Cinterion
®
EHS6 AT Command Set
2.6 ATX
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 37 of 513
2.6
ATX CONNECT Result Code Format
determines whether or not the EHS6 transmits particular result codes to the TE. It also controls whether or
not the ME verifies the presence of a dial tone when it begins dialing, and if engaged tone (busy signal) detection
is enabled.
Syntax
Parameter Description
[0]
CONNECT result code only returned. Dial tone and busy detection are dis-
abled.
1
result code only returned. Dial tone and busy detection are
both disabled.
2
result code returned. Dial tone detection is enabled, busy
detection is disabled.
3
result code returned. Dial tone detection is disabled, busy
detection is enabled.
4
(&F)
CONNECT
result code returned. Dial tone and busy detection are
both enabled.
Exec Command
ATX
]
Response(s)
OK
ERROR
PIN
Last
Reference(s)
-
+
-
V.250
<value>
(num)(&V)(&W)