V
02/18
OptiStar CG08(-C)
Initial start-up
•
37
Cleaning mode
The cleaning mode enables blowing off powder accumulations in the
powder hose with preset air pressure. This function is a two steps
process to activate.
The powder hose cleaning mode can be activated also by an optional
bus connection such as CAN bus.
NOTE:
The injector must be disconnected prior to cleaning procedure!
Activating the cleaning function
The cleaning mode can only be activated from standby mode (main
menu display, no powder conveying). The prerequisite is, that all
necessary release signals are present.
1.
2. Select the cleaning function
Key
Cleaning function
Powder hose cleaning with increasing air
volume
Powder hose cleaning with constant air
volume
The symbol S15 or S16 of the selected function is displayed
in blue
3. During the mode „Powder hose cleaning with increasing air
volume“ all airflows are increased step by step after starting
the cleaning procedure, and then they remain at the
maximum:
Time
[s]
0
1
2
3
4...
Conveying air
[Nm³/h]
0
2
4
5.5
5.5
Supplementary air
[Nm³/h] 0 1.5 3.0 4.5 4.5
Electrode rinsing air
[Nm³/h] 0 1.0 2.0 3.0 3.0
4. During the mode „Powder hose cleaning with constant air
volume“, there is no airflows increasing step by step. The
maximum values are set immediately.
The cleaning mode is exited: