3.2.
Setting Menu
The setting menu is an interface with the setting pages and
parameters of the device. It allows the device to operate at an
optimum level with the changes and adjustments made. The device is
switched off to enter the setup menu. An image like the one will
be displayed on the LCD screen. The
MENU
button is kept
pressed for 3 seconds while the device is in the OFF position. The
device will automatically switch to the setting menu.
Setting menu contents are shown in the table on the right. In
the table, the setting pages and the parameters in the pages are
indicated.
3.2.1.
POLARITE PERIOD
Although the physical properties of the water used vary depending on geographical regions, it inevitably
contains certain amounts of calcium, magnesium, iron, and other minerals. While the water is cold, these
suspended minerals dissociate from the water during electrolysis, some of them stick to the electrodes in the
chamber. After a certain period, the electrodes are completely covered with the substance called lime. Since the
lime layer is insulating, it complicates the flow of electricity between the electrodes. As a result, chlorine
production efficiency decreases. This lime formed in the electrodes must be cleaned periodically.
This cleaning process; It has the feature to do it automatically by
changing the polarization. Polarity period page is the page where the
polarization change time is set. The OK button is pressed once to
enter the page, and to exit the page, the MENU button must be
pressed once. When entering the setting page, the parameter value is
changed with UP and DOWN direction buttons. When the desired
value is given, it is selected and saved with the OK button.
3.2.2.LANGUAGE
It is the page where the working language of the device is set.
There are English - TURKISH - FRENCH - BULGAR - GERMAN -
HUNGARY - SPANISH languages defined on the device. The OK button
is pressed once to enter the page, and to exit the page, the MENU
button must be pressed once. The working language is changed with
UP and DOWN direction buttons. When the desired working language
is displayed, the OK button is pressed once and the working language
is selected and saved.
Settings
1 - POLARITY PERIOD
POLARMA HOUR
2 - LANGUAGE
ENGLISH
TURKISH
FRENCH
BULGARIAN
GERMAN
HUNGARIAN
SPANISH
3 - PH SETTINGS
PH MOD
PH SET
PH TOL.
PH BUF. SEC
PH CALIBRATION
READ PH
PH LVL. SEC
4 - ORP SETTINGS
ORP MOD
ORP SET
ORP TOL.
ORP CALIBRATION
READ ORP
5 - PROGRAM MENU
PASSWORD