![Gemalto Cinterion ENS22-E Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/gemalto/cinterion-ens22-e/cinterion-ens22-e_at-command-set_2206709091.webp)
Cinterion
®
ENS22-E AT Command Set
6.11 AT+CIPCA
ENS22-E_ATC_V01.000
19/02/11
Page 91 of 189
6.11
AT+CIPCA Initial PDP context activation
controls whether an initial PDP context shall be established automatically following an attach proce-
dure when the UE is attached to GERAN or UTRAN RATs, and whether the UE is attached to E-UTRAN with or
without a PDN connection.
The
test command returns values supported as a compound value.
The
read command returns the current setting of the command.
The
write command controls whether the UE is attached to E-UTRAN with or without a PDN connec-
tion.
Syntax
Parameter Description
Activation of PDP context upon attach.
3
No change in current setting.
EPS Attach with or without PDN connection.
[0]
EPS Attach with PDN connection.
1
EPS Attach without PDN connection.
Test Command
AT+CIPCA=?
Response(s)
+CIPCA:
(list of supported
s)
OK
Read Command
AT+CIPCA?
Response(s)
[
+CIPCA:
]
OK
ERROR
+CME ERROR:
<err>
Write Command
AT+CIPCA=
[,
Response(s)
OK
ERROR
+CME ERROR:
<err>
PIN Last
Reference(s)
-
-
3GPP TS 27.007
<n>
(num)
<AttachWithoutPDN>
(num)(NV)