It is recommended to periodically check the cell terminals and lubricate against sulfurization. Situations
where you need to turn off the equipment:
•
Working without water
•
While cleaning the filter
•
When emptying the pool
•
When the water freezes
•
While cleaning the cell
4.3 - Fault Codes and Suggested Solutions
Fault Code
Possible Failure
Solution Way
E1
Cable is broken or not touching Check cable and connection
terminals, replace if
necessary.
Electrode wiring problem
Check electrode cable
connection terminals.
Heavy lime
Clean the lime from the cell
and reduce the polarity
period.
E2
There is lime
Clean the lime from the cell
and reduce the polarity
period.
The water is too hard
Soften the water.
E3
Device output has a short
circuit
Check device electrode cable,
electrode connection
terminals, and replace it if
necessary.
E4
Electronic card failure
Üretici ile iletişime geçin.
E5
Water Level warning
Check the water level in the
electrode chamber
E6
Electronic card high-
temperature warning
Contact the manufacturer.
E7
High water temperature
warning
Contact the manufacturer.
Lo
Low salt level warning
Salt must be added to the
pool.
5
–
WARRANTY - AFTER-SALES SERVICE - SPARE PARTS
1.
The electronic cell and rectifier are under a two-year warranty.
2.
The products are taken out of the scope of warranty in line with the items below.
a)
Malfunctions caused by using the product contrary to the operating instructions.
b)
Malfunctions due to incorrect electrical connections.
c)
Faults caused by crash and similar accidents.
d)
Malfunctions that will arise from water in its rectifier.
e)
Faults resulting from operation without a bypass circuit (according to the wiring diagram).
f)
Malfunctions caused by acid spillage into the skimmer without turning off the rectifier.
g)
Malfunctions caused by insufficient air circulation in the engine room where the acid tank used for
disinfection is located.
h)
Puritron; It must not be in the same environment with cleaning equipment, including pumps, filters,
and multi-way valves.