www.gemu-group.com
18 / 37
GEMÜ SUPM
9 Installation in piping
5
A
4
3
Fig. 2: Assembling the pneumatic stainless steel actuator in the
housing
3. Guide the stainless steel actuator
A
through the recess of
the housing
5
from below. The mounting plate
4
of the
pneumatic stainless steel actuator
A
must lie flush on the
housing
5
.
4. Connect the mounting plate
4
and housing
5
using suit-
able bolts and washers (not included in the scope of deliv-
ery).
5. Connect the control medium line and, if necessary, attach
accessories to the pneumatic stainless steel actuator
A
.
9.3 Disassembling the pneumatic stainless steel
actuator – housing
5
A
4
3
Fig. 3: Disassembling the pneumatic stainless steel actuator –
housing
1. Depressurize the pneumatic stainless steel actuator
A
.
2. Remove the single-use diaphragm valve body
1
.
3. Disconnect the control medium line and remove any ac-
cessories fitted from the pneumatic stainless steel actu-
ator
A
.
4. Undo the bolts between the mounting plate
4
and the
housing
5
.
5. Pull the pneumatic stainless steel actuator
A
downwards
through the recess of the housing
5
.
Содержание SUPM SUMONDO