4. The inside diameter of the piping must match the nominal
diameter of the GEMÜ product.
5. The diameter of the pipe flanges should be, in compliance
with the respective nominal size, between "D max" and "D
min" (see table).
Flange
Flange
Dia. D min
Dia. D max
Butterfly valve
Shut-off seal
DN
D max
D min
25
32
13
40
47
29
50
60
33
65
74
53
80
96
72
100
113
92
125
140
118
150
169
146
200
223
197
250
273
247
300
323
297
350
363
335
400
417
384
450
465
432
500
518
485
600
618
580
Dimensions in mm
10.3 Installation of the standard version
CAUTION
Damage!
▶
Before carrying out any welding on the piping, remove the
butterfly valve to prevent damage to the liner.
1. Shut off plant or plant component.
2. Secure against recommissioning.
3. Depressurize the plant or plant component.
4. Completely drain the plant or plant component and allow it
to cool down until the temperature is below the media va-
porization temperature and cannot cause scalding.
5. Decontaminate, rinse and ventilate the plant or plant com-
ponent properly.
6. Check flange faces for potential damage.
7. Remove any rough areas (rust, dirt, etc.) from the pipe
flanges.
8. Sufficiently spread the pipe flanges.
9. Do not use any flange seals.
10. Clamp the butterfly valve
1
centrally between the pipes
with flanges
2
and
3
.
1
3
2
11. Slightly open the butterfly valve
1
. The disc must not pro-
ject from the body.
12. Insert bolts
4
in all holes in the flange.
10 Installation in piping