GEM RP60 Скачать руководство пользователя страница 4

❏ 

❏ 

❏ 

❏ 

❏ 

4

RP60 TEST PROCEDURE (761194 Cpu board)

This  procedure  are  not  intended  to  repair  a  fault  but  only  to  check  the  proper
instrument  operations  after  a  repairing  execution.  The  procedures  that  follow  must
be  executed  in  the  order  specified.

Instrument and Tools

1)

Dual  trace  oscilloscope.

2)

Sinusoidal  signal  generator.

3)

Digital  Multimeter.

4)

Midi  cable.

5)

N.1  stereo  jack  plug.

6)

N.2  mono  jack  plug.

Setup

l

Connect  the  stereo  jack  to  the  PHONES  2  output.

l

Connect  the  mono  jack  to  the  LEFT  and  RIGHT  OUTPUTS.

l

Check  jumper  positions:  for  RP60  none  must  be  shorted.

Supplies Check

l

Check  with  the  Multimeter  the  following  voltages  on  Power  Amplifier  &  Supply
Board:
CN7  pin1-2  =  32±5Vac
CN8  pin1-2  =  26±4Vac
CN6  pin1-6  =  -12Vdc
CN6  pin2-6  =  +12Vdc
CN11  pin4-6  =  +5Vdc

Memory and System Reset

l

To  Re-set  the  instrument  press  the  two  SOUND/DATA  buttons  while  holding
pressed  the  GRAND  PIANO  button.
This  operation  clear  all  data  in  memory.

Speakers Check

l

Press  and  hold  A6  note  key  and  then  SOUND/DATA  UP  button:  Playing  a
note  (OBOE  preset)  it  must  be  heard  from  right  speaker.

l

Press  and  hold  G6  note  key  and  then  SOUND/DATA  UP  button:  Playing  a
note  (OBOE  preset)  it  must  be  heard  from  left  speaker.

Right & Left Output Levels Check

Check  the  levels  as  follow:

l

Connect  the  two  traces  of  the  oscilloscope  to  the  tip  and  ring  contacts  and
the  ground  clip  to  the  sleeve  of  the  stereo  jack  plugged  into  PHONES  2,
set  it  at  2ms/div.  5V/div.

l

Set  the  Volume  at  Max.

l

Press  and  hold  B6  note  key  and  then  SOUND/DATA  UP  button:  Play  the  C5
note  (OBOE  preset)  with  the  maximum  dynamic,  the  note  must  be  heard
from  each  speaker  without  distortions  or  oscillations,  the  level  displayed  on
the  oscilloscope  screen  must  be  22Vpp±1Vpp.

l

Connect  the  first  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts  of
the  mono  jack  plugged  into  RIGHT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Connect  the  other  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts
of  the  stereo  jack  plugged  into  LEFT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Move  the  stereo  jack  from  PHONES  2  to  PHONES  1.

l

Press  and  hold  B6  note  key  and  then  SOUND/DATA  UP  button:  Play  the  C5
note  (OBOE  preset)  with  the  maximum  dynamic,  the  level  displayed  on  the
oscilloscope  screen  must  be  1.6Vpp±0.1Vpp.

Right & Left Inputs Levels Check

Check  the  levels  as  follow:

l

Set  the  sinusoidal  generator  at  1KHz  400mVpp.

l

Connect  the  generator  to  the  RIGHT  INPUT.

l

Set  the  oscilloscope  at  2ms/div.  0.1V/div.

l

A  sinusoidal  signal  of  620±50mVpp  must  be  showed  on  the  scope  screen.

l

Also  check  the  LEFT  INPUT.

Pedals Check

l

Plug  in  the  switch  pedals  to  the  PEDALS  DIN  socket,  press  down  the  DAMPER
pedal  (right)  and  then  press  a  note  key:  the  instrument  plays  the  note,
release  the  note  key  and  the  sound  holds  on,  release  the  pedal  and  the
sound  shuts  off.

l

Press  a  note  key  while  pressing  the  SOFT  pedal  (left)  the  sound  is  more
soft.

Midi In/Out Check

l

Set  the  Local  Off  pressing  and  holding  B7  note  key  and  then  SOUND/DATA
DOWN  button.

l

Playing  some  notes  you  do  not  hear  sound,  connect  the  midi  cable  between
MIDI  IN  and  OUT  sockets,  play  again  and  now  the  instrument  sound.

l

Restore  the  Local  On  pressing  and  holding  B7  note  key  and  then  SOUND/
DATA  UP  button.

Reliability Check

Before  reassembling  the  instrument  and  before  deliver  it  to  the  user,  it  is  a
goal  verify  its  reliability:
To  do  that  switch  it  off,  or  leaving  it  switched  on  but  operating  with  greatest
caution,  carefully  shake  the  boards  and  connections  inside  it  using  an  insulated
tool  (for  example  the  handle  of  the  screwdriver)  to  find  wrong  contacts  and
so  on.
Turn  on  the  instrument  and  verify  that  it  operates  correctly.
Start the Demo pressing SOUND/DATA DOWN and SOUND/DATA UP simultaneously,
finally  leave  it  switched  on  for  a  long  time  verifing  its  functionality  occasionnally.

RP80 TEST PROCEDURE (761201 Cpu Board)

This  procedure  are  not  intended  to  repair  a  fault  but  only  to  check  the  proper
instrument  operations  after  a  repairing  execution.  The  procedures  that  follow  must
be  executed  in  the  order  specified.

Instrument and Tools

1)

Dual  trace  oscilloscope.

2)

Sinusoidal  signal  generator.

3)

Digital  Multimeter.

4)

Midi  cable.

5)

N.1  stereo  jack  plug.

6)

N.2  mono  jack  plug.

Setup

l

Connect  the  stereo  jack  to  the  PHONES  2  output.

l

Connect  the  mono  jack  to  the  LEFT  and  RIGHT  OUTPUTS.

l

Check  jumper  positions:  the  jumper  J2  must  be  shorted.

Supplies Check

l

Check  with  the  Multimeter  the  following  voltages  on  Power  Amplifier  &  Supply
Board:
CN7  pin1-2  =  32±5Vac
CN8  pin1-2  =  26±4Vac
CN6  pin1-6  =  -12Vdc
CN6  pin2-6  =  +12Vdc
CN11  pin4-6  =  +5Vdc

Memory and System Reset

l

To  Re-set  the  instrument  press  the  two  SOUND/VAR.  buttons  while  holding
pressed  the  GRAND  PIANO  button.
This  operation  clear  all  data  in  memory.

Control Panel Check

l

Press  all  buttons  on  controls  panel  verifying  that  the  relative  led  lights  up,
for  the  switch  without  led  the  display  shows  their  function  accordingly.

Speakers Check

l

Press  and  hold  A6  note  key,  then  GRAND  PIANO  and  TEMPO/DATA+  buttons:
Playing  a  note  (OBOE  preset)  it  must  be  heard  from  right  speaker.

l

Press  and  hold  G6  note  key,  then  GRAND  PIANO  and  TEMPO/DATA+  buttons:
Playing  a  note  (OBOE  preset)  it  must  be  heard  from  left  speaker.

Right & Left Output Levels Check

Check  the  levels  as  follow:

l

Connect  the  two  traces  of  the  oscilloscope  to  the  tip  and  ring  contacts  and
the  ground  clip  to  the  sleeve  of  the  stereo  jack  plugged  into  PHONES  2,
set  it  at  2ms/div.  5V/div.

l

Set  the  Volume  at  Max.

l

Press  and  hold  B6  note  key,  then  GRAND  PIANO  and  TEMPO/DATA+  buttons:
Play  the  C5  note  (OBOE  preset)  with  the  maximum  dynamic,  the  note  must
be  heard  from  each  speaker  without  distortions  or  oscillations,  the  level
displayed  on  the  oscilloscope  screen  must  be  22Vpp±1Vpp.

l

Connect  the  first  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts
of  the  mono  jack  plugged  into  RIGHT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Connect  the  other  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts
of  the  stereo  jack  plugged  into  LEFT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Move  the  stereo  jack  from  PHONES  2  to  PHONES  1.

l

Press  B6  note  key,  then  GRAND  PIANO  and  TEMPO/DATA+  buttons:  Play  the
C5  note  (OBOE  preset)  with  the  maximum  dynamic,  the  level  displayed  on
the  oscilloscope  screen  must  be  1.6Vpp±0.1Vpp.

Right & Left Inputs Levels Check

Check  the  levels  as  follow:

l

Set  the  sinusoidal  generator  at  1KHz  400mVpp.

l

Connect  the  generator  to  the  RIGHT  INPUT.

l

Set  the  oscilloscope  at  2ms/div.  0.1V/div.

l

A  sinusoidal  signal  of  620±50mVpp  must  be  showed  on  the  scope  screen.

l

Also  check  the  LEFT  INPUT.

Pedals Check

l

Plug  in  the  switch  pedals  to  the  PEDALS  DIN  socket,  press  down  the  DAMPER
pedal  (right)  and  then  press  a  note  key:  the  instrument  plays  the  note,
release  the  note  key  and  the  sound  holds  on,  release  the  pedal  and  the
sound  shuts  off.

l

Press  a  note  key  while  pressing  the  SOFT  pedal  (left)  the  sound  is  more
soft.

Midi In/Out Check

l

Set  the  Local  Off  pressing  and  holding  B7  note  key  and  TEMPO/DATA-  button.

l

Playing  some  notes  you  do  not  hear  sound,  connect  the  midi  cable  between
MIDI  IN  and  OUT  sockets,  play  again  and  now  the  instrument  sound.

l

Restore  the  Local  On  pressing  and  holding  B7  note  key  and  TEMPO/DATA+
button.

Reliability Check

Before  reassembling  the  instrument  and  before  deliver  it  to  the  user,  it  is  a
goal  verify  its  reliability:
To  do  that  switch  it  off,  or  leaving  it  switched  on  but  operating  with  greatest
caution,  carefully  shake  the  boards  and  connections  inside  it  using  an  insulated
tool  (for  example  the  handle  of  the  screwdriver)  to  find  wrong  contacts  and
so  on.
Turn  on  the  instrument  and  verify  that  it  operates  correctly.
Start  the  Demo  pressing  SOUND/VAR-  and  SOUND/VAR+  simultaneously,  finally
leave  it  switched  on  for  a  long  time  verifing  its  functionality  occasionnally.

RP60/70 TEST PROCEDURE (761216 Cpu Board)

This  procedure  are  not  intended  to  repair  a  fault  but  only  to  check  the  proper
instrument  operations  after  a  repairing  execution.  The  procedures  that  follow  must
be  executed  in  the  order  specified.

Instrument and Tools

1)

Dual  trace  oscilloscope.

2)

Sinusoidal  signal  generator.

3)

Digital  Multimeter.

4)

Midi  cable.

5)

N.1  stereo  jack  plug.

6)

N.2  mono  jack  plug.

Setup

l

Connect  the  stereo  jack  to  the  PHONES  2  output.

l

Connect  the  mono  jack  to  the  LEFT  and  RIGHT  OUTPUTS.

l

Check  jumper  positions:  the  jumper  J3  must  be  shorted.

Supplies Check

l

Check  with  the  Multimeter  the  following  voltages  on  Power  Amplifier  &  Supply
Board:
CN7  pin1-2  =  32±5Vac
CN8  pin1-2  =  26±4Vac
CN6  pin1-6  =  -12Vdc
CN6  pin2-6  =  +12Vdc
CN11  pin4-6  =  +5Vdc

Memory and System Reset

l

To  Re-set  the  instrument  press  the  two  SOUND/DATA  buttons  while  holding
pressed  the  GRAND  PIANO  button.
This  operation  clear  all  data  in  memory.

Speakers Check

l

Press and hold A6 note key, then GRAND PIANO and SOUND/DATA UP buttons:
Playing  a  note  (OBOE  preset)  it  must  be  heard  from  right  speaker.

l

Press and hold G6 note key, then GRAND PIANO and SOUND/DATA UP buttons:
Playing  a  note  (OBOE  preset)  it  must  be  heard  from  left  speaker.

Right & Left Output Levels Check

Check  the  levels  as  follow:

l

Connect  the  two  traces  of  the  oscilloscope  to  the  tip  and  ring  contacts  and
the  ground  clip  to  the  sleeve  of  the  stereo  jack  plugged  into  PHONES  2,
set  it  at  2ms/div.  5V/div.

l

Set  the  Volume  at  Max.

l

Press and hold B6 note key, then GRAND PIANO and SOUND/DATA UP buttons:
Play  the  C5  note  (OBOE  preset)  with  the  maximum  dynamic,  the  note  must
be  heard  from  each  speaker  without  distortions  or  oscillations,  the  level
displayed  on  the  oscilloscope  screen  must  be  22Vpp±1Vpp.

l

Connect  the  first  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts
of  the  mono  jack  plugged  into  RIGHT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Connect  the  other  trace  of  the  oscilloscope  to  the  tip  and  sleeve  contacts
of  the  stereo  jack  plugged  into  LEFT  OUTPUT,  set  it  at  2ms/div.  0.2V/div.

l

Move  the  stereo  jack  from  PHONES  2  to  PHONES  1.

l

Press and hold B6 note key, then GRAND PIANO and SOUND/DATA UP buttons:
Play  the  C5  note  (OBOE  preset)  with  the  maximum  dynamic,  the  level
displayed  on  the  oscilloscope  screen  must  be  1.6Vpp±0.1Vpp.

Right & Left Inputs Levels Check

Check  the  levels  as  follow:

l

Set  the  sinusoidal  generator  at  1KHz  400mVpp.

l

Connect  the  generator  to  the  RIGHT  INPUT.

l

Set  the  oscilloscope  at  2ms/div.  0.1V/div.

l

A  sinusoidal  signal  of  620±50mVpp  must  be  showed  on  the  scope  screen.

l

Also  check  the  LEFT  INPUT.

Pedals Check

l

Plug  in  the  switch  pedals  to  the  PEDALS  DIN  socket,  press  down  the  DAMPER
pedal  (right)  and  then  press  a  note  key:  the  instrument  plays  the  note,
release  the  note  key  and  the  sound  holds  on,  release  the  pedal  and  the
sound  shuts  off.

l

Press  a  note  key  while  pressing  the  SOFT  pedal  (left)  the  sound  is  more
soft.

Midi In/Out Check

l

Set  the  Local  Off  pressing  and  holding  B7  note  key  and  then  SOUND/DATA
DOWN  button.

l

Playing  some  notes  you  do  not  hear  sound,  connect  the  midi  cable  between
MIDI  IN  and  OUT  sockets,  play  again  and  now  the  instrument  sound.

l

Restore  the  Local  On  pressing  and  holding  B7  note  key  and  then  SOUND/
DATA  UP  button.

Reliability Check

Before  reassembling  the  instrument  and  before  deliver  it  to  the  user,  it  is  a
goal  verify  its  reliability:
To  do  that  switch  it  off,  or  leaving  it  switched  on  but  operating  with  greatest
caution,  carefully  shake  the  boards  and  connections  inside  it  using  an  insulated
tool  (for  example  the  handle  of  the  screwdriver)  to  find  wrong  contacts  and
so  on.
Turn  on  the  instrument  and  verify  that  it  operates  correctly.
Start the Demo pressing SOUND/DATA DOWN and SOUND/DATA UP simultaneously,
finally  leave  it  switched  on  for  a  long  time  verifing  its  functionality  occasionnally.

Отзывы: