![Gemalto Cinterion ENS22-E Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/gemalto/cinterion-ens22-e/cinterion-ens22-e_at-command-set_2206709069.webp)
Cinterion
®
ENS22-E AT Command Set
5.3 AT+CPWD
ENS22-E_ATC_V01.000
19/02/11
Page 69 of 189
5.3
AT+CPWD Change Password
allows to define a new password for a password protected
lock function. Each password
is a string of digits, the length of which varies with the associated
. The test command returns a list
of pairs which represent the available facilities and the maximum length of the associated password. See
for more information on the various lock features.
Syntax
Parameter Description
“SC“
SIM PIN. (U)SIM requests password upon ME power-up and when this lock
command is issued.
If incorrectly entered three times, the SIM PUK is required to perform authen-
tication. Input of the SIM PUK password is possible only with AT command
.
: 4 to 8 digits.
4...8
Length of password. The range of permitted length for a password depends on
. It is available from the test command response,
or in the description of parameter
.
Password specified for the facility.
New password.
Test Command
AT+CPWD=?
Response(s)
+CPWD:
list of supported (
)
OK
Write Command
AT+CPWD=
Response(s)
New password has been registered for the facility lock function.
OK
If parameter
was not correct:
+CME ERROR: 16 (+CME ERROR: incorrect password)
If the password for the selected
has been invalidated due to too many failed attempts:
+CME ERROR: ...
If error is related to ME functionality:
+CME ERROR:
<err>
PIN Last
Reference(s)
+
-
3GPP TS 27.007
<facility>
(str)
<password length>
(num)
<old password>
(str)
<new password>