,801 PSI (400 bar)
Housing (O-ring)
5,076 PSI (350 bar)
Temperature
Head - Electronics
-40°C to + 85°C
Guide Tube
-40°C to + 105°C
Storage
-40°C to + 105°C
Shock & Vibration
Shock
1,000 G’s, single hit (per IEC 60068-2-27)
Vibration
30 G’s, 10Hz - 2kHz (per IEC 60068-2-6)
Ingress Protection
Protection level
IP68 (per EN 60529)
Electrical Specifications
Power Consumption
1.6 Watt maximum (50mA @ 24VDC typical)
Input Voltage