![Gemalto Cinterion ENS22-E Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/gemalto/cinterion-ens22-e/cinterion-ens22-e_at-command-set_2206709073.webp)
Cinterion
®
ENS22-E AT Command Set
6.3 AT+CESQ
ENS22-E_ATC_V01.000
19/02/11
Page 73 of 189
6.3
AT+CESQ Extended Signal Quality
The
command returns received signal quality parameters. If the current serving cell is not a GERAN
cell,
are set to value 99. If the current serving cell is not a UTRA FDD or UTRA TDD cell,
is set to 255. If the current serving cell is not a UTRA FDD cell,
is set to 255. If the current serv-
ing cell is not an E-UTRA cell,
and
are set to 255.
Syntax
Parameter Description
Received signal strength level (see 3GPP TS 45.008
subclause 8.1.4). For 2G networks only
99
not known or not detectable
Channel bit error rate (in percent). For 2G networks only
99
not known or not detectable
Received signal code power (see 3GPP TS 25.133
subclauses 9.1.1.3 and 9.1.1.1.3) For 3G networks only
255
not known or not detectable
Ratio of the received energy per PN chip to the total received power spectral density (see 3GPP TS 25.133
subclause 9.1.2.3) For 3G networks only
255
not known or not detectable
Reference signal received quality (see 3GPP TS 36.133
subclause 9.1.7). For 4G networks only
0
rsrq < -19.5 dB
1
-19.5 dB
≤
rsrq < -19 dB
2
-19 dB
≤
rsrq < -18.5 dB
Test Command
AT+CESQ=?
Response(s)
+CESQ:
(list of supported
s), (list of supported
s), (list of
supported
s), (list of supported
OK
Exec Command
AT+CESQ
Response(s)
+CESQ:
,
,
OK
ERROR
PIN Last
Reference(s)
+
-
3GPP TS 27.007
<rxlev>
(num)
<ber>
(num)
<rscp>
(num)
<ecno>
(num)
<rsrq>
(num)